Description of the display values
A : 0 1
SM1: Actual
DHW temperature
Solar cylinder
SM2: DHW
Actual temperature
Solar cylinder 1
A : 0 2
SM1: Maximum
DHW temperature
Solar cylinder
SM2: Maximum
DHW temperature
Solar cylinder 1
A : 0 3
SM1: Collector temperature
SM2: Collector temperature,
collector array 1
A : 0 4
SM1: Maximum collector
temperature
SM2: Maximum collector
temperature
Collector array 1
A : 0 5
SM1: Return temperature
SM2: Input E1
A : 0 6
Solar circuit flow rate
10
Display level
SM1: The current temperature of the solar cylinder at the level of
the solar indirect coil is displayed.
SM2: The current temperature of solar cylinder 1 at the level of
the solar indirect coil is displayed.
SM1: The maximum DHW temperature over the course of 24 hours
is displayed.
SM2: The maximum DHW temperature of cylinder 1 over the
course of 24 hours is displayed.
This value is reset every 24 hours.
SM1: The current temperature captured at the outlet (flow) of the
collector or collector array is displayed.
SM2: The current temperature captured at the outlet (flow) of the
collector or collector array 1 is displayed.
SM1: The maximum collector temperature over the course of
24 hours is displayed.
SM2: The maximum collector temperature of collector array 1
over the course of 24 hours is displayed.
This value is reset every 24 hours.
SM1: The current temperature of the solar circuit return is displayed.
This value is required for calculating the yield.
SM2: The current value captured by the sensor connected
to input E1 is displayed. Subject to the configuration
set at the SM2, this may be the return temperature, the
actual DHW temperature of solar cylinder 2, the actual
DHW temperature of solar cylinder 3 or the heating
temperature.
This value will only be displayed if a temperature sensor
has been connected.
SM1/ The current flow rate in l/min (litres per minute is displayed.
SM2: This display is only shown if value 1 or 2 has been
selected for parameter 08 (capturing the amount of heat).
This value is required for calculating the yield.