Daikin RKS42G2V1B Service Manual page 5

Outdoor unit removal procedure
Hide thumbs Also See for RKS42G2V1B:
Table of Contents

Advertisement

Si001070
Step
2
Remove the 2 screws
to remove the top
panel, and 7 screws to
remove the front panel.
Remove the 4 screws
3
and remove the
discharge grille.
4
Remove the screw and
remove the stop valve
cover.
Removal Procedure
Procedure
Top panel
Hooks
Discharge grille
Hooks
(R12305)
Front panel
(R9364)
Stop
valve
cover
(R8139)
Shield plate
(R12213)
Removal of Outer Panels
Points
The front panel has 4 hooks.
When reassembling, make
sure to fit the 4 hooks.
The stop valve cover is
united with the shield plate.
When reassembling, make
sure to fit the 5 hooks.