Display lines
Note
The first line indicates the selected channel
number (CH2)
operation mode (SG2)
name (Machine 1)
The second line indicates
either the pressure levels at the pressure transmitter channel (L1:118bar L2:005bar)
or the pressure switch channel switch status (PS1 close PS2 open)
The third line indicates the selected channel
line control (L1on)
pump control (ON/S)
elapsed pumping time (00025s)
The fourth line indicates
the function key texts
Display function keys
Key
Line
Pump
Esc
13401BEN.doc
The texts in brackets are sample display texts.
Description
Line control (Off / L1on / L2on)
Press key to switch line control on.
Off: no line controls
L1on: line control for line 1
L2on: line control for line 2
Note
In dual-line MultiLube –system ML2 pressure from line 2
discharges by switching on line control L1on.
Pump control (Off / ON/S / ON/F)
Press key to start and stop the pump.
Off: pump is stopped / not operating
ON/S: pump is running on switch control
ON/F: pump is running on forced control
Note
Oil lubrication system can use only forced control.
Note
The pump does not start, if line control is not switched on.
Back to basic display
SAFEGREASE, SAFEOIL, MULTILUBE
ST-1340
8 (19)
27.12.2004 Rev. 1B