ABB Protronic 100 Manual page 36

Profibus-dp interface and module
Table of Contents

Advertisement

Decimal
Read
hexadecimal
1883
0x075B
1050
0x041A
419
0x01A3
1879
0x0757
437
0x01B5
361
0x0169
439
0x01B7
345
0x0159
353
0x0161
359
0x0167
355
0x0163
391
0x0187
1873
0x0751
393
0x0189
407
0x0197
1872
0x0750
843
0x034B
323
0x0143
403
0x0193
379
0x017B
325
0x0145
417
0x01A1
1882
0x075A
381
0x017D
383
0x017F
385
0x0181
387
0x0183
841
0x0349
317
0x013D
401
0x0191
845
0x034D
849
0x0351
337
0x0151
339
0x0153
357
0x0165
405
0x0195
347
0x015B
341
0x0155
411
0x019B
415
0x019F
343
0x0157
409
0x0199
413
0x019D
selection
369
0x0171
313
0x0139
1796
0x0704
797
0x031D
36 Loop 2
Write
Variable
hexadecimal
name
0xF8A5
.L2_SETZ_MAN
0xFBE6
.L2_SETZ_W
0xFE5D
.L2_SKALV
0xF8A9
.L2_SPAKTIV
0xFE4B
.L2_T1
0xFE97
.L2_T1_STEUER
0xFE49
.L2_T2
0xFEA7
.L2_TIME_DPS_MAN
0xFE9F
.L2_TN_STEUER
0xFE99
.L2_TT_STEUER
0xFE9D
.L2_TV_STEUER
0xFE79
.L2_V
0xF8AF
.L2_V_F
0xFE77
.L2_VISTDIGI
0xFE69
.L2_W_FOLGE
0xF8B0
.L2_W_STATUS
0xFCB5
.L2_WAKT
0xFEBD
.L2_WANA
0xFE6D
.L2_WANA_SKAL
0xFE85
.L2_WCOMPUTER
0xFEBB
.L2_WDIGI
0xFE5F
.L2_WEXT
0xF8A6
.L2_WEXT_AKTIV
0xFE83
.L2_WSOLL0
0xFE81
.L2_WSOLL1
0xFE7F
.L2_WSOLL2
0xFE7D
.L2_WSOLL3
0xFCB7
.L2_WW
0xFEC3
.L2_XANA
0xFE6F
.L2_XANA_SKAL
0xFCB3
.L2_XDIGI
0xFCAF
.L2_XW
0xFEAF
.L2_XW_EU
0xFEAD
.L2_XW_PRZ
0xFE9B
.L2_Y0_STEUER
0xFE6B
.L2_YCOMPUTER
0xFEA5
.L2_YHAND
0xFEAB
.L2_YMAX
0xFE65
.L2_YMAX_BR
0xFE61
.L2_YMAX_HR
0xFEA9
.L2_YMIN
0xFE67
.L2_YMIN_BR
0xFE63
.L2_YMIN_HR
0xFE8F
.L2_YSRUECK
0xFEC7
.L2_YTRACK
0xF8FC
.SLH_LOOP2
0xFCE3
.WW_LOOP2
Data type Comment
BOOL
Change-over to man. mode
INT
Change-over to setpoint source
REAL
Scaling factor ratio with LOAD AIR
BOOL
Auto-configuration active
DINT
Free time variable
REAL
Effective delay time T1
DINT
Free time variable
DINT
Step output increment [ms]
REAL
Effective integral action time [min]
REAL
Effective dead time Tt [min]
REAL
Effective derivative action time [min]
REAL
Setpoint ratio
BOOL
Fixed value/ratio status
REAL
Actual ratio
REAL
Setpoint for slave control in cascade
BOOL
REAL
Current setpoint
REAL
REAL
SP bargraph
REAL
Computer target setpoint
REAL
Current setpoint
REAL
External setpoint
BOOL
External SP active
REAL
Target setpoint 1
REAL
Target setpoint 2
REAL
Target setpoint 3
REAL
Target setpoint 4
REAL
Effective setpoint
REAL
REAL
PV bargraph
REAL
Digital display PV
REAL
Control deviation in engineering units
REAL
Control deviation in engineering units
REAL
Control deviation in %
REAL
Effective operating point [%]
REAL
OUT COMPUTER with DDC
REAL
Man. value of output variable
REAL
Max. output value
REAL
Override selection for override controller
REAL
Override selection for master controller, MIN. selection
REAL
Min. output value
REAL
OUT-Min override selection for override controller
REAL
Override selection for master controller, MAX.
REAL
Position feedback
REAL
OUT tracking signal in AUTO mode
BOOL
Loop 2 in display
INT
Index of selected setpoint loop 2