IRD
FISIOLASER
FISIOLASER IRD 2
USER'S MANUAL
0476
FISIOLASER IRD EL12061 – A01
Rev.02 - 07/2018
mod.14-2013.07.15-17.30-A01-gb.docx
FISIOLASER IRD2 EL12062 – A01

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FISIOLASER IRD and is the answer not in the manual?

Questions and answers

Summary of Contents for chinesport FISIOLASER IRD

  • Page 1 FISIOLASER FISIOLASER IRD 2 USER’S MANUAL 0476 FISIOLASER IRD EL12061 – A01 Rev.02 - 07/2018 mod.14-2013.07.15-17.30-A01-gb.docx FISIOLASER IRD2 EL12062 – A01...
  • Page 2: Table Of Contents

    Appendix C List of programs ..............39 DESCRIPTION OF THE EQUIPMENT ........14 Appendix D Electro-magnetic compatibility tables ......... 41 CONTROL PANEL ................. 14 FRONT PANEL ..................14 BACK PANEL ..................15 INDICATIONS ................15 CONTRA - INDICATIONS ............15 2 / 39 FISIOLASER IRD/IRD 2...
  • Page 3: Introduction

    The refraction index of many transparent materials in the visible spectrum is between The beam is practically always parallel and laser radiation can propagate for very 1.4 and 1.8. It is higher in the infrared (IR) spectrum and is between 2.0 and 4.0 . long distances. 3 / 39 FISIOLASER IRD/IRD 2...
  • Page 4: Components Of Laser Systems

    The pn junction refers to a “p” type semiconductor attached to an “n” type. Special types of laser diodes have been developed to get high power laser diodes. This junction conducts electricity in a preferred direction. 4 / 39 FISIOLASER IRD/IRD 2...
  • Page 5: Beam Diameter

    CW – Pulsed Type of emission = 20 W x 200.10 sec. x 5 x 10 Guide light He-Ne (red) or green ANSI safety standard 3B and 4 = 0,02 Watt = 20 mWatt 5 / 39 FISIOLASER IRD/IRD 2...
  • Page 6 J/cm By A. Vasta: therapeutic lasers….Marrapese Pub. . Rome,1998. Since 1 J = 1 W*sec, the amount of radiation D can be calculated in the following manner : 6 / 39 FISIOLASER IRD/IRD 2...
  • Page 7 The optimal weekly radiation amount for He-Ne laser therapy seems to be about 1 The average power of a single pulse laser depends on its frequency (F), and the J/cm energy/pulse ratio (E/i), as shown in the following table of a GaAs laser with different frequencies : 7 / 39 FISIOLASER IRD/IRD 2...
  • Page 8: Information On The Manual

    DDT / invoice. His identification saves time highlight their importance. and improves the quality of the intervention.  The equipment in need of repair in the Chinesport must expose on the shipping Notes packing the "AUTHORIZATION NUMBER" to require toTechnical Assistance, its identification saves time and improves the quality of the service.
  • Page 9: In General

    UNPACKING When re-packing the equipment for return to the manufacturer, proceed as follows: FISIOLASER IRD-series equipment is specially packaged for transport in a single Unplug the machine and any connections, devices, applicators etc; pack complete with filling which has been specifically studied for safe transportation and storage.
  • Page 10 The following environmental conditions are ideal when installing the FISIOLASER IRD-series unit : - room temperature from +10° to +40°C - humidity level from 10% to 80% without condensation - avoid direct exposure to sunlight, chemical products and vibrations Fig. D 10 / 39 FISIOLASER IRD/IRD 2...
  • Page 11: Electrical Connection

    Make sure that power supply socket has been earthed. CAUTION The equipment must only be connected Do not use FISIOLASER IRD-series equipment to power supply units that comply wherever there is a risk of either the external with all safety directives in force.
  • Page 12: Lighting Of The Device

    It is recommended not to start the emission of treatment if the device isn’t in perfect mechanical conditions . When the Unit is switched on, the LCD display lights up and FISIOLASER IRD- series unit is ready for use .
  • Page 13: Accessories

    MLA5/125 Laser probe 905nm guide light+ 5 diode 25 IRD-series device is guaranteed in the respect mW (125mW total) MLA5/500 Laser probe 905nm guide light+ 5 diode 100 of the standards of installation and use pointed out, mW (500mW total) 13 / 39 FISIOLASER IRD/IRD 2...
  • Page 14: Description Of The Equipment

    1) LCD graphic display parts of exchange. 2) Left side function buttons If there are problems or installation difficulties, please contact the CHINESPORT 3) Right side function buttons SpA technical assistance department. 4) START button...
  • Page 15: Back Panel

    4. Thyroid: laser must never be used over the thyroid. 3. Bruises: are treated with laser those with sequelae, the most serious or that you 5. Haemorrhages: indirect laser vaso-dilatation may worsen the haemorrhaging. want to solve as soon as possible. 15 / 39 FISIOLASER IRD/IRD 2...
  • Page 16: How To Use The Equipment

    This section provides important information and instructions on how to make the best use of the FISIOLASER IRD-series equipment for laser therapy. (led diodes), what they have a driving function , All the control functions and the machine itself are handled and co-ordinated by a in conformity to the EN 60601-2-22 standard .
  • Page 17: Designated Use

    Do not use your FISIOLASER IRD-series unit in the presence of flammable materials DESIGNATED USE ( for example , paper ) ; in the event of default , CHINESPORT SpA shall not be The FISIOLASER IRD-series unit is a electro-medical device that delivers laser- consider...
  • Page 18: Set Up

    It is advisable to suspend the therapeutic Once turned on, the LCD display lights up and FISIOLASER IRD-series unit is treatment if it were to appear some ready for use (see .2 ).
  • Page 19: Display

    Otherwise , press the CANCEL button for to return to the screen of fig. 9 . fore-colour and the back-colour . For to adjust the contrast settings , please follow these instructions : 1. press the function taste relative to the SETTINGS button in the main menu 19 / 39 FISIOLASER IRD/IRD 2...
  • Page 20: Probe

    Press the START button : as default , the device runs the emission with the modality saved in the last session . It’s possible to select the next modalities for the emission of the treatment :  “Manual” emission modality  “Automatic” emission modality 20 / 39 FISIOLASER IRD/IRD 2...
  • Page 21 , and will restart by the interruption point when the contact contact between the laser probe and the patient to treat ; the treatment sensor has been pressed again restart by the interruption point when the contact will be restored 21 / 39 FISIOLASER IRD/IRD 2...
  • Page 22 , otherwise press the function taste relative to the SAVE button ( see N.B. Output channel 1 is the only one available in the FISIOLASER IRD . fig. 16 ) : you return to the screen of fig. 9 8) Press the function taste relative to the EXIT button ( see fig.
  • Page 23: Various

    You can also use the “Format Smart-card” function to delete it completely. If you do this it can be used on a different unit. In order to avoid accidental deletion, you are asked to confirm the operation 23 / 39 FISIOLASER IRD/IRD 2...
  • Page 24: Language

    (see fig. 20) : Fig. 25 N.B. Output channel 1 is the only one available in the FISIOLASER IRD . Press the channel button to select the output channel . The term Channel <1> that appears on the top left indicates that the displayed programme will be operated from Channel 1.
  • Page 25: Loading Programmes

     Appendix C shows a list of the programmes available . Push the START button for to run its emission , or NOTE: Output channel 1 is the only one available in FISIOLASER IRD 25 / 39 FISIOLASER IRD/IRD 2...
  • Page 26: Application Of The Therapy

    START button . in the presence of flammable materials APPLICATION OF THE THERAPY ( for example , paper ) ; in the event of default , CHINESPORT SpA shall not be consider ! WARNING !
  • Page 27 STOP button again, the emission will be stopped completely. Channel 2 As previously noted, the FISIOLASER IRD-series unit is an IR diode laser beam designed and manufactured in full accordance with national and international safety Fig. 23 standards (see Appendix) .
  • Page 28: Laser Test

    ! WARNING ! 4) Rotate the encoder knob until to position the cursor on the parameter that To avoid contamination of the use environment for FISIOLASER IRD-series unit you wants to modify and / or persons involved in its use, do not apply to contact with patients laser...
  • Page 29: Maintenance

    . MAINTENANCE The FISIOLASER IRD-series device for laser therapy does not require any particular maintenance operations , but only a periodic maintenance and cleanliness of the laser probes, in order to ensure the better operating conditions, guarantee the effectiveness of the treatment and the safety of the patient .
  • Page 30 The laser probes, particularly the head of treatment, periodically should be cleaned Do not spray or pour liquid onto the external parts of the FISIOLASER IRD-series with water and denatured alcohol . equipment and onto the laser-probes .
  • Page 31: Technical Problems

    (lilt at least 2 years), In order to make a correct substitution of the fuses housed in FISIOLASER IRD- series unit , please follow these instructions :...
  • Page 32: Electromagnetic Interference

    . The customer, upon prior request, may view the reports relative to EMC measures within the company . The FISIOLASER IRD-series unit for laser-therapy equipment does not generate significant radio frequency energy and is adequately immune to radiated electromagnetic fields.
  • Page 33: Troubleshooting Chart

    Faulty components on LCD display on Plug incorrectly inserted Check that the socket is electronic control circuit. front panel does not Contact CHINESPORT into socket. working correctly. light up. SpA Service centre . Faulty supply on laser circuit. Power cable incorrectly...
  • Page 34: Technical Specifications

    TECHNICAL SPECIFICATIONS 5 frequencies per Automatic scanning decade FISIOLASER IRD / FISIOLASER IRD 2 Solid-state Laser , Pointer 3mW @ 650nm 230 Vac, 50-60Hz, (10 – 100 ) % Pulsed mode ±10% Mains voltage: 25 W 115 Vac, 50-60Hz, Peak power for single diode ±10% *...
  • Page 35 MLA3 (75) – pulsed laser diode FISIOLASER IRD 2 4.30 Kg Number of laser diodes Unit body weight FISIOLASER IRD 4.30 Kg Wavelength 905nm Divergence of the beam 192x436mrad Room temperature (+10 ÷ +40) °C Duration of the impulse 100ns 100 –...
  • Page 36: Appendices

    Appendix A ENVIRONMENTAL CONSIDERATIONS DNRO (Nominal eye-hazard distance) direct light 251 mm FISIOLASER IRD-series unit for laser therapy equipment has been designed and MLA8 (200) – pulsed laser diode manufactured to have minimal negative environmental impact, in line with its Number of laser diodes operational and safety requirements.
  • Page 37: Appendix B Labels

    Table 2 Appendix B LABELS Here are the table containing the symbols on the label plate and their meanings. Table 1 SYMBOL SIGNIFICATION This product complies with regulations issued under the certification from a 0476 Notified Body Applied part BF “Caution Laser Beam”...
  • Page 38 Label applied near the output channel 1 of the Label applied near the output channel 2 of the device device ( only for FISIOLASER IRD 2 ) Label applied on the laser probe, showing Label indicating "LASER APERTURE", the Manufacturer's name or trade mark and placed near the firing part of the laser probe.
  • Page 39: Appendix C List Of Programs

    Appendix C List of programs 31 Herpes Simplex 0.02 32 Lombalgia 4.50 10000 Suggested 33 Sciatalgia 3.00 10000 Duration Frequency Laser Therapy Treatments sessions 34 Burns 1 0.03 1000 (J/cm ( min. ) ( Hz ) ( N° ) 35 Burns 2 0.30 5000 1 Acne...
  • Page 40 62 Adductor Tendinopathty 1 0.75 5000 63 Adductor Tendinopathty 2 0.12 2000 Biceps Brachii 6.00 10000 Tendinopathy 1 Biceps Brachii 1.05 5000 Tendinopathy 2 Biceps Femoris 0.75 5000 Tendinopathy Gluteus Medius 4.50 10000 minimus Tendinopathy Long short lateral 3.00 10000 peroneal Tendinopathy 1 Long short...
  • Page 41: Appendix D Electro-Magnetic Compatibility Tables

    The customer or the user of the FISIOLASER IRD-series ME EQUIPMENT should assure that environment specified below. it is used in such an environment. The customer or the user of the FISIOLASER IRD-series ME EQUIPMENT should assure that it Electromagnetic environment – IEC 60601 Compliance is used in such an environment.
  • Page 42 IEC 61000-4-6 150kHz to 80MHz The customer or the user of the FISIOLASER IRD-series ME EQUIPMENT can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the FISIOLASER IRD-series ME EQUIPMENT as recommended below, according to the maximum output power of the communications equipment.
  • Page 43 Via Croazia 2 – 33100 Udine – Italy Tel. +39.0432.621621 Fax +39.0432.621620 Technical assistance : Tel. +39.0432.621699 www.chinesport.it...

This manual is also suitable for:

Fisiolaser ird 2