4.2 Settings display

Note
Channel set values can be displayed by selecting Page at the basic display.
CH2 SG2 Machine 1
Tc=024h00min P=0230s
Hp=120bar Lp=050bar
Chnl Othr
Figure 8.
Display lines
Note
The first line indicates the selected channel
number (CH2)
operation mode (SG2)
name (Machine 1)
The second line indicates the selected channel
set lubrication cycle (Tc=024h00min). Lubrication cycle is interval time multiplied by
two (2).
set maximum pressurization time (P=0230s)
The third line indicates the selected pressure transmitter channel
pressure high limit (Hp=120bar)
pressure low limit (Lp=050bar)
Note
The fourth line indicates
the function key texts
13401BEN.doc
Set value password is 1340 or 1440.
Set
Settings display
The texts in brackets are sample display texts.
For pressure switch channel, this line is blank.
SAFEGREASE, SAFEOIL, MULTILUBE
ST-1340
Esc
13 (19)
27.12.2004 Rev. 1B