Summary of Contents for AGFEO Basic-Line plus Series

  • Page 1 Basic-Line plus: AS 140, AS 141 AS 190, AS 191 - Installation 1 - 1...
  • Page 2: Safety Notes

    S0 bus (AS 141/191) that you are also allowed to operate directly on the The telephone system has a general connec- ISDN network. Two digital AGFEO system tion permit (Germany: AAE). Safety notes ¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢ - The telephone system conforms...
  • Page 3: Installation

    - 1 ISDN connecting cable (IAE-IAE), 1.5 m TK-Set, TK-LCR, TK-Bill, TK-Phone and TK- - 1 PC connecting cable Timer. - 1 Drilling jig On our homepage "www.agfeo.de", you - 1 Instruction package including instruction may find the operating manuals for manual, installation manual, short-form download.
  • Page 4 Opening the housing ¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢ - Reach behind the cover on the bottom - Pull the edge of the cover down slightly so which covers the housing of the telecom- that the cover snaps out. munications system. Remove the cover to the front. PC/Printer (RS 232) (D-Sub 9-pin socket) Internal ISDN connection...
  • Page 5 Securing the housing ¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢ - Use the enclosed template to draw the - Hammer in the plug flush with the wall three drill holes. - Turn the two top screws in until the screw - When drawing the drill holes, make sure head is about 8 mm from the wall.
  • Page 6 Drawing 2: Pin assignments 1 - 6...
  • Page 7 Connecting analog users ¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢ You may connect all analog terminals to the of the analog ports AS 190/191:Ports 1 to 8, telephone system that you are also permit- AS 140/141: Ports 1 to 4 (see drawing 2). ted to operate on the analog telecommuni- cations network.
  • Page 8 4 wire screw clip. ISDN terminals: You need the following material to install an - AGFEO system telephones digital internal S0 port: - ISDN telephones - Telecommunications cable; we recom- - ISDN cards mend the cable type I-Y (St) Y 2 x 2 x 0.6...
  • Page 9 Connecting a door hands free unit (TFE, AS 190/191) ¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢ TFE - interface conforming to the 4-wire TFE tial-free relay contacts T0 (R 1) and T0´. specification FTZ 123 D12 for the connec- Maximum contact load-carrying capacity: tion of door stations with amplifiers. 30 VDC/1 A or 123 VAC/0.5 A.
  • Page 10 Switching relays ¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢ You can put the relays to diverse use as indi- nal or external telephone. You can also as- vidual switching relays R1 and R2 for other sign internal phone numbers to the relays in functions. For example, you can use them to order to include them in the ringing distribu- connect a door hands free unit (TFE), an ad- tion settings, e.g.
  • Page 11 Connecting a printer for printing connection charges ¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢ To print out connection records, the printer You can connect any printer to the tel- must be on all the time and must be con- ephone system’s RS 232C interface to print nected to the telephone system.
  • Page 12 Commissioning You have installed the telephone system. - Once the telephone system has been Now, only a few operations are necessary switched on, you can immediately make before you are able to make telephone calls. internal and external telephone calls. When an external subscriber calls, all con- - Connect terminals.
  • Page 13 As-delivered state The followings settings are active in the as- - Door call variant 2 (night): off, Printout of delivered state: dialed phone number: without - Automatic dialing: off - The switches S500 /S501 (termination for the external S0 access) are closed and the - Printout of connection data set: off for all 100 Ohm terminators are on.
  • Page 14: Technical Data

    Technical Data Specification AS 140, AS 190: ISDN telecommunications system without internal S0 access, internal S0 access by S0 module AS 110 can be retrofit- ted. AS 141, AS 191: ISDN telecommunications system with internal S0 access, internal S0 access equipped ex-factory with S0 module AS Housing dimensions 32.2 x 24.4 x 8.1 cm (width x height x depth) Weight...
  • Page 15 PC/printer interface similar to RS 232C - Range / level 3 m/ +/- 5 V - Connection 9pin D-Sub socket Feed in of external Music e.g. by controllable headphones output of a cassette or CD player on Hold 10 kohm, asymmetrical - Input impedance max.
  • Page 16 Telecommunications equipment 73/23/EWG Low-voltage devices 89/336/EWG Electromagnetic compatibility This is why your telephone system bears the CE mark. Ident. No. 529 249 AGFEO GmbH & Co. KG Modifications and errors reserved. Gaswerkstr. 8 Printed in Germany D-33647 Bielefeld 1991 Internet: http://www.agfeo.de...