Maintenance of the roof air conditioner
Interval
Inspection/maintenance
Regularly
Clean the filter of the air discharge unit:
9
➤ Insert a flat screwdriver or knife into the handle (1) to pull the
➤ Remove the filters by hand.
➤ Clean the filters with a detergent solution and let it dry.
➤ Slide the dry filters back in.
Once per year
Check the profile seals:
➤ Check the seal between the roof air conditioner and the roof of the
Once per year
Have the heat exchanger serviced:
➤ Have the heat exchanger of the roof air conditioner serviced by
Once per year
Check the fastening bolt tightness:
➤ Check the fastening bolts are tightened to the correct torque and
More information https://www.caravansplus.com.au
22
2
1
filters (2) slightly out.
vehicle for cracks and other damage.
specialist workshop.
adjust if necessary.