Sony HKC-7080 Installation And Maintenance Manual page 30

Ccd modification unit for sony hdc-700
Table of Contents

Advertisement

3-1. Setup Menu
3-1-2. Paint Menu
Page
Ver.
Item
Knee 1
Point R/G/B/M
Slope R/G/B/M
W.CLP R/G/B/M
Knee
Auto Knee
White Clip
Test
Clear
Knee 2
Knee Saturation
Knee SAT Level
Super Skin Knee
Test
Clear
Detail 1
Detail
Level
Limiter
Crispening
H/V Ratio
Frequency
Level DEP
Level DEP
Clear
3-8 (E)
Settings
_99 to 99 ([0])
_99 to 99 ([0])
_99 to 99 ([0])
[On], Off
On, [Off]
[On], Off
[Off], 1, 2
Throw MENU SELECT
switch to ENTER to execute
On, [Off]
_99 to 99 ([_99])
On, [Off]
[Off], 1, 2
Throw MENU SELECT
switch to ENTER to execute
[On], Off
_99 to 99 ([_60])
_99 to 99 ([0])
_99 to 99 ([_25])
_99 to 99 ([0])
_99 to 99 ([0])
_99 to 99 ([25])
[On], Off
Throw MENU SELECT
switch to ENTER to execute
Contents
Adjusts the R, G, B or master knee point level when the auto
knee function is turned off
Adjusts the R, G, B or master knee slope level when the auto
knee function is turned off
Adjusts the R, G, B or master white clip level
Turns the knee correction circuit on and off
Turns the auto knee function on and off
Turns the white clip function on and off
Selects the TEST signal
Off: No test signal is output
1:
Outputs the sawtooth waveform test signal
2:
Outputs the 3-step waveform test signal
Resets numeric settings on the Knee 1 page to 0
(When you throw MENU SELECT switch to ENTER, the "Clear"
indication flashes. Throw MENU SELECT switch to ENTER
again to execute; throw to CANCEL to cancel)
Turns the knee saturation function on and off
Adjusts the knee saturation level
Turns on and off the function to improve the color reproduction
of a skin color in a highlight shot scene
Selects the TEST signal
Off: No test signal is output
1:
Outputs the sawtooth waveform test signal
2:
Outputs the 3-step waveform test signal
Resets numeric settings on the Knee 2 page to 0
(When you throw MENU SELECT switch to ENTER, the "Clear"
indication flashes. Throw MENU SELECT switch to ENTER
again to execute; throw to CANCEL to cancel)
Turns on and off the function to improve resolution by adding
the detail signal
Adjusts the master level for the detail signal
Adjusts the clipping level against the maximum detail level
Adjusts the level at which the detail signal is crispened
Adjusts the mix ratio of H and V detail signals
Adjusts the boost frequency for H detail signal
Adjusts the level to control the detail signal used at lower signal
level
Turns the level dependence function on and off
Resets numeric settings on the Detail 1 page to 0
(When you throw MENU SELECT switch to ENTER, the "Clear"
indication flashes. Throw MENU SELECT switch to ENTER
again to execute; throw to CANCEL to cancel)
HKC-7080

Advertisement

Table of Contents
loading

Table of Contents