Dometic Harrier Plus HP36H401RIY Installation Manual

Dometic Harrier Plus HP36H401RIY Installation Manual

Air conditioning roof unit
Hide thumbs Also See for Harrier Plus HP36H401RIY:

Advertisement

CLIMATE CONTROL
HARRIER
Harrier Lite HL36H401RI, HL36H401RIY
Harrier Plus HP36H401RI, HP36H401RIY
Air conditioning roof unit
EN
Installation Manual

Advertisement

Table of Contents
loading

Summary of Contents for Dometic Harrier Plus HP36H401RIY

  • Page 1 CLIMATE CONTROL HARRIER Harrier Lite HL36H401RI, HL36H401RIY Harrier Plus HP36H401RI, HP36H401RIY Air conditioning roof unit Installation Manual...
  • Page 2 © 2022 Dometic Group. The visual appearance of the contents of this manual is protected by copyright and design law. The underlying technical design and the products contained herein may be protected by design, patent or be patent pending. The trademarks mentioned in this manual...
  • Page 3: Table Of Contents

    This product manual, including the instructions, guidelines, and warnings, and related documentation, may be subject to changes and updates. For up-to-date prod- uct information, please visit documents.dometic.com. Table of contents Explanation of symbols .
  • Page 4: Safety And Installation Instructions

    Safety and installation instructions Harrier series Safety and installation instructions Please observe the prescribed safety instructions and stipulations from the vehicle manufacturer and service workshops. Handling the device WARNING! • Installation and repair of the roof air conditioner may only be carried out by qualified personnel who are familiar with the risks involved and the relevant regulations.
  • Page 5: Target Group For This Instruction Manual

    Harrier series Target group for this instruction manual NOTE • Please ask your vehicle manufacturer if a technical inspection is required after fitting an air conditioner and whether the height entered in the vehicle docu- ments needs to be altered: –...
  • Page 6: Scope Of Delivery

    Scope of delivery Harrier series Scope of delivery No. in Quantity Description fig. 1 Roof air conditioner Roof plate Air distribution box (ADB) ADB center cover Duct sections Cable connectors Fastening bolts Remote control Accessories Available as accessories (not included in the scope of delivery): Description Ref.
  • Page 7: Intended Use

    • Alterations to the product without express permission from the manufacturer • Use for purposes other than those described in this manual Dometic reserves the right to change product appearance and product specifications. NOTE You can find additional information on roof air conditioners in the operating...
  • Page 8: Labels

    Labels Harrier series Labels Product data label location on rooftop unit ADB data label inside the ADB centre cover Labels are attached to the Harrier series roof air conditioners. These labels provide the user and fitter with information on specifications of the device. The roof air conditioner label is located on the side of the electronics box and can be seen through the side vent.
  • Page 9 Harrier series Installation CAUTION! Beware of injury • Improper installation of the roof air conditioner can result in irreparable damage to the device and put the safety of the user at risk. • The manufacturer assumes no liability for malfunctions and for the safety of the roof air conditioner, especially for injury and/or damage to property, if the roof air conditioner is not fitted in accordance with these installation instructions.
  • Page 10 Installation Harrier series 8.1.2 Note on installation location • Before installing the roof air conditioner, check whether any vehicle compo- nents could be damaged by the installation of the roof air conditioner (such as lamps, cupboards, doors). • Before installation, find out (by consulting the manufacturer of the vehicle) whether the construction is designed for the static weight and the loads of the air conditioner when the vehicle is in motion.
  • Page 11 Harrier series Installation • Using an existing opening in the vehicle such as a roof hatch or replacing an old air conditioner (chapter “Installing in an existing opening” on page 13). Making a new opening Harrier Lite Harrier Plus 1070 See fig.
  • Page 12 Installation Harrier series See fig. 6 ➤ Drill out the corners (A). ➤ Carefully cut out the opening on the roof using a keyhole saw or a similar tool (B). ➤ Make sure no electrical power cables are damaged. See fig. 7 ➤...
  • Page 13 Harrier series Installation Installing in an existing opening NOTE • Existing roof hatch openings in accordance with fig. 8 are suitable for installing the roof air conditioner. • Dispose of all waste material, glue, silicone and seals separately. Observe the disposal guidelines. •...
  • Page 14 Installation Harrier series See fig. 0 NOTICE! Observe the sealant manufacturer’s instructions. ➤ Seal the screw holes and recesses with a flexible non-hardening butyl sealing compound (e.g. SikaLastomer-710, Selleys Butyl Mastic, Bostik ezycaulk butyl sealant, or similar products). Laying the connecting cables DANGER! Danger of electrocution Make sure there is no voltage at electrically operated components before car- rying out work on them!
  • Page 15 Harrier series Installation See fig. a ➤ Make an opening on one side in order to feed through the electrical power supply cable. ➤ Feed the 240 Vw cable through the opening into the vehicle interior. Installing the roof air conditioner ADB NOTICE! Risk of damage Observe the structural strength of the roof of the vehicle.
  • Page 16 Installation Harrier series See fig. c ➤ Lift the roof air conditioner onto the roof of the vehicle. ➤ Position the roof air conditioner onto the roof plate and align into the groove in the base pan. Observe the direction of travel.
  • Page 17 Harrier series Installation 8.5.1 Attaching the roof air conditioner See fig. d ➤ Use the corners of the front of the base pan to help align the unit with the roof plate.
  • Page 18 Installation Harrier series 8.5.2 Electrical connection ye/gn ye/gn AC-L AC-N COMU bk wh ye/gn ye/gn ye/gn ye/gn Item Description 220 – 240 Vw mains Evaporator plate Communication wire Heatsink metal net Condenser plate Reversing valve Inverter compressor Fan evaporator Fan condenser Out air sensor Evaporator sensor Condenser sensor...
  • Page 19 Harrier series Installation See fig. f 8.5.3 Mains cable ➤ Connect the roof air conditioner with the mains voltage supply. Connect the cables (1) to a cable connector (2).
  • Page 20 Installation Harrier series 8.5.4 Communication cable ➤ Pull out the filter slightly to create a gap for the communication cable (3). ➤ Feed the communication cable through the gap and locate the wire in the opening. See fig. g ➤ Stack the duct sections and place against the roof thickness: the duct height should match the roof height.
  • Page 21 Harrier series Installation ➤ Fasten the ADB to the ceiling through to the roof air conditioner with the 4 bolts supplied. 2.5±0.3 Nm See fig. h NOTICE! Risk of damage Tighten to the specified torque. Do not overtighten. ➤ Tighten the screws using a torque spanner and a fastening torque of 2.5 Nm ±0.3 Nm.
  • Page 22 Installation Harrier series See fig. i ➤ Clip the center cover to the ADB. The installation is now completed. Connect to the power and test.
  • Page 23: Technical Data

    Harrier series Technical data Technical data Contains fluorinated greenhouse gases. Hermetically sealed equipment. Harrier Lite Harrier Plus HL36H401RI, HP36H401RI, HL36H401RIY HP36H401RIY Compressor cooling capacity: 3600 W Cooling capacity based on ISO 5151: 2413 W 3028 W Heating capacity based on ISO 5151: 2421 W 3017 W Rated input voltage:...
  • Page 24 YOUR LOCAL YOUR LOCAL DEALER SUPPORT SALES OFFICE dometic.com/dealer dometic.com/contact dometic.com/sales-offices A complete list of Dometic companies, which comprise the Dometic Group, can be found in the public filings of: DOMETIC GROUP AB • Hemvärnsgatan 15 • SE-17154 Solna • Sweden...