@RF GAIN CONTROL
RF GAIN is controlled by changing the AGC threshold vol-
tage. Adjust the RF GAIN so the S-meter reading in-
creases to a point just lower than speech peaks. This also
reduces noise during reception. For normal operation, this
control should be turned fully clockwise for maximum sen-
sitivity.
• @
AGC switch
The AGC control is normally set as follows:
FAST............. CW, FSK
SLOW ........... SSB
OFF ............... Weak signal reception
The S-meter does not function in the OFF position.
Simultaneous use of the RF GAIN control and AGC switch
may be of assistance when strong local signals are pre-
sent. If a strong signal (such as a local amateur radio sta-
tion) appears near the desired receive signal, the S-meter
may show unusual deflection due to the AGC voltage that
is developed as a result of the strong meter being signal. If
this occurs, tum the RF GAIN down so the meter pointer
remains at approximately the original deflection peak, and
tum the AGC switch OFF.
This will eliminate the unwanted AGC voltage and permit
clear reception.