Performance Settings; Description Of Controls; Limiting Ventilation Capacity; Equipment Maintenance By The User - BPC DUPLEX 250 Easy Use, Maintenance And Installation Manual

Table of Contents

Advertisement

An option to increase ventilation capacity using external switches, e.g. in the bathroom or toilet.
An option to limit maximum and minimum ventilation capacity.
Equipment operation indication.

Performance settings

2.6.
Identical to those the table in chapter 2.1. The HVAC unit operates according to settings by the controller, the closing of e xternal
inputs from the bathroom, toilet or kitchen, or an air quality sensor.

Description of controls

2.7.
Selecting ventilation capacity or starting / stopping operation
Rotate the controller to set the required ventilation capacity in a range of 10–100 %.
-
Ventilation is stopped by turning the controller anti-clockwise until it reaches the symbol "0" at the end position; however the
-
equipment still responds to external commands – see the chapter 3.3.
Starting air reheat
The setting applies only provided that an external air heater with its own thermostat is fitted.
-
Start air reheat by pressing the button in the right hand bottom corner of the controller next to the thermometer symbol (stop by
-
pressing again)
Note:
Air is reheated only when the unit is running.
-
The thermostat temperature is set by the technician in charge of installing the equipment in a range between 15 and 35 °C
-

Limiting ventilation capacity

2.8.
Removing the rotary controller provides access to other control features, the turning of which sets the minimum and maximum
ventilation capacity levels (a full range of 0-100 % is set by the manufacturer).
3 .
E q u i p m e n t m a i n t e n a n c e b y t h e u s e r

Basic instructions, filter replacement, maintenance and cleaning

3.1.
Maintenance involves visually checking the equipment, regularly replacing filters and cleaning the heat recovery exchanger.
During maintenance observe the rules of personal hygiene and use protective equipment (a face mask, packaging for
contaminated filters).
Before starting maintenance of the unit, always disconnect the equipment from power supply by unplugging the plug
from the power socket.
During maintenance observe safety instructions contained in the manual ("Important notice"), follow the fundamental rules of
safe work and use suitable means of accessing HVAC equipment (ladders, stepladders).

G4 / F7 filter cloth replacement

3.2.
You should replace the filter cloth only provided that you do not suffer from allergic reactions to dust particles. Do not conduct
replacement when people with such a level of sensitivity are present.
Replace the filter cloth from the filter frame in a well-ventilated area or out of doors.
Before removing the frame with cloth, we recommend that you should have an air-tight bag (a plastic carrier bag etc.) ready to
carry the frame to a suitable area to conduct replacement and subsequently use it to dispose of the contaminated cloth, e.g. with
common waste.
Replacement is carried out depending on the dust load of the ambient environment between every 500 and 2,000 operation
hours (usually approx. 2 - 3 months). The recommended inspection interval is indicated on the controller's display.
Description of controls:
1.
Ventilation capacity setting
2.
Operation indication
3.
Starting air reheating (if a reheater is installed)
Description:
1.
Setting of min. ventilation capacity
2.
Setting of max. ventilation capacity
10