32 channel telemetry for rotating applications with signal conditioning for stg and icp signal bandwidth 32x 3000hz incl. inducting powering and ir-link
Digital high data rate telemetry system for strain gage and icp applications on rotating shafts (21 pages)
Summary of Contents for KMT CTP32-Rotate-IR
Page 1
KMT - Kraus Messtechnik GmbH Gewerbering 9, D-83624 Otterfing, Germany, 08024-48737, Fax. 08024-5532 Home Page http://www.kmt-telemetry.com, Email: info@kmt-telemetry.com User Manual INSTRUCTIONS FOR QUALIFIED PERSONNEL ONLY!
Page 2
CTP32-Rotate - Technical Data: Front side Rear side Encoder (Rotor Electronic) Decoder / IND-PWR Number of channels: Number of channels: STG ≥ 350Ω or ICP Sensor support Analog Output +/-10V via 37-Sub-D connector Excitation STG 4V, ICP 4mA (1mA) Digital Output PCM serial (optional PCM interface for PC) Gain...
CTP32-PCM-DEC Receiver unit for up to 32 Channels output via 37 pol. Sub D incl. inductive power generator Front side view Rear side view Female 37 pole Sub-D for analog signal output, CH 1 to 32 Power ON LED Power Switch Transmission error LED Fuse of powering defect LED 7-pole female TUCHEL connector for...
Page 4
SET of CTP32-Rotate CTP32 ENCODER CTP32-DEC with POWER/ DATA cable5m Optional with IND-PWR and integrated BNC32-BOX (up to 25m on request) IR-transmission IND-power supply 32x Sensor LAN Adapter with Cover lifter DC power cable LAN cross over cable tool cable Version 2012-11 Technical Data are subject to change without notice!
Page 5
Connections: 32 Channel CTP32-Rotate ENC IP-LAN Setup socket Stator arm Static part for fixing POWER/ DATA cable to DEC Rotating part Version 2012-11 Technical Data are subject to change without notice!
Page 6
Open housing: 32 Channel CTP32-Rotate ENC Untwist the M2.5 screw Lift the cover on the slot with with hexagon screw driver 2mm cover lifter tool! Take care with power and data cables!! O-ring seal is lubricated with silicone grease! Open the modules ring Now you can change the acquisition modules e.g.
Page 7
CTP-STG - Acquisition module for 2 channels strain gages CTP-STG Acquisition module for 2x strain gages Full and half bridge (≥350) Fixed excitation 4V DC Offset calibration by auto zero Gain: 250-500-1000-2000 Anti aliasing filter Signal bandwidth 0Hz to 3000Hz Resolution 16bit Accuracy <0.2% Powering: 6.5-9V DC...
Page 8
CTP-ICP - Acquisition module for 2 channels ICP CTP-ICP Acquisition module for 2x ICP Fixed excitation 4mA or 1mA Gain: 1-2-4-8-16 Anti aliasing filter Resolution 16bit Accuracy <0.2% Powering: 6.5-9V DC Current consumption 80mA IPC connection Powering and for 2 channels digital bus I/O IN + IN -...
Page 9
Settings CTP-Rotate-ENC Programmable via web interface Web interface address: IP 192.168.0.110 Settings: Gain 125-250-500-1000-2000 Half- and full bridge Make Auto Zero YES/NO Gain 1-2-4-8-16 Selectable for each channel! Data / Power Stator arm cable OUT for fixing CTP32-Rotate-ENC Programming plug Programming socket LAN Adapter...
Page 10
Settings of CTP-Rotate-ENC Programmable via web interface Data / Power CTP32-Rotate-ENC Stator arm cable OUT for fixing Programming plug LAN Adapter 1) Power ON the CTP-Rotate ENC via IND-PWR of CTP-Rotate-DEC 2) Connect the LAN-Adapter with the CTP-Rotate-Encoder 3) Adjust your notebook to manual on e.g. IP 192.168.0.100 4) Connect LAN-Adapter with your notebook via cross-over LAN cable 5) Open Microsoft Internet Browser and enter IP address 192.168.0.110 of LAN-Adapter...
CTP-MTP Software setup DOWNLOAD parameters for device GAIN setting Select gain of 125-250-500-1000 or 2000 by popup window You can download your stored parameters from the CTP-Rotate-ENC BRIDGE setting AUTO-ZERO setting Select Auto-Zero per channel. The Auto-Zero function will be executed only one time per upload the parameters to CTP-...
Page 12
Dimensions of CTP32-Rotate-ENC 135mm 250mm 280mm 45° Bolt circle 265mm 280mm Hole diameter 6.2mm Weight 3950g (without cables) Version 2012-11 Technical Data are subject to change without notice!
Need help?
Do you have a question about the CTP32-Rotate-IR and is the answer not in the manual?
Questions and answers