Magnum DS - Product specific information
Table 6 . Magnum DS switchgear class UL 1066 low voltage power circuit breakers ANSI continued
breaker
3
type
catalog
Frame
position
1
amperes
1–6
2000
MDN-620
1
MDN-C20
MDS-620
1
MDS-820
MDS-C20
1
MDS-H20
MDS-L20
2
1
MDS-X20
3
2500
MDS-625
1
MDS-825
1
MDS-C25
MDS-H25
1
3200
MDS-632
MDS-832
1
MDS-C32
MDS-H32
1
MDS-X32
3
4000
MDS-840
1
MDS-C40
MDS-H40
1
MDS-X40
3
1
MDN-640
MDN-840
1
MDN-C40
1
MDD-X40
1
5000
MDS-850
MDD-X50
1
MDS-C50
MDS-H50
Double
1
MDS-X50
3 5
Double
1
Interrupting ratings shown based on breaker equipped with integral digitrip rms trip unit . Interruption ratings for non-automatic breakers are equal to
1
the published withstand rating .
Magnum MDSL current limiting power circuit breaker with integral current limiters . Current limiter selected determines short time and fixed instanta-
1
2
neous trip rating .
Magnum MDSX current limiting power circuit breaker with fast opening contacts .
3
1
Product to be tested . Contact Eaton for product rating .
4
Breaker applied in a tested fan cooled enclosure .
5
1
Not released .
6
1
1
1
1
1
22
MaGnuM PRoDuct GuiDe CA013002EN—April 2017
Courtesy of NationalSwitchgear.com
rms Symmetrical current ratings ka 50/60 Hz
interruption
interruption
Frame
rating at
rating at
type
254 Vac
508 Vac
Narrow
65
65
Narrow
100
100
Standard
65
65
Standard
85
85
Standard
100
100
Standard
130
130
Standard
200
200
Standard
200
200
Standard
65
65
Standard
85
85
Standard
100
100
Standard
130
130
Standard
65
65
Standard
85
85
Standard
100
100
Standard
130
130
Double
200
200
Double
85
85
Double
100
100
Double
130
130
Double
200
200
Double
65
65
Narrow
Double
85
85
Narrow
Double
100
100
Narrow
Double
200
200
Double
85
85
Double
200
200
Double
100
100
130
130
200
200
1
Short
time
Short
withstand
time
interruption
rating
withstand
rating at
@254/
rating
635 Vac
508Vac
@635Vac
65
65
65
65
35
35
65
65
65
85
85
85
100
85
85
130
85
85
200
2
2
65
30
30
65
65
65
85
85
85
100
100
85
130
85
85
65
65
65
85
85
85
100
85
85
130
85
85
50
50
4
85
85
85
100
100
100
130
130
130
50
50
4
65
65
65
65
85
65
65
100
65
100
100
100
85
85
85
100
100
100
100
100
100
130
130
130
50
50
4
www.eaton.com
available
current
sensor
and rating
plugs for
digitrip rms
Fixed
trip unit
internal
(establishes
inst
breaker i
Poles
n
trip
rating)
available
n/a
200, 250, 300,
3 & 4
400, 600, 800,
18xIn
3 & 4
1000, 1200,
n/a
1600, 2000
3 & 4
n/a
3 & 4
85
3 & 4
85
3
n/a
3
30
3
n/a
200, 250, 300,
3 & 4
400, 600, 800,
n/a
3 & 4
1000, 1200,
85
3 & 4
1600, 2000,
2500
85
3
n/a
200, 250, 300,
3 & 4
400, 600, 800,
n/a
3 & 4
1000, 1200,
85
3 & 4
1600, 2000,
2500, 3200
85
3
50
3
n/a
2000, 2500,
3 & 4
3200, 4000
n/a
3 & 4
n/a
3
50
3
n/a
3 & 4
n/a
3 & 4
n/a
3 & 4
n/a
3
n/a
2500, 3200,
3 & 4
4000, 5000
n/a
3
n/a
3 & 4
n/a
3
50
3