EFOY Comfort Series User Manual page 76

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 48
Operation
Battery parameters
menu
menu
CAUTION!
Incorrectly set operating parameters may damage the device. This may
nullify your warranty.
Please only use the precise values permitted for the battery parameters
and battery protection settings.
Battery parameters
Switch-on delay
You can select the following menu options
in the "Battery parameters" menu:
-
Switch-on delay
ok
-
Switch-on voltage
!
-
Switch-off voltage
-
Switch-off current
-
Absorption time
ok
-
Factory defaults
!
This option allows you to undo all of the
battery parameter settings. Press [ok]
to confirm or [ ] to cancel.
Press [ok] to access each menu.
Function
The EFOY fuel cell does not start immediately if
the switch-on voltage only drops below the set
threshold level temporarily. The device only
starts automatically if the switch-on voltage is
still below this threshold level after the switch-
on delay of 60 seconds. For example, with the
factory default of 12.3 V, the switch-on voltage
must drop below 12.3 V for at least 60 seconds
in order for the EFOY fuel cell to start.
If power consumers with a high rate of power
consumption are operated temporarily, this
value must be set in accordance with the
operating times of these consumers.
Page 75