6

Adjustable Hopper

The hopper is the area on top of Universal JetScan where notes are placed for processing.
The hopper guides are adjustable and feature a series of numerical settings which correlate to
the width of the notes.
To avoid an increase in no calls and feed errors, notes must be processed at the
required hopper-guide setting.
When the desired country is selected, the required numerical setting for the hopper guides
will appear on the display. By using the required numerical setting, there is less opportunity
for notes to shift and cause errors.
Selecting a Country's Currency
To activate the appropriate country's currency for processing, press CNTRY on the main-
operating screen to prompt the following screen:
The screen above only will show country currencies that have been purchased
for the machine in use.
Scroll to the desired country using the arrow keys. When the desired country's currency is
highlighted, press SELCT.
Two-Pocket Universal JetScan

The Basics

Machine is auto-start capable. Feed rollers in hopper rotate inward.
Entanglement and drawing-in hazard.
Do not operate with exposed long hair, neckties, jewelry or loose
clothing.
COUNTRY INFORMATION
COUNTRY 1 :
COUNTRY 2 : EURO
USA