  • Page 1 Profi-Line: AS 40 The modular premium product - Installation...
  • Page 2: Safety Notes

    S0 bus that you are also al- lowed to operate directly on the ISDN The telephone system has a general connec- network. Two digital AGFEO system tel- tion permit (Germany: AAE). Safety notes ¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢ - The telephone system conforms...
  • Page 3: Installation

    Installation Checking the scope of delivery ¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢ - 1 Telephone system with plugged-in - 1 Instruction manual connection module - 1 Installation manual - 1 Set of securing material (3 dowels S6, 3 - 2 Short-form operating instructions for wood screws (cross head recess) 4 x 40) system telephones - 1 Bolt (module extractor) - 3 Short-form operating instructions...
  • Page 4 Opening the housing ¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢ Before opening the housing, remove the 230 V mains plug from the telephone system. Removing the cover - Pull the edge of the cover down slightly to - Grip the underside behind the finned unlatch it. Detach the cover towards you. cover that covers the telephone system’s The cover is not locked in the as-delivered connection panel.
  • Page 5 Safety notes ¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢ Pay attention to the safety notes telephone system, the network termi- - before installing or removing a module, nator (NT) or the S0 bus. - before connecting or disconnecting a connecting lead 3. Touch the metal shield of the PC/ printer socket on the bottom of the tel- 1.
  • Page 6 The connection module The connection module belongs to the basic switch S1301 telephone system. ab/cd Fixed slot X=0 (outside right). The con- nection module must not be plugged on to any other slot as otherwise the con- nector will be damaged. Interfaces 1 External S0 interface S0 0/1 (ISDN basic access as a point-to-multipoint or point-...
  • Page 7 Connecting analog users ¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢ You may connect all analog terminals to the System telephones telephone system that you are also allowed Connect system telephones by four wires to to operate on the public telecommunica- the Vario ports by connecting them to the tions network.
  • Page 8 S0 access of the tel- b2 - white ephone system. ISDN terminals: - To separate a connection, use a suitable - AGFEO system telephones digital tool (screwdriver with narrow blade) to - ISDN telephones press down the terminal spring and pull - ISDN cards out the wire.
  • Page 9 Termination for the internal S0 access - Strip 11 mm off the wires - Push the individual wires into the terminal You must terminate the internal S0 access. until they move no further without press- Wire the last IAE / UAE connection socket ing the terminal spring.
  • Page 10 The T Module 404 (User module) The T Module 404 features 4 interfaces (Vario ports) for system telephones or a/b terminals. Slots: X=1 - 4, freely optional Connecting analog users You may connect all analog terminals to the telephone system that you are also permit- ted to operate on the public telecommuni- cations network.
  • Page 11 The S0 Module 420 The S0 module features the following inter- faces: 1 External S0 interface S0 X/1(ISDN basic ac- cess as a point-to-multipoint or point-to- point connection) Schalter S202 Schalter 1 Switchable internal / external S0 interface S201 S0 X/2 (external: ISDN basic access as a point-to- multipoint or point-to-point connection, internal: point-to-multipoint connection)
  • Page 12 External S0 connection, fixed S0 X/1 (Western socket) ¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢ Terminators for external S0 access S0 X/1 Connection to a point-to-point For the point-to-multipoint connection, the connection two switches S4101 for the 100 Ohm termi- You can only connect one ISDN telephone nators must be : system to an ISDN point-to-point connec- - closed if the external S0 connection is...
  • Page 13 Terminal a1 - green wire system. b1 - brown ISDN terminals: a2 - yellow - AGFEO system telephones digital b2 - white - ISDN telephones - To separate a connection, use a suitable - ISDN cards tool (screwdriver with a narrow blade) to...
  • Page 14 Terminator for the internal S0 access - To separate a connection, use a suitable tool (screwdriver with a narrow blade) to You must terminate the internal S0 access. press down the terminal spring and pull Wire the last IAE / UAE socket with the two out the wire.
  • Page 15 The TFE Module 402 (door hands free unit) The TFE module 402 features two interfaces telephone system supports one bell button. conforming to the 4-wire TFE specification Optionally, a loudspeaker system or an audio FTZ 123 D12 for the connection of door sta- module can be connected to the FTZ 123 tions with amplifiers.
  • Page 16 The TFE Module 403 (door hands free unit) The TFE module 403 features an interface It features an interface (TFE 2) conforming (TFE 1) that conforms to the Telekom 2-wire to the 4-wire TFE specification FTZ 123 D12 TFE (CE interface) specification for connect- for connecting door stations with amplifiers.
  • Page 17 Connecting the door hands free unit (TFE) ¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢ TFE Module 402 The TFE module 403 also has an interface The TFE module 402 features two interfaces (TFE 2) that conforms to the 4-wire TFE conforming to the 4-wire TFE specification specification FTZ 123 D12 for the connec- FTZ 123 D12 for the connection of door tion of door stations with amplifiers.
  • Page 18 Switching relays ¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢ You can make versatile use of the relays on TFE Module 403 the TFE module either to connect a door Instead of the door hands free unit TFE 2 in hands free unit or as individual switching conformity with FTZ 123 D12, you can use relays with potential-free contacts for other the relays TO and TS for other tasks.
  • Page 19 Connecting an audio module ¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢ D12 interface for announcements. A loudspeaker system or an audio module can be optionally connected to the FTZ 123 KT´ NF´ TFE2 TFE1 TS2 TS1 SPK1 SPK2 TFE Module 402 or 403 Audio module AM 20 Figure 12: Connecting an audio module Connecting external music on hold (MoH) ¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢...
  • Page 20 Connecting a printer for printing connection charges ¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢ To print out connection records, the printer You can connect any printer to the telephone must be on all the time and must be con- system’s RS 232C interface to print out con- nected to the telephone system.
  • Page 21 Closing the housing ¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢ Replacing the cover Locking the cover - First hook in the cover at the top of the - Insert the bolt with the hook facing housing. The three latches engage behind downwards in the cover opening, turning the edge of the housing.
  • Page 22 Commissioning You have installed the telephone system. - Once the telephone system has been Now, only a few operations are necessary switched on, you can immediately make before you are able to make telephone calls. internal and external telephone calls. When an external subscriber calls, all con- - Connect terminals.
  • Page 23 As-delivered state The followings settings are active in the as- - Connection record printing: off for all delivered state: users - The switches S130 /S01 (termination for - Dialled phone number printing: none the external S0 access) are closed and the 100 Ohm terminators are on.
  • Page 24: Technical Data

    Technical data Specification Modular ISDN telecommunications system with 4 module slots Basic capacity 1 external S0 access (point-to-point or point-to-multipoint connection) One internal/external S0 access 2 Vario ports (optionally 2 system telephones or 2 a/b terminals) 1 a/b terminal Expansion modules - T module 404 4 Vario ports (optionally 4 system telephones or 4 a/b terminals)
  • Page 25 Analog terminals - Range System telephones 2 x 75 Ohm (Ø 0.6 mm, 1200 m) - Connection a/b terminals: 2 x 50 Ohm (Ø 6 mm, 800 m), symmetric System telephones connected by 4 wires and a/b units connected by two wires via a spring terminal connection - Dialling method Pulse dialling or DTMF - Inquiry key...
  • Page 26 This documentation was elaborated with great care and attention and is revised on a You can only use the numerous ISDN features of your AGFEO-ISDN telephone system if your network operator has provided you with these features.
  • Page 27 DTMF dialing, ISDN - What telephone system do you have? telephones, fax machines etc.) - E.g. AGFEO AS 40 (on the type plate of - Keep the operating instructions of the the system) connected terminals and this manual at - What connection type (PTP and/or PTMP) the ready.
  • Page 28 Telecommunications equipment 73/23/EWG Low-voltage devices 89/336/EWG Electromagnetic compatibility This is why your telephone system bears the CE mark. Ident. No. 529 435 AGFEO GmbH & Co. KG Modifications and errors reserved. Gaswerkstr. 8 Printed in Germany D-33647 Bielefeld 0991 Internet: http://www.agfeo.de...