SPECIFICATIONS

SPECIFICATIONS

SYSTEM

Specifications for the various components are shown below.
SystemType
Solar flow and return connection:
PTR valve connection:
Cold inlet connection:
Hot outlet connection:
PTR valve setting
Rating of PTR Valve supplied
Expansion Control Valve (ECV) setting
Max supply pressure with ECV
Max supply pressure without ECV
Pressure limiting valve rating
(supplied by installer if required)
Flow Control
A variable speed pump controls the water flow rate through the collectors and storage cylinder to optimise the
performance of the system�
Solar Controller
There are two types of Rinnai solar controller available for residential solar hot water systems:
The Standard Controller is used with all gas boosted systems and electric boosted systems with an
independently controlled element� It should not be used with an electric tank with a mid sensor port�
The Deluxe controller is used for systems with an electric element tank that has a mid sensor port�
Both controllers operate of the pump to optimize solar energy collection and stop energy collection when the
cylinder is full of hot water� They both also have the option of Pumped Frost Protection�
The Deluxe controller has the additional functionality of controlling the operation of the electric element for tank
sterilisation and for optimal performance�
For full details see the solar controller manual�

SOLAR COLLECTORS

Full specifications for the solar collectors can be found in the installation manual provided in the collector installation
kit� The following information is provided to assist in completing the installation
ENDURO &
EXCELSIOR
Potential Solar
Output at PTR
relief conditions
FOR MORE INFORMATION ON
Frost Protection
FROST PROTECTION REFER TO
Rinnai
Glass Lined
Cylinders
SG175,SG215,
SE250AB,SE250AM
SE315AB,SE315AM
1000 kPa
850 kPa
680 kPa
800 kPa
500 kPa
ENDURO XL
1�25 kW
1�40 kW
WARRANTY BOOKLET
Glass Lined
Cylinders
SG270SL,SG320SL
Rp ½
Rp ½
Rp ¾
Rp ¾
10 kW
Power must be on at the pump and the solar controller
must be in Pumped Frost Protection Mode�
See the solar controller manual for more details�
FOR MORE INFORMATION ON FROST
PROTECTION REFER TO WARRANTY BOOKLET
12
All Stainless Steel
160,250,315
Rp ½
Rp ½
Rp ¾
Rp ¾
850 kPa
10 kW
700 kPa
550 kPa
680 kPa
500 kPa
Evacuated Tubes
20 tubes - 1�30 kW
25 tubes - 1�63 kW
30 tubes - 1�96 kW
Cylinders
Rp ½
Rp ¾
Rp ¾
Rp ¾
850 kPa
10 kW
700 kPa
550 kPa
700 kPa
500 kPa
Split Solar OIM