Service Fluid

If the Service Fluid level is low, the red light comes on and the message
"Please refill Service Fluid" is displayed on the operating panel.
INFO:
Service Fluid must not be refilled until the device is commissioned.
Service Fluid must only be refilled if the relevant message is displayed on
the operating panel.
Use original EFOY Service Fluid only.
Swtich off the EFOY fuel cell before refilling with Service Fluid.
Disconnect the charge line.
Please ensure that no dirt or foreign bodies enter the fill opening.
4.
Screw the fuel cartridge connection
onto the new EFOY fuel cartridge.
5.
Press [ ][ ] on the operating panel
to select the installed fuel cartridge.
6.
Press [ok] to confirm your selection.
ok
!