2 CONNECTING OPTIONAL DEVICES
8. Dress the KAP-2 cable (E37-1160-x5) into the
transceiver as shown in the figure.
9. Insert the 6-pin connector of the connection cable
into the Relay PCB connector (CN2).
50
CONTENTS
10. Remove the cable with the connector that is
inserted into the connector (CN6) of the TX-RX
PCB
11. Plug the cable with the connector (E37-1159-x5)
into the connector (CN3) on the Relay PCB, then
plug the other end into the connector (CN6) on the
TX-RX PCB.
12. Peal off the coated paper of G13-2063-x4 and
attach the cable to the KAP-2 Relay PCB.
13. Put the DC cable back into place and install the
shielding plate, upper packing, and the upper
case on the transceiver.
Confidential
MOD (K)/Ver. 2.00