5
Commissioning
Mounting position
Due to the pilot burner falling due to vibrations for overhead assembly with sliding
flange!
 Overhead assembly is only permitted with welded flange!
Fig. 5-1 Possible installation situations
1 Mounting angle in relation to the hori-
2 Upright or vertical mounting position
Plan supply lines
Control devices are to be provided for the gas and air supply.
DANGER!
zontal 0...90°. A corresponding adapter
for angled assembly must be present
on-site.
31
3 Not permissible with sliding flange.
Overhead assembly is permissible
solely with a welded flange!
4 Level or horizontal mounting position