Configuration Methods
IP Setting
IP Address
Subnet mask
Gateway IP address
Table 2:
Default values for IP
For further configuration you should first check the network connectivity e.g. with ICMP echo
request ("ping"). Use the device IP address as target address.
2.1.3

Configuration via Telnet

With the help of a Telnet client program the managment console can be accessed.
Prerequisite is the reachability of the device via the IP network (Chapter 2.1.2, "Configuration
via the IP Network"). Common programs are PuTTY, HyperTerminal or Microsoft Windows
Telnet.exe.
Target address is the device IP address (refer to "Tab. 2: Default values for IP").
Default configuration:
In default configuration Telnet is disabled.
Depending on the system login mode it may be necessary to enter a user name and/or
password before the Telnet access to the management console is granted (refer to "User
Authentication").
The default value for loginmode is: password. The default login password is empty.
Parameter
Loginmode password
Loginmode radius
Table 3:
Login with Telnet
After successful login Telnet offers access to the command line interface (CLI) (handling see
Chapter 2.2, "Handling of the Command Line Interface (CLI)").
2.1.4

Configuration via SSH

The command line interface (CLI) can be accessed with the help of a SSH client program.
Prerequisite is the reachability of the device via the IP network (Chapter 2.1.2, "Configuration
via the IP Network")
Common programs are Tera Term, PuTTY or OpenSSH.
Target address is the device IP address (refer to "Tab. 2: Default values for IP").
Default configuration:
In default configuration SSH is enabled.
Depending on the system login mode it may be necessary to enter a user name and/or
password before the SSH access is granted to the command line interface (CLI), (refer to
Chapter 2.3, "User Authentication").
The default value for loginmode is "password". The default login password is empty.
10
Parameter
10.0.0.2
255.0.0.0
10.0.0.1
User name
-
RADIUS user
Functions
User password
Login password
RADIUS password