Teleservice of an Ethernet-PLC Technical data Note: this Quick Start Guide applies to REX 300 systems with order numbers ending in 02 (e. g. 700-872-UMT02). There could be differences in functionality in REX 300 devices with order numbers ending in 01.
If you must first change the address of your PC in order to reach the web interface of the REX 300, carry out steps A to C next. These steps are not necessary when you want to load an existing configuration from USB.
Note: if the IP address is to be changed, it must correspond to the address range (subnet mask) of your computer. See steps A to C on page 3. After making the change, restart the REX 300. Quick Start Guide REX 300...
Configuration via Integrated Install Wizards When you wish to use the REX 300 without our myREX24 mediation server, the device can also be set up using the install wizards integrated in the web interface. Access this in the web interface via the the “Wizards“ menu item in the upper right hand corner.
Finally, import the system configuration into the REX 300. There are two ways of transferring a configuration into the REX 300. For further information, see page 7. After a system restart and, dependent on the configuration, the REX 300 registers with myREX24.
Web interface Open the REX 300 web page - see the description “Accessing the Web Interface“ on page 4. Via the menu item “System“ -> “Import/Export“, open the page where you can read in the REX 300 equipment configuration. The option “Restore the Configuration“ is on this page. Using “Search“ select the appropriate file on your local disc.
Using the shDIALUP software and your access data, connect to the myREX24. Here you will see the REX 300 that you have configured. When a REX 300 is logged into the portal, this will be marked with a green circle.
(this LED must light continuously after 110 sec.) indicator light for power supply Factory settings Carry out the following steps to reset the REX 300 back to its factory settings: • Switch on the device • Wait until the Rdy LED flashes •...
Remote Maintenance of an S7-MPI/PROFIBUS-PLC In order to reach an S7-MPI/PROFIBUS-PLC with a REX 300, the following steps must be carried out. (not for REX 300 eco) Install the NETL ink®-S7-NET driver, either from the accompanying CD or download the latest version from the Internet at www.helmholz.com.
CPU, then either a straight-through or crossover Ethernet cable can be used. As soon as a VPN-connection to the REX 300 has been established, the project can be worked on (e.g. transfer hardware project, monitor variables etc.) from the PLC.
Guide be downloaded from or viewed on the www.helmholz.de website. Our customers are very important to us. We look forward to receiving suggestions for improvement and other feedback. Systeme Helmholz GmbH |Phone +49 9135 7380-0 | Fax +49 9135 7380-110 info@helmholz.de | www.helmholz.com...