Maintenance - Delabie TEMPOSOFT Installation Instructions Manual

Soft-touch, time flow mixer/tap and valve
Table of Contents

Advertisement

MAINTENANCE

Foreign bodies in the pipework can cause the mechanism to malfunction. To remove the
mechanism (fig. I):
• Remove the grub screw  using a 2.5mm Allen key.
• Remove the push-button .
• Unscrew the cartridge
using a 28mm spanner.
Automatic shut-off takes too long or there is continuous flow (fig. K)
• Clean the inside of the delay case
using a clean, dry cloth; and clean the calibrated groove
with a non-metallic, sharp point.
• Check that the lip seal
and seat
are in good condition.
• Remember to replace the spring .
Dripping or a constant trickle (fig. K)
• Clean the seat
or replace if damaged.
• Remember to replace the spring .
Beware: do not grease the inside of the mechanism.