Chengdu Ebyte Electronic Technology Co,;Ltd
7.1 Default Parameter
Model
E70-915T30S
7.2 Reading Operating Parameters
Instruction format
C1+C1+C1
7.3 Reading Version Number
Instruction format
C3+C3+C3
7.4 Reset Instruction
Instruction format
C4+C4+C4
7.5 Parameter Setting Instruction
No.
Item
0
HEAD
Fix 0xC0 or 0xC2, it means this frame data is control command
1
ADDH
2
ADDL
7
3
SPED
0
0
Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co,;Ltd
Frequency
Address
915MHz
0x0000
In configuration mode(M0=1, M1=1, M2=0) ,
User gives the module instruction (HEX format): C1 C1 C1,
Module returns the present configuration parameters.
For example, C0 00 00 18 4E 1C.
In configuration mode(M0=1, M1=1, M2=0),
User gives the module instruction (HEX format): C3 C3 C3,
Module returns its present version number, for example C3 0071 XX1 XX2 XX3 XX4 XX5.
70 here means the module model (E70 series); xx1 is the version number and XX2 XX3 XX4 XX5 refers
to the other module features.
In configuration mode(M0=1, M1=1, M2=0),
User gives the module instruction (HEX format): C4 C4 C4, the module resets for one time. During
the reset process, the module will conduct self-check, AUX outputs low level. After reset completed,
the AUX outputs high level, then the module starts to work regularly when the working mode can be
switched or be given another instruction.
Description
High address byte of module(the default 00H)
Low address byte of module(the default 00H)
6
UART parity bit
8N1(Default )
0
1
Default parameter values:C0 00 00 18 44 1C
Channel
Air data rate
0x10
2.5K
Description
Description
Description
8O1
E70-915T30S user manual
Baud rate
Parity
9600
8N1
Notes
Must be 0xC0 or 0xC2
C0: Save the parameters when power-down
C2: Do not save the parameters when power-down
00H-FFH
00H-FFH
UART mode can be different between
communication parties
Transmitting
power
1W
17