Sleep Mode (Mode 7); Instruction Format - Ebyte E70-915T30S User Manual

Cc1310 915mhz 1w smd wireless module
Hide thumbs Also See for E70-915T30S:
Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co,;Ltd
Transmitting
Transmission is not available.
Receiving
Receiving is available.
Baud rate & air
Under this mode, the baud rate and air data rate are independent, both receiver and transmitter can have different baud rate
data rate
but same air data rate.
The module works under WOR status, it wakes up periodically and monitors the wireless data packets, when data packet
Advantage
monitored, the module enters receiving mode and receives complete data packets, and outputs the data through serial port,
and then enters WOR status again, which can save power consumption significantly.
Disadvantage
Transmission is not available under this mode, the module must be switched to other mode for data transmission.
Applications
Applicable for those devices which have requirement on power consumption and need to receive data.
Note
It can only receive the data sent from the transmitter under mode 4.

6.9 Sleep Mode (Mode 7)

Status
M0=1 M1=1 M2=1
Transmitting
Transmitting is not available.
Receiving
Receiving is not available.
Others
Other functions of the module are closed, only can quit sleep mode by switching the M0, M1 and M2 status.

7.Instruction Format

In configuration mode(Mode 3:M0=1, M1=1, M2=0), it supports instructions below.
(Only support 9600 and 8N1 format when setting)
No.
Instruction format
1
C0 + working parameters
2
C1+C1+C1
3
C2 + working parameters
4
C3+C3+C3
5
C4+C4+C4
Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co,;Ltd
C0 + 5 bytes working parameters are sent in hexadecimal format. 6 bytes in total and must be sent in
succession.
( Save the parameters when power-down )
Three C1 are sent in hexadecimal format. The module returns the saved parameters and must be sent
in succession.
C2 + 5 bytes working parameters are sent in hexadecimal format. 6 bytes in total and must be sent in
succession. ( Do not save the parameters when power-down )
Three C3 are sent in hexadecimal format. The module returns the version information and they must
be sent in succession.
Three C4 are sent in hexadecimal format. The module will reset one time and they must be sent in
succession.