Commissioning - Wickes Aquatronic 4 Ultra Installation And Operating Instructions Manual

Electric shower
Table of Contents

Advertisement

Fig.
Valve
spindle
T00390
Fig.
Temperature control set
at minimum flow setting
Aquatronic 4 Ultra electric shower
>POM-GF30<

COMMISSIONING

Commissioning
WARNING!
Before normal operation of the
W-001-A
shower, it is essential the following
commissioning procedure is completed
correctly.
At this stage, temporarily fit the cover in order to
carry out the commissioning procedure.
The first operation of the shower is intended to
flush out any remaining unit debris and to make
sure the heater unit contains water before the
elements are switched on.
Refit the trimplate.
Turn the valve spindle fully clockwise until the
spindle hits the 'stop' (fig.). DO NOT force
the spindle.
Turn the temperature control on the cover to the
minimum flow position (fig.).
Offer the cover to the unit.
IMPORTANT!
Do not connect the 10-way ribbon
cable at this stage.
Carefully locate the cover onto the backplate
and make sure the wires are not trapped.
Guide the cover into position so that the control
spindle locates correctly (minor adjustment may
be necessary to align the control and spindle).
Should any difficulty arise, recheck the points
above.
While applying slight pressure to the front
cover, secure in position with the three retaining
screws.
Fit the flexible hose to the shower outlet making
sure the outlet of the hose is directed to waste.
Check the supplied sealing washer is in place.
Do NoT attach the showerhead at this stage.
Before turning on the electric and mains
water supplies to the shower, make sure the
temperature control is rotated fully clockwise to
'HOT', the minimum flow position (fig.).
note: Failure to rotate the valve spindle fully
clockwise may cause the PRD to operate.

I-004-A

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for Wickes Aquatronic 4 Ultra

Table of Contents