Magnum DS ANSI breaker product family continued
(15 through 25)
Shunt Trip (ST)
N
=
None
A
=
110–127 Vac/Vdc
=
208–240 Vac/Vdc
R
=
24 Vdc
C
=
48 Vdc
H
=
110–127 Vac/Vdc
B
(100% duty)
=
220–250 Vac/Vdc
S
(100% duty)
=
24 Vdc (100% duty)
D
K
=
48 Vdc (100% duty)
J
=
60 Vdc (100% duty)
6
=
60 Vdc
Motor operator
M
=
Manual operated
N
=
110–125 Vac (5-sec)
W
=
110–125 Vdc (5-sec)
T
=
220–250 Vdc (5-sec)
P
=
208–277 Vac (5-sec)
L
=
24 Vdc (5-sec)
K
=
48 Vdc (5-sec)
S
=
60 Vdc (5-sec)
1
=
110–125 Vac (3-sec)
2
=
220–250 Vac (3-sec)
4
=
24 Vdc (3-sec)
8
=
48 Vdc (3-sec)
5
=
110–125 Vdc (3-sec)
9
=
220–250 Vdc (3-sec)
Spring Release Device
(SRD)
N
=
None
=
110–127 Vac/Vdc
A
=
208–240 Vac/Vdc
R
=
24 Vdc
C
=
48 Vdc
H
=
60 Vdc
S
Courtesy of NationalSwitchgear.com
A W C H N E H K L A X
Undervoltage Release (UVR)
or 2nd Shunt Trip (ST)
N
=
None
A
=
UVR (110–127 Vac)
R
=
UVR (208–240 Vac)
C
=
UVR (24 Vdc)
H
=
UVR (48 Vdc)
D
=
UVR (60 Vdc)
E
=
UVR (110–125 Vdc)
F
=
UVR (220–250 Vdc)
G
=
UVR (32 Vdc)
X
=
UVR (380–415 Vac)
J
=
UVR (480 Vac)
K
=
UVR (600 Vac)
1
=
2
ST (110–127 Vac Vdc)
nd
2
=
2
ST (208–250 Vac Vdc)
nd
3
=
2
ST (24 Vdc)
nd
4
=
2
ST (48 Vdc)
nd
6
=
2
ST (60 Vdc)
nd
B
=
2
ST (110–127 Vac/
nd
Vdc 100% duty)
O
=
2
ST (220–250 Vac/
nd
Vdc 100% duty)
I
=
2
ST (24 Vdc 100% duty)
nd
Q
=
2
ST (48 Vdc 100% duty)
nd
9
=
2
ST (60 Vdc 100% duty)
nd
Auxiliary switch
N
=
None
2
=
2A/2B
4
=
4A/4B
6
=
6A/6B
Bell Alarms Switch (OTS) with
2a/2b contacts and/or mechanical
trip indicator
Mech.
OTS
inter-
switch
Mech.
lock for
with two
trip
manual
form C
indicator
reset
contacts
E
=
No
No
N
=
Yes
No
No
Y
=
Yes
No
Yes
M
=
Yes
Yes
No
L
=
Yes
Yes
Yes
F
=
Yes
No
Yes with
24V reset
G
=
Yes
No
Yes with
120V
reset
H
=
Yes
No
Yes with
240V
reset
I
=
Yes
Yes
Yes with
24V reset
J
=
Yes
Yes
Yes with
120V
reset
K
=
Yes
Yes
Yes with
240V
reset
MaGnuM PRoDuct GuiDe
Magnum DS - Product specific information
Padlock provisions for blocking
close and/or open ACB manual
pushbuttons
=
None
N
=
Metal (block close and open)
M
=
Plastic (block close and open)
P
=
Metal (block close only)
C
=
Plastic (block close only)
H
=
Metal swbd lock-off
S
(block close, depress open)
Operations counter and/
or keylock provisions
Keylock
Counter
provisions
N
=
No counter
No locks
K
=
No counter
Kirk lock
C
=
No counter
Castell lock
R
=
No counter
Ronis lock
S
=
No counter
CES lock
A
=
Counter
No lock
Y
=
Counter
Kirk lock
L
=
Counter
Castell lock
H
=
Counter
Ronis lock
indicator
E
=
Counter
CES lock
Latch check switch/trip unit
metering voltage connection for
digitrip 1150 trip unit
Latch
check
1150 voltage
switch
connection
N =
None
Upper terminals
M =
None
Lower terminals
L =
LCS wired
Upper terminals
to SRD
Y =
LCS Wired
Lower terminals
to SRD
C =
LCS Wired
Upper terminals
External
D =
LCS Wired
Lower terminals
External
CA013002EN—April 2017
Frame use
X = All breakers
Breaker shipping options
and instructions
A
=
Fixed breaker alone with
door kit
B
=
Fixed breaker alone with door
kit and pre-wired
F
=
Fixed breaker alone without
door kit
=
Drawout breaker alone
A
without door frame kit
=
Drawout breaker in cassette
C
(un-wired)
=
Drawout breaker in cassette
P
(shutters)
=
Drawout breaker in cassette
S
(shutters)
W
=
Drawout breaker in cassette
(pre-wired and shutters)
Double frame drawout breakers
cannot ship in cassette without
cassette drawout.
19
www.eaton.com
3
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Magnum ds seriesMagnum iec series

Table of Contents