Kgp-2A/ Kgp-2B - Kenwood TK-7160 Modification Information

Hide thumbs Also See for TK-7160:
Table of Contents

Advertisement

2 CONNECTING OPTIONAL DEVICES

2.5 KGP-2A/ KGP-2B

A data terminal (KGP-2A/ KGP-2B) used for
establishing data communications can be connected
to the TK-7160/ TK-8160. This section describes how
to connect KGP-2A/ KGP-2B to the TK-7160/
TK-8160.
2.5.1 Installing KGP-2A/ KGP-2B
1. Connect the KCT-39 cable to the transceiver.
Refer to
2.1.4 Installing KCT-39 on page 12
connecting the cable.
2. Connect the KCT-39 cable to KGP-2A/ KGP-2B.
If KCT-39 and KGP-2A/ KGP-2B are too far apart,
the KCT-36 extension cable must be used to
connect them.
2.5.2 Configuration using KPG-99D
1. Run KPG-99D.
2. Select the Program pulldown menu > "Read Data
from the Transceiver". The icon in the toolbar can
also be clicked.
20
CONTENTS
The Read Data from the Transceiver dialog box
appears on the display.
Figure 2-10 Read Data from the Transceiver Dialog Box 1
3. Click the "Read" button.
KPG-99D starts reading configuration data from the
while
transceiver.
Figure 2-11 Read Data from the Transceiver Dialog Box 2
4. Click the Edit pulldown menu > "Function Port".
The Function Port window appears on the display.
KCT-36
5. Select the External Device (Port 3 to 8) dropdown
list > "KGP-2A/ KGP-2B".
The necessary functions to use KGP-2A/ KGP-2B
are automatically assigned to each port.
Note: In this case, Ignition Function cannot be configured.
Confidential
Figure 2-12 Function Port Window
MOD (K)/Ver. 2.00