Communication Test - HomeMatic HmIP-SWSD Mounting Instruction And Operating Manual

Smoke alarm with q label
Table of Contents

Advertisement

Available languages

Available languages

time briefly.
If the alarm sound is triggered 3 times, the LED
flashes red and the escape light flashes during
the function test, the smoke alarm is working
correctly.
If no alarm sound is triggered or no visual signal
can be detected, the device is defective and has
to be replaced.
After the functional test, the smoke detection is
deactivated for 10 minutes. During this time, no
alarm can be triggered.
6.2

Communication test

The correct integration of the smoke alarm into the wire-
less network and the error-free communication to other
smoke alarms can be tested by sending a radio signal to
the smoke alarm. To send a radio test signal, proceed as
follows:
Press and hold down the operating button (D) for
longer than 4 seconds. The communication test
starts and a radio test signal is send. The status
LED lights up orange.
All smoke alarms that are part of the radio net-
work will react to the radio signal.
If transmission has been successful, the LEDs of
smoke alarms that have received the signal will
Operation