Fostoria SUN-MITE FES Series Manual page 8

Portable electric heaters, suspended electric heaters
Table of Contents

Advertisement

FES-1524-3E & YES-1524-3E
240 VOLTS 60HZ
3-PHASE 15KW
L1 L2 L3
MAXIMUM OVERCURRENT PROTECTION 45 AMPS,
GND
CABLE NOT INCLUDED
GROUND LUG
CONTACTOR COIL
L1
L1
T1
L2
L2
T2
L3
L3
T3
L2
6
4
NON-CYCLING
L1
CYCLING
L1
FES-1548-3E & YES-1548-3E
480 VOLTS 60HZ
3-PHASE 15KW
L1 L2 L3
MAXIMUM OVERCURRENT PROTECTION 25 AMPS,
GND
CABLE NOT INCLUDED
GROUND LUG
CONTACTOR COIL
L1
L1
T1
L2
L2
T2
L3
L3
T3
L2
6
4
NON-CYCLING
L1
CYCLING
L1
Issue Date: 4-19-02
Rev. Date: 10/18
WIRING (continued)
USE COPPER WIRE ONLY
240V / 2500W ELEMENTS
TYPICAL (6)
FAN
FAN MOTOR
1
3
CONTACTOR
COIL
OVERTEMP SWITCH
USE COPPER WIRE ONLY
240V / 2500W ELEMENTS
TYPICAL (6)
FAN
FAN MOTOR
1
3
CONTACTOR
COIL
OVERTEMP SWITCH
Rev. Level: 21
FES-1520-3A & YES-1520-3A
208 VOLTS 60HZ
3-PHASE 15KW
L1 L2 L3
GND
CABLE NOT INCLUDED
GROUND LUG
CONTACTOR COIL
L1
L1
T1
L2
L2
T2
L3
L3
T3
L2
6
4
NON-CYCLING
L1
L1
FES-1560-3A & YES-1560-3A
600 VOLTS 60HZ
3-PHASE 15KW
L1 L2 L3
GND
CABLE NOT INCLUDED
GROUND LUG
CONTACTOR COIL
L1
L1
T1
L2
L2
T2
L3
L3
T3
L2
6
4
NON-CYCLING
L1
L1
ECO1-7476
OIPM P/N 8997
MAXIMUM OVERCURRENT PROTECTION 55 AMPS,
USE COPPER WIRE ONLY
208V / 2500W ELEMENTS
TYPICAL (6)
FAN
FAN MOTOR
1
3
CONTACTOR
CYCLING
OVERTEMP SWITCH
MAXIMUM OVERCURRENT PROTECTION 20 AMPS,
USE COPPER WIRE ONLY
300V / 2500W ELEMENTS
TYPICAL (6)
FAN
FAN MOTOR
1
3
CONTACTOR
CYCLING
OVERTEMP SWITCH
8 OF 14