ABB EDS500 Series Function Manual page 99

Ethernet & dsl switches
Hide thumbs Also See for EDS500 Series:
Table of Contents

Advertisement

Functions
Object name
OID
Table 52:
Objects of the group abb->abbMgmt->alarm->enabledAlarmstable (table index -
ifIndex.alarmId)
Object name
OID
timeRegistered
1.3.6.1.4.1.21939.9.9.1.1.2.a.
b.c.d
timeLeftToExpire
1.3.6.1.4.1.21939.9.9.1.1.3.a.
b.c.d
mgrVersion
1.3.6.1.4.1.21939.9.9.1.1.4.a.
b.c.d
sendSnmpNotification
1.3.6.1.4.1.21939.9.9.1.1.7.a.
b.c.d
snmpNotificationPort
1.3.6.1.4.1.21939.9.9.1.1.8.a.
b.c.d
sendSyslogSeverity
1.3.6.1.4.1.21939.9.9.1.1.9.a.
b.c.d
syslogPort
1.3.6.1.4.1.21939.9.9.1.1.10.a
.b.c.d
sysUpTime
1.3.6.1.4.1.21939.9.9.1.1.11.a
.b.c.d
Table 53:
Objects of the group abb->abbMgmt->mgr->mgrTable (table index - ip)
Object name
OID
tcpReceiveIdle
1.3.6.1.4.1.21939.9.10.3.1.6.a .b.c.d.x.e.f.g.h.y
Table 54:
Objects of the group abb->abbMgmt->tcpExt->tcpTable (table index -
tcpLocalIp.tcpLocalPort.tcpRemoteIp-tcpRemotePort).
1KGT151021 V000 1
Read object
–levelError (2)
Read object
System Uptime at the time of
first login
Number of seconds before
manager will be discarded
freely assignable 32 bit ver-
sion field
Manager receives traps:
–no (0)
–send (1)
UDP port for SNMP traps
Bits 0-2: minimum severity for
Syslog messages
UDP port for Syslog mes-
sages
Convenience object: return
the System Uptime (like MIB-2
sys- UpTime)
Read object
TCP inactivity in 100 ms
SNMP Network Management
Write object
Write object
Login and refresh of the man-
ager: Number of seconds but
maximum 3600
sets a freely assignable 32 bit
version field
Sets the preferred Manager
setting for traps
Sets the UDP port for SNMP
traps
Default value: 162
Sets the minimum severity for
Syslog messages (bits 0-2). Bit
3 activates the sending of Sys-
log.
Sets the UDP port for Syslog
messages
ignored
Write object
99