Installing Batteries - Nonin Onyx Vantage 9590 Instructions For Use Manual

Finger pulse oximeter
Hide thumbs Also See for Onyx Vantage 9590:
Table of Contents

Advertisement

Symbols
Symbol
Caution!
!
Follow Instructions for Use
Authorized Representative in the European
EC
REP
Community
CE Marking indicating conformance to
EC Directive No. 93/42/EEC concerning
medical devices.
Type BF Applied Part (patient isolation from
electrical shock)
Not for continuous monitoring
(no alarm for SpO
Battery orientation
Indicates separate collection for electrical
and electronic equipment (WEEE).
UL Mark for Canada and the United States
with respect to electric shock, fire, and
mechanical hazards only in accordance
with:
• ANSI/AAMI ES60601-1:2005/(R)2012
• ISO 80601-2-61:2011

Installing Batteries

Two 1.5 volt AAA-size batteries power the 9590 for about 6,000 spot checks or 36 hours of operation. Nonin recommends
using alkaline batteries (included with each new device). When batteries are low, the numeric displays flash once per second.
Remove batteries if the device will be stored for more than 30 days. Replace low batteries as soon as possible, using the
instructions below.
WARNING: Before changing batteries, make sure the device is off and is not applied to a digit.
NOTE: Rechargeable batteries may be used; however, they require more frequent replacement.
1. Hold the 9590 as shown in figure A. To release the device's battery tray, press upward and then pull outward slightly with
the thumb.
2. Remove the old batteries from the battery tray. Dispose of the batteries properly.
3. Insert two new 1.5 volt AAA-size batteries. Follow the polarity markings (+ and -) as illustrated in figure B. Proper
positioning of the batteries is essential for operation.
4. Carefully guide the battery tray back onto the device. Press downward and then push inward slightly to re-secure the
battery tray (figure C). Do not force it into place; it fits only when properly positioned.
5. Insert your finger into the device to verify operation. See the Activating the Onyx Vantage 9590 and Verifying Operation
section for more information.
A
Description
)
2
and CAN/CSA-C22.2 No. 60601-1:14
Symbol
SN
Serial number
Catalogue number
REF
REF
Quantity
QTY
QTY
Manufacturer
Country of manufacture
US
Date of manufacture
Protected against spraying water and against
IP33
access to hazardous parts with a tool, per IEC
60529.
Storage/shipping temperature range
Non-ionizing electromagnetic radiation.
Equipment includes RF transmitters; interference
may occur in the vicinity of equipment marked
with this symbol.
RoHS compliant (China)
Federal law (USA) restricts this device to sale by
or on the order of a licensed practitioner.
B
Description
C
2