Four-Faith F2003 Series User Manual

Four-Faith F2003 Series User Manual

Gsm ip modem

Advertisement

Quick Links

F2003 Series
User Manual
F2003 Series User Manual
The user manual is suitable for the following model:
Documentation No.
Product Name:
Model
Product Type
F2003
GSM IP MODEM
Xiamen Four-Faith Communication Technology Co., Ltd.
Add:J1-J3,3rd Floor,No.44,GuanRi Road,SoftWare
Park,XiaMen,China
Tel:+86 592-6300326 ,6300325,6300324
Fax:+86 592-5912735
http://www.fourfaith.com
Product Version
Zip Code:361008
Page
Total:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the F2003 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Four-Faith F2003 Series

  • Page 1 Product Name: Total: F2003 Series User Manual The user manual is suitable for the following model: Model Product Type F2003 GSM IP MODEM Xiamen Four-Faith Communication Technology Co., Ltd. Add:J1-J3,3rd Floor,No.44,GuanRi Road,SoftWare Park,XiaMen,China Zip Code:361008 Tel:+86 592-6300326 ,6300325,6300324 Fax:+86 592-5912735 http://www.fourfaith.com...
  • Page 2 User Manual Files Revised Record Date Version Remark Author Xiamen Four-Faith Communication Technology Co.,Ltd. Page 2 of 22 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel: +86 592-6300326 6300325 6300324 Fax:+86 592-5912735...
  • Page 3 Four-Faith Communication Technology Co., Ltd. Without written permission, all commercial use of the files from Four-Faith are forbidden, such as copy, distribute, reproduce the files, etc., but non-commercial purpose, downloaded or printed by individual (all files shall be not revised, and the copyright and other proprietorship notice shall be reserved) are welcome.
  • Page 4 User Manual Xiamen Four-Faith Communication Technology Co.,Ltd. Page 4 of 22 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel: +86 592-6300326 6300325 6300324 Fax:+86 592-5912735...
  • Page 5: Table Of Contents

    3.3.5 SMS Center ......................18 3.3.6 Debug Level ......................18 3.3.7 Retry Times ......................19 3.3.8 Bytes Interval ......................19 Appendix ............................20 Xiamen Four-Faith Communication Technology Co.,Ltd. Page 5 of 22 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel: +86 592-6300326 6300325 6300324...
  • Page 6: Chapter 1 Brief Introduction Of Product

     RS232/RS485/RS422 port: 15KV ESD protection  SIM/UIM port: 15KV ESD protection  Power port: reverse-voltage and overvoltage protection  Antenna port: lightning protection(optional) Xiamen Four-Faith Communication Technology Co.,Ltd. Page 6 of 22 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel:...
  • Page 7: Working Principle

    Compliant to GSM phase 2/2+ Bandwidth 14.4Kbps CSD TX power GSM850/900: <33dBm GSM1800/1900: <30dBm RX sensitivity <-107dBm Hardware System Item Content Xiamen Four-Faith Communication Technology Co.,Ltd. Page 7 of 22 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel: +86 592-6300326 6300325 6300324 Fax:+86 592-5912735...
  • Page 8 Dimensions 91x58.5x22 mm Weight 205g Environmental Limits Item Content Operating -25~+65º C(-13~+149℉) Temperature Extended -30~+75º C(-22~+167℉) Operating Temperature Xiamen Four-Faith Communication Technology Co.,Ltd. Page 8 of 22 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel: +86 592-6300326 6300325 6300324 Fax:+86 592-5912735...
  • Page 9 User Manual Storage -40~+85º C(-40~+185℉) Temperature Operating 95% ( Non-condensing) Humidity Xiamen Four-Faith Communication Technology Co.,Ltd. Page 9 of 22 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel: +86 592-6300326 6300325 6300324 Fax:+86 592-5912735...
  • Page 10: Chapter 2 Installation Introduction

    RS485 data cable optional Manual CD Certification card Maintenance card 2.3 Installation and Cable Connection : (unit: mm) Dimension Xiamen Four-Faith Communication Technology Co.,Ltd. Page 10 of 22 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel: +86 592-6300326 6300325 6300324 Fax:+86 592-5912735...
  • Page 11 Insert DB9F end of the RS232/RS485 data cable into the DB9M interface of IP MODEM, and connect the other end with user’s device. The signal connection of the RS232 data cable is as follows: Xiamen Four-Faith Communication Technology Co.,Ltd. Page 11 of 22 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China...
  • Page 12: Power

    Warning: When we use other power, we should make sure that the power can supply power above 4W. We recommend user to use the standard DC 12V/0.5A power adaptor. Xiamen Four-Faith Communication Technology Co.,Ltd. Page 12 of 22 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China...
  • Page 13: Indicator Lights Introduction

    BLINK Data is communicating No data Online IP MODEM has logged on network IP MODEM hasn’t logged on network Xiamen Four-Faith Communication Technology Co.,Ltd. Page 13 of 22 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel: +86 592-6300326 6300325 6300324 Fax:+86 592-5912735...
  • Page 14: Chapter 3 Configuration

    3.2 Enter Configure State Run FfSmsIP MODEMConfig-En.exe configure tool, as following: Click “Open” button, State column displays the following information, Software is waiting IP MODEM enter configure state. Xiamen Four-Faith Communication Technology Co.,Ltd. Page 14 of 22 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com...
  • Page 15: Configuration

    IP MODEM has been in configure state, It’s ready for configuring its parameters. 3.3 Configuration 3.3.1 Serial Port Parameters Baud rate The serial port communication speed AT Command: AT+IPR=xxxx Xiamen Four-Faith Communication Technology Co.,Ltd. Page 15 of 22 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel: +86 592-6300326 6300325 6300324 Fax:+86 592-5912735...
  • Page 16: Workmode

    : Peer phone number length phone: Peer phone number data_len_high:SMS content length high byte data_len_low:SMS content length low byte Xiamen Four-Faith Communication Technology Co.,Ltd. Page 16 of 22 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel: +86 592-6300326 6300325 6300324...
  • Page 17: Hex Sms

    In this mode, IP MODEM can send any characters(0x00 ~ 0xff) to peer phone, So, it can be used in industrial monitor applications. AT Command: AT+HEXSMS=x x: 0 or 1 ,0 normal SMS,1 HEX SMS Xiamen Four-Faith Communication Technology Co.,Ltd. Page 17 of 22 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel:...
  • Page 18: Peer Phone

    0 :No debug information output 1 :Simple prompt information 2 : Detail debug information AT Command: AT+DEBUG=x x: the debug value Xiamen Four-Faith Communication Technology Co.,Ltd. Page 18 of 22 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel: +86 592-6300326 6300325 6300324...
  • Page 19: Retry Times

    IP MODEM will send the serial data to peer phone when two bytes transmit time interval larger than this item value. AT Command: AT+BYTEINT=xxx xxx: bytes interval value Xiamen Four-Faith Communication Technology Co.,Ltd. Page 19 of 22 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel:...
  • Page 20: Appendix

    2. Input connection name, choose “OK” 3. Choose the correct COM port which connect to IP MODEM, choose “OK” 4. Configure the serial port parameters as following, choose “OK” Xiamen Four-Faith Communication Technology Co.,Ltd. Page 20 of 22 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China...
  • Page 21 Flow control: None 5. Complete Hyper Terminal operation, It runs as following Re-power IP MODEM, put mouse focus on the Hyper Terminal and press “s” key Xiamen Four-Faith Communication Technology Co.,Ltd. Page 21 of 22 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com...
  • Page 22 User Manual continuously until IP MODEM enter configure state as following 7. IP MODEM has entered configure state, you can configure the parameters through AT command. Xiamen Four-Faith Communication Technology Co.,Ltd. Page 22 of 22 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com...

Table of Contents