ABB Protronic 100 Manual page 38

Profibus-dp interface and module
Table of Contents

Advertisement

Decimal
Read
hexadecimal
1923
0x0783
1051
0x041B
569
0x0239
1919
0x077F
587
0x024B
511
0x01FF
589
0x024D
495
0x01EF
503
0x01F7
509
0x01FD
505
0x01F9
541
0x021D
1913
0x0779
543
0x021F
557
0x022D
1912
0x0778
863
0x035F
473
0x01D9
553
0x0229
529
0x0211
475
0x01DB
567
0x0237
1922
0x0782
531
0x0213
533
0x0215
535
0x0217
537
0x0219
861
0x035D
467
0x01D3
551
0x0227
865
0x0361
869
0x0365
487
0x01E7
489
0x01E9
507
0x01FB
555
0x022B
497
0x01F1
491
0x01EB
561
0x0231
565
0x0235
493
0x01ED
559
0x022F
563
0x0233
selection
519
0x0207
463
0x01CF
1797
0x0705
798
0x031E
38 Loop 3
Write
Variable
hexadecimal
name
0xF87D
.L3_SETZ_MAN
0xFBE5
.L3_SETZ_W
0xFDC7
.L3_SKALV
0xF881
.L3_SPAKTIV
0xFDB5
.L3_T1
0xFE01
.L3_T1_STEUER
0xFDB3
.L3_T2
0xFE11
.L3_TIME_DPS_MAN
0xFE09
.L3_TN_STEUER
0xFE03
.L3_TT_STEUER
0xFE07
.L3_TV_STEUER
0xFDE3
.L3_V
0xF887
.L3_V_F
0xFDE1
.L3_VISTDIGI
0xFDD3
.L3_W_FOLGE
0xF888
.L3_W_STATUS
0xFCA1
.L3_WAKT
0xFE27
.L3_WANA
0xFDD7
.L3_WANA_SKAL
0xFDEF
.L3_WCOMPUTER
0xFE25
.L3_WDIGI
0xFDC9
.L3_WEXT
0xF87E
.L3_WEXT_AKTIV
0xFDED
.L3_WSOLL0
0xFDEB
.L3_WSOLL1
0xFDE9
.L3_WSOLL2
0xFDE7
.L3_WSOLL3
0xFCA3
.L3_WW
0xFE2D
.L3_XANA
0xFDD9
.L3_XANA_SKAL
0xFC9F
.L3_XDIGI
0xFC9B
.L3_XW
0xFE19
.L3_XW_EU
0xFE17
.L3_XW_PRZ
0xFE05
.L3_Y0_STEUER
0xFDD5
.L3_YCOMPUTER
0xFE0F
.L3_YHAND
0xFE15
.L3_YMAX
0xFDCF
.L3_YMAX_BR
0xFDCB
.L3_YMAX_HR
0xFE13
.L3_YMIN
0xFDD1
.L3_YMIN_BR
0xFDCD
.L3_YMIN_HR
0xFDF9
.L3_YSRUECK
0xFE31
.L3_YTRACK
0xF8FB
.SLH_LOOP3
0xFCE2
.WW_LOOP3
Data type Comment
BOOL
Change-over to man. mode
INT
Change-over to setpoint source
REAL
Scaling factor ratio with LOAD AIR
BOOL
Auto-configuration active
DINT
Free time variable
REAL
Effective delay time T1
DINT
Free time variable
DINT
Step output increment [ms]
REAL
Effective integral action time [min]
REAL
Effective dead time Tt [min]
REAL
Effective derivative action time [min]
REAL
Setpoint ratio
BOOL
Fixed value/ratio status
REAL
Actual ratio
REAL
Setpoint for slave control in cascade
BOOL
REAL
Current setpoint
REAL
REAL
SP bargraph
REAL
Computer target setpoint %
REAL
Current setpoint
REAL
External setpoint
BOOL
External SP active
REAL
Target setpoint 1
REAL
Target setpoint 2
REAL
Target setpoint 3
REAL
Target setpoint 4
REAL
Effective setpoint
REAL
REAL
PV bargraph
REAL
Digital display PV
REAL
Control deviation in engineering units
REAL
Control deviation in engineering units
REAL
Control deviation in %
REAL
Effective operating point [%]
REAL
OUT COMPUTER with DDC
REAL
Man. value of output variable
REAL
Max. output value
REAL
Override selection for override controller
REAL
Override selection for master controller, MIN. selection
REAL
Min. output value
REAL
OUT-Min override selection for override controller
REAL
Override selection for master controller, MAX.
REAL
Position feedback
REAL
OUT tracking signal in AUTO mode
BOOL
Loop 3 in display
INT
Index of selected setpoint loop 3