AV32L5EKGY AV32L5EIGY SPECIFICATIONS CONTENTS Item AV32L5EKGY AV32L5EIGY Dimensions ( W× × × × H× × × × D ) 855mm × 550mm × 568mm Mass 54.2kg CCIR I CCIR B/G, I, D/K, L, L’ TV RF System PAL / SECAM Colour System NTSC 3.58 / 4.43 (Play back only)
Page 4
AV32L5EKGY AV32L5EIGY ■ ■ ■ ■ 21-pin Euro connector (SCART socket) : EXT-1 / EXT-2 / EXT-3 (P-P= Peak to Peak, S-W= Sync tip to white peak, B-W= Blanking to white peak) Signal Designation Matching Value EXT-1 EXT-2 EXT-3 ○...
AV32L5EKGY AV32L5EIGY SAFETY PRECAUTIONS 1. The design of this product contains special hardware and many have these special safety characteristics are identified in the circuits and components specially for safety purposes. For Parts List of Service Manual. Electrical components having such...
AV32L5EKGY AV32L5EIGY FEATURES " New chassis design enable use of an interactive on screen " Users can make VCR dubbing of picture and sound by controlling control. the AV selector to select an optional source at the EXT-2 output " The TELETEXT SYSTEM has a built-in FASTEXT (UK system), shown in figure bellow.
AV32L5EKGY AV32L5EIGY SPECIFIC SERVICE INSTRUCTIONS DISASSEMBLY PROCEDURE REMOVING THE REAR COVER CHECKING THE PW BOARD 1. Unplug the power cord. To check the back side of the PW Board. 1) Pull out the chassis. (Refer to REMOVING THE CHASSIS). 2. As shown in the Fig. 1, remove the 11 screws marked 2) Erect the chassis vertically so that you can easily check the 3.
Page 8
AV32L5EKGY AV32L5EIGY SPEAKER FRONT CABINET SPEAKER SOCKET FRONT CONTROL POWER & 100Hz DEF. PWB MICON CLAW CHASSIS AV TERMINAL BOARD CONTROL BASE CLAW MAIN PWB AV SW W W W Fig. 2 POWER CORD SIDE CONTROL JACK ASSEMBLY SPEAKER SPEAKER REAR COVER Fig.
Page 9
AV32L5EKGY AV32L5EIGY REMOVING THE CRT ! Replacement of the CRT should be performed by 2 or more persons. CRT CHANGE TABLE " After removing the cover, chassis etc., 1. Putting the CRT change table on soft cloth, the CRT change table should also be covered with such soft cloth (shown in Fig.4).
Page 10
AV32L5EKGY AV32L5EIGY REPLACEMENT OF MEMORY ICs 1. Memory ICs This TV use memory ICs. In the memory ICs, there are memorized data for correctly operating the video and deflection circuits. When replacing SERVICE MENU memory ICs, be sure to use ICs written with the initial values of data.
AV32L5EKGY AV32L5EIGY SERVICE ADJUSTMENTS BEFORE STARTING SERVICE ADJUSTMENT 1. There are 2 ways of adjusting this TV: One is with the 7. Preparation for adjustment (presetting): Unless otherwise specified in the adjustment items, preset the REMOTE CONTROL UNIT and the other is the conventional method using adjustment parts and components.
Page 14
AV32L5EKGY AV32L5EIGY ADJUSTMENT LOCATIONS SIDE CONTROL PWB HEAD PHONE FRONT CONTROL PWB S-IN FRONT CN102 F901 POWER SW MAIN PWB POWER&DEF PWB FRONT FRONT CN002 MICON PWB CN004 AV SW PWB CN007 CN005 TUNER CN006 CN003 CN013 CN014 100Hz PWB...
Page 15
AV32L5EKGY AV32L5EIGY BASIC OPERATION SERVICE MENU 1. TOOL OF SERVICE MENU OPERATION Operate the SERVICE MENU with the REMOTE CONTROL UNIT. 2. SERVICE MENU ITEMS With the SERVICE MENU, various settings (adjustments) can be made, and they are broadly classified in the following items of settings (adjustments): (1) 1.
Page 16
AV32L5EKGY AV32L5EIGY SERVICE MENU SERVICE MENU 1. IF 2. V/C 3. AUDIO 4. DEF 5. VSM PRESET 6. STATUS 8. --- 7. PIP 9. SHIPPING(ON) 0. BUS FREE 1-9 : SELECT : EXIT 1. V-SHIFT SUB MENU 4. DEF SUB MENU 1.IF 2.
Page 17
AV32L5EKGY AV32L5EIGY (3) Setting methods " Method of Setting 1.IF as [VCO] : It must not adjust without signal. ① 1 Key ・・・・・・・・・・・・・・・・・・・・・・・・・ Select 1.IF. ② 1 Key ・・・・・・・・・・・・・・・・・・・・・・・・ Select 1. VCO (CW) Check the arrow position from the “ABOVE REF.” to “BELOW REF.”...
Page 18
AV32L5EKGY AV32L5EIGY ADJUSTMENT CHECKING ITEM Measuring Item Test point Adjustment part Description instrument DC voltmeter Check of B1 TP-91(B1) 1. Receive any broadcast. TP-E(" " " " ) Power Supply 2. Press the ZOOM key and select the FULL mode.
Page 19
AV32L5EKGY AV32L5EIGY Measuring Item Test point Adjustment part Description instrument Adjustment of Signal SCREEN VR 1. Input the whole black signal. SCREEN VR generator (Within FBT) 2. Press the ZOOM key and select the FULL mode. 3. Select 2. V/C from the SERVICE MENU.
Page 20
AV32L5EKGY AV32L5EIGY VSM PRESET SETTING Measuring Item Test point Adjustment part Description instrument Setting of Remote 1. CONT. 1. Press the MENU key and select COOL mode with the remote VSM PRESET control unit 2. BRIGHT control unit. 2. Select 5.VSM PRESET from the SERVICE MENU.
Page 21
AV32L5EKGY AV32L5EIGY VIDEO/CHROMA CIRCUIT ADJUSTMENT The setting (adjustment) using the REMOTE CONTROL UNIT is made on the basis of the initial setting values. The setting values that adjust the screen to the optimum condition can be different from the initial setting values.
Page 22
AV32L5EKGY AV32L5EIGY Measuring Item Test point Adjustment part Description instrument Adjustment Remote 7.COLOUR [Method of adjustment without measuring instrument] of SUB control unit (PAL/SECAM/NTSC) COLOURⅠ Ⅰ Ⅰ Ⅰ PAL COLOUR 1. Receive PAL broadcast. 2. Select 2.V/C from the SERVICE MENU.
Page 23
AV32L5EKGY AV32L5EIGY Measuring Item Test point Adjustment part Description instrument Adjustment Signal TP-47B 7.COLOUR [Method of adjustment using measuring instrument] TP-E(" " " " ) of SUB generator (PAL/SECAM/NTSC) COLOUR Ⅱ Ⅱ Ⅱ Ⅱ [CRT Oscilloscope SOCKET PWB ] PAL COLOUR 1.
Page 24
AV32L5EKGY AV32L5EIGY Measuring Item Test point Adjustment part Description instrument Adjustment Remote 8.HUE [Method of adjustment without measuring instrument] control unit SUB HUEⅠ Ⅰ Ⅰ Ⅰ 1. Input a NTSC 3.58MHz COMPOSITE VIDEO signal (full field NTSC 3.58 HUE colour bar with 75% white) from the EXT terminal.
Page 25
AV32L5EKGY AV32L5EIGY Measuring Item Test point Adjustment part Description instrument 1. Input a PAL full field colour bar signal (75% white) from the EXT Adjustment Signal 10. VCO terminal. of VCO generator 2. Select 2. V/C from the SERVICE MENU.
Page 26
AV32L5EKGY AV32L5EIGY AUDIO CIRCUIT ADJUSTMENT [Do not adjust] Do not adjust 3. AUDIO of the SERVICE MENU as it requires no adjustment. If values had changed by the some reason set the initial values in the following table. Setting item...
Page 27
AV32L5EKGY AV32L5EIGY Measuring Item Test point Adjustment part Description instrument Adjustment Signal 1. V- SHIFT [FULL mode] of V-SHIFT generator 1. Receive a circle pattern signal of vertical frequency 50Hz. 2. Select 4.DEF from the SERVICE MENU. 3. Select 1.V-SHIFT with the FUNCTION UP/DOWN key.
Page 28
AV32L5EKGY AV32L5EIGY Measuring Item Test point Adjustment part Description instrument 13. Receive a circle pattern signal. Adjustment of Signal 3.H-CENT. generator 14. Select 3.H-CENT and set the initial setting value. H. CENTER Remote 15. Adjust H-CENT to make C=D .
Page 29
AV32L5EKGY AV32L5EIGY Measuring Item Test point Adjustment part Description instrument 25. Receive a cross-hatch signal. Adjustment Signal 5.TRAPEZ of TRAPEZ generator 26. Select 5.TRAPEZ with the FUNCTION UP/DOWN key. 27. Set the initial setting value of TRAPEZ with the FUNCTION - Remote or + key.
Page 30
AV32L5EKGY AV32L5EIGY Measuring Item Test point Adjustment part Description instrument " In case where there is a bow-shaped distortion of images on the Adjustment Signal 11.BOW of BOW generator screen. 41. Select 11.BOW with the FUNCTION UP/DOWN key. 42. Adjust BOW, and bring the VERTICAL lines straight.
Page 31
AV32L5EKGY AV32L5EIGY REPLACEMENT OF CHIP COMPONENT ! CAUTIONS 1. Avoid heating for more than 3 seconds. 2. Do not rub the electrodes and the resist parts of the pattern. 3. When removing a chip part, melt the solder adequately. 4. Do not reuse a chip part after removing it.
Page 32
VICTOR COMPANY OF JAPAN, LIMITED HOME AV NETWORK BUSINESS UNIT 12, 3-chome, Moriya-cho, Knagawa-ku, Yokohama, Kanagawa-prefecture, 221-8528, Japan AV32L5EKGY-U #3 Printed in Japan AV32L5EIGY-U #3 VP 0106 DP3051...
AV32L5EKGY AV32L5EIGY PARTS LIST CAUTION ! The parts identified by the symbol are important for the safety. Whenever replacing these parts, be sure to use specified ones to secure the safety . ! The parts not indicated in this Parts List and those which are filled with lines in the Parts No. columns will not be supplied.
Page 34
AV32L5EKGY AV32L5EIGY CONTENTS ! ! ! ! USING PW BOARD & REMOTE CONTROL UNIT ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ ! ! ! ! EXPLODED VIEW PARTS LIST ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 33, 34 ! ! ! ! EXPLODED VIEW ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 33, 35 ! ! ! ! PRINTED WIRING BOARD PARTS LIST AV32L5EKGY "...
Page 37
AV32L5EKGY AV32L5EIGY EXPLODED VIEW (2) ( × 4) POWER & DEF. SOCKET FRONT MICON 100Hz CONTROL T2551 SIDE CONTROL MAIN PWB ( × 3) AV SW ( × 11) No.51779...
AV32L5EKGR AV32L5EKGR AV32L5EKBL AV32L5EKBL AV32L5EIGR AV32L5EIGR AV32L5EIBL AV32L5EIBL STANDARD CIRCUIT DIAGRAM AV SW PWB PATTERN n NOTE ON USING CIRCUIT DIAGRAMS Type 1. SAFETY No indication :Ceramic capacitor The components identified by the symbol and shading are :Mylar capacitor :Metalized mylar capacitor critical for safety.
Page 69
AV32L5EKGR AV32L5EKGR AV32L5EKBL AV32L5EKBL AV32L5EIGR AV32L5EIGR AV32L5EIBL AV32L5EIBL FRONT CONTROL PWB PATTERN SIDE CONTROL PWB PATTERN FRONT No.51779 2-29 2-30 No.51779...