ICP DAS USA tGW-700 Series User Manual
Hide thumbs Also See for tGW-700 Series:
Table of Contents

Advertisement

Quick Links

ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru
t GW - 7 0 0 Se r ie s
Use r M a n u a l
W a r r a n t y
All products manufactured by ICP DAS are warranted against defective materials for a period of
one year from the date of delivery to the original purchaser.
W a r n in g
ICP DAS assumes no liability for damages consequent to the use of this product. ICP DAS
reserves the right to change this manual at any time without notice. The information furnished
by ICP DAS is believed to be accurate and reliable. However, no responsibility is assumed by
ICP DAS for its use, nor for any infringements of patents or other rights of third parties resulting
from its use.
Copyr igh t
Copyright © 2010 by ICP DAS. All rights are reserved.
Tr a de m a r k
Names are used for identification only and may be registered trademarks of their respective
companies.
t GW - 7 0 0 Se r ie s Use r M a n ua l, Ve r sion 1 .6 , Ju l. 2 0 1 1
1

Advertisement

Table of Contents
loading

Summary of Contents for ICP DAS USA tGW-700 Series

  • Page 1 ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru t GW - 7 0 0 Se r ie s Use r M a n u a l W a r r a n t y All products manufactured by ICP DAS are warranted against defective materials for a period of one year from the date of delivery to the original purchaser.
  • Page 2: Table Of Contents

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru Ta ble of Con t e n t s PACKI N G LI ST ..................................5 M ORE I N FORM ATI ON ................................5 I N TROD UCTI ON ................................6 1 .1 ? ............................7 TH ERN ET...
  • Page 3 ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 4 .1 GW - 7 0 0 W .......................33 OGGI N G I N TO TH E T EB SERVER 4 .2 ..................................35 OM E 4 .3 ..............................36 ETW ORK ETTI N G...
  • Page 4 ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 1 6 . TCP/ I P...................................55 1 7 . UD P ( U ) ........................55 ATAGRAM ROTOCOL APPEN D I X: FAQ ..................................56 OW TO AV OI D A BROW SER ACCESS ERROR TH AT CAUSES A BLAN K PAGE TO BE D I SPLAYED W H EN USI N G I E.
  • Page 5: Packi N G Li St

    Pa ck in g List The shipping package includes t he following it em s: The shipping package includes t he following it em s: One tGW-700 series hardware module One printed Quick Start Guide One software utility CD Qu ick st a r t...
  • Page 6: I N Trod Ucti On

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 1 . I n t r odu ct ion Modbus has become a de facto standard industrial communication protocol, and is now the most commonly available means of connecting industrial electronic devices. Modbus allows for communication between many devices connected to the same RS-485 network, for example, a system that measures temperature and humidity and communicates the results to a computer.
  • Page 7: W H Y Eth Ern Et Soluti On S

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru Comparison Table of Device Servers: Series PPDS Features Virtual COM Programmable Modbus Gateway Multi-client Isolation for Cost-effective, Cost-effective, Remarks Professional Powerful DS-715 Entry-level Entry-level 1 .1 W h y Et h e r n e t Solu t ion s? Nowadays, the Ethernet protocol has become the de-facto standard for local area networks.
  • Page 8: W H Y Web Server Tech N Ology

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 1 .2 W h y W e b Se r ve r Te ch n ology? Web server technology enables configuration of the tGW-700 via a standard web browser interface, e.g.
  • Page 9: H Ard W Are I N Form Ati On

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru H a r dw a r e I n for m a t ion H a r dw a r e I n for m a t ion 2 .1 2 .1 Spe cifica t ion s...
  • Page 10: Features

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 2 .2 Fe a t u r e s Cost-effective Modbus/TCP to RTU/ASCII Gateway Supports Modbus/TCP master and slave Supports Modbus RTU/ASCII master and slave Contains a 32-bit MCU that efficiently handles network traffic 10/100 Base-TX Ethernet, RJ-45 x1 (Auto-negotiating, auto MDI/MDIX, LED Indicators) Redundant power inputs: PoE (IEEE 802.3af, Class 1) and DC jack...
  • Page 11: Tgw - 7 0 0 Fron T V I Ew

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 2 .4 t GW - 7 0 0 Fr ont Vie w Serial COM Port s Robust insulat ed and S1: Syst em LED fire ret ardant case indicat or Operat ing Mode Swit ch...
  • Page 12 Init Mode: Configuration mode Run Mode: Firmware operation mode In the tGW-700 series, the operating mode Switch is in the Run position by default. When updating the tGW-700 firmware, the switch needs to be moved from the Run position to the Init position. The Switch must be returned to the Run position after the update is complete.
  • Page 13: D Im E Nsion S

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 2 .5 D im e nsion s tGW-712 Dimensions: Units: mm Rear View Front View Top View Bottom View Left Side View Right Side View t GW - 7 0 0 Se r ie s Use r M a n ua l, Ve r sion 1 .6 , Ju l. 2 0 1 1...
  • Page 14 ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru tGW-722/732/715/725/735/718/724/734 Dimensions: Units: mm Front View Rear View Top View Left Side View Right Side View Bottom View t GW - 7 0 0 Se r ie s Use r M a n ua l, Ve r sion 1 .6 , Ju l. 2 0 1 1...
  • Page 15: Pin Assign M E N T S

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 2 .6 Pin Assign m e n t s 2 .6 .1 t GW - 7 1 2 Pin Assign m e n t s Assign m e n t s 1- Port 5- wire RS- 232 Module 1- Port 5- wire RS- 232 Module Note: The CTS/RTS pins are reserved...
  • Page 16: Gw- 722 Pin Assignm Ent S

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 2 .6 .2 t GW - 7 2 2 Pin Assign m e n t s 2- Port 5- wire RS- 232 Module Note: The CTS/RTS pins are reserved (no function).
  • Page 17: Gw- 732 Pin Assignm Ent S

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 2 .6 .3 t GW - 7 3 2 Pin Assign m e n t s 3- Port 3- wire RS- 232 Module t GW - 7 0 0 Se r ie s Use r M a n ua l, Ve r sion 1 .6 , Ju l. 2 0 1 1...
  • Page 18: Gw- 715 Pin Assignm Ent S

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 2 .6 .4 t GW - 7 1 5 Pin Assign m e n t s 1- Port 2- wire RS- 485/ 4- Wire RS- 422 Module t GW - 7 0 0 Se r ie s Use r M a n ua l, Ve r sion 1 .6 , Ju l.
  • Page 19: Gw- 725 Pin Assignm Ent S

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 2 .6 .5 t GW - 7 2 5 Pin Assign m e n t s 2- Port 2- wire RS- 485 Module t GW - 7 0 0 Se r ie s Use r M a n ua l, Ve r sion 1 .6 , Ju l. 2 0 1 1...
  • Page 20: Gw- 735 Pin Assignm Ent S

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 2 .6 .6 t GW - 7 3 5 Pin Assign m e n t s 3- Port 2- wire RS- 485 Module t GW - 7 0 0 Se r ie s Use r M a n ua l, Ve r sion 1 .6 , Ju l. 2 0 1 1...
  • Page 21: Gw- 718 Pin Assignm Ent S

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 2 .6 .7 t GW - 7 1 8 Pin Assign m e n t s 1- Port 3- Wire R232 and 2- Wire RS- 485/ 4- Wire RS- 422 Module t GW - 7 0 0 Se r ie s Use r M a n ua l, Ve r sion 1 .6 , Ju l.
  • Page 22: Gw- 724 Pin Assignm Ent S

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 2 .6 .8 t GW - 7 2 4 Pin Assign m e n t s 1- Port 2- Wire RS- 485 and 1- Port 5- Wire RS- 232 Module Note: The CTS/RTS pins are reserved (no function).
  • Page 23: Gw- 734 Pin Assignm Ent S

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 2 .6 .9 t GW - 7 3 4 Pin Assign m e n t s 1- Port 2- Wire RS- 485 and 2- Port 3- Wire R232 Module t GW - 7 0 0 Se r ie s Use r M a n ua l, Ve r sion 1 .6 , Ju l.
  • Page 24: W I Ri N G Notes

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 2 .7 W ir in g N ot e s 2 .7 .1 RS- 2 3 2 W ir in g Con n e ct ion s N ot e : FGN D is t h e fr a m e gr ou n d t ha t is solde r e d t o t h e D B9 m e t a l- sh ie ld.
  • Page 25: Rs- 422 Wiring Connect Ions

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 2 .7 .1 RS- 4 2 2 W ir in g Con n e ct ion s 2 .7 .2 RS- 4 8 5 W ir in g Con n e ct ion s N ot e : You shou ld con n e ct a ll signa l gr ou n ds of RS- 4 2 2 / 4 8 5 de vice s t oge t h e r .
  • Page 26: Setti N G Up Th E Tgw - 7 0 0 M Od Ule

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 3 . Se t t in g u p t h e t GW - 7 0 0 m odu le St e p 1 : Con n e ct in g t h e pow e r a n d H ost PC Make sure the network settings on your PC are functioning correctly.
  • Page 27: Step 2 : I N Stalli N G Th E Mod Bus Uti Li Ty An D E Search Uti Li Ty

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru Make sure the System LED indicator is flashing. St e p 2 : I n st a llin g t h e M odbu s Ut ilit y a n d e Se a r ch Ut ilit y The Modbus Utility is located at: CD: \NAPDOS\Software\Modbus_Utility http://ftp.icpdas.com/pub/cd/tinymodules/napdos/software/modbus_utility/...
  • Page 28: Step 3 : Search For Th E Tgw - 7 0 0 On Th E Eth Ern Et N Etw Ork

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru St e p 3 : Se a r ch for t h e t GW - 7 0 0 on t h e Et h e r n e t n e t w or k Double click the eSearch Utility and click the “Search Servers”...
  • Page 29: Step 4 : Testi N G Your Tgw - 7 0 0

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru St e p 4 : Te st in g your t GW - 7 0 0 4. Wiring to the Modbus device (ex: M-7055D, optional) with your tGW-700 (RS-485 bus). For detailed RS-232/422/485 wiring information, refer to Section 2.7 Wiring Note.
  • Page 30 ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 5. Enter the URL address of tGW-715 in the browser, or click the “Web” button on the eSearch Utility. 6. Enter the password (default: admin) in the login password field, and then click the “Submit”...
  • Page 31 ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 8. Double click the Modbus Utility shortcut on the desktop, and then click the “Modbus/TCP” button. Double-Click 9. Click on the “Client tools” >> “Modbus/TCP Client”. t GW - 7 0 0 Se r ie s Use r M a n ua l, Ve r sion 1 .6 , Ju l. 2 0 1 1...
  • Page 32 ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 10. Enter the IP address of tGW-700 and then click “Connect” button to connect the tGW- 700. 11. Refer to the field "Protocol Description" at the top right of the program. You can send a request command and confirm the response is correct.
  • Page 33: W Eb Con Fi Gurati On

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru W e b Con figu r a t ion Once the tGW-700 module has been correctly configured and is functioning on the network normally, the configuration details can be retrieved or modified using either the eSearch Utility or a standard web browser.
  • Page 34 ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru St e p 3 : En t e r t h e Pa ssw or d After entering the IP address, the login dialog page will be displayed. Enter the password, and then click the “Submit”...
  • Page 35: Hom E Page

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 4 .2 H om e Pa ge The Home link connects to the main page, which contains two parts. The first part of this page provides basic information about the tGW-700 hardware and software.
  • Page 36: Netw Ork Setti N G

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 4 .3 N e t w or k Se t t in g 4 .3 .1 N e t w or k a n d M isce lla n e ou s Se t t in gs Check the model name and the software information.
  • Page 37 ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru Item Descriptions: Item Description Static IP: If you don’t have a DHCP server in your network, you can configure the network settings manually. Please refer to the Section Manually Configuration 4.3.2.1 Addr e ss Type...
  • Page 38 ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru Network settings can be configured using either dynamic configuration or manually configuration, as per the following instructions: 4 .3 .2 .1 M a n u a l Con figu r a t ion When using manual configuration, you have to assign all the network settings in the following manner: Step 1: Select “Static IP”...
  • Page 39: General Configurat Ion Set T Ings

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 4 .3 .3 Ge n e r a l Con figu r a t ion Se t t in gs The General Configuration Settings provides functions allowing items such as the Alias Name, System Timeout value, and Auto-logout value to be configured.
  • Page 40: Rest Ore Fact Ory Default S

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 4 .3 .4 Re st or e Fa ct or y D e fa u lt s To reset the settings to their factory default, follow these steps: Step 1: Click the “Restore Defaults”...
  • Page 41: Seri Al Port Setti N Gs

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 4 .4 Se r ia l Por t Se t t in gs 4 .4 .1 Por t 1 Se t t in gs Check the tGW-700 hardware and software information. 4 .4 .2 Por t Se t t in gs The port settings provide the following functions: t GW - 7 0 0 Se r ie s Use r M a n ua l, Ve r sion 1 .6 , Ju l.
  • Page 42: Pair- Connect Ion Set T Ings

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru Item Descriptions: Item Description Default Ba u d Ra t e ( bps) Sets the Bard Rate for the COM ports. 115200 D a t a Size ( bit s) Sets the Data Size for the COM ports.
  • Page 43: C H An Ge Passw Ord

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 4 .5 Cha nge Pa ssw or d Item Descriptions: Item Description Cu r r e n t pa ssw or d Enter the old password (default is admin) Enter the new password N e w pa ssw or d Confir m ne w pa ssw or d...
  • Page 44: Typi Cal Appli Cati On S For Th E Tgw - 7 0 0

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru Typica l Applica t ion s for t h e t GW - 7 0 0 5 .1 M odbus Ga t e w a y The tGW-700 module is a Modbus TCP/UDP to RTU/ASCII gateway that enables a Modbus TCP/UDP host to communicate with serial Modbus RTU/ASCII devices through an Ethernet network, and eliminates the cable length limitation of legacy serial communication devices.
  • Page 45: Pai R - Con N Ecti On Appli Cati On S

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 5 .2 Pa ir - Con n e ct ion Applica t ion s The tGW-700 device servers can be used to create a pair-connection application (as well as serial-bridge or serial-tunnel), and then route data between two serial devices via TCP/IP, which is useful when connecting mainframe computers,...
  • Page 46: Step 1 : Con N Ecti N G To A N Etw Ork , Pc An D Pow Er

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru St e p 1 : Con n e ct in g t o a n e t w or k , PC a n d Pow e r Confirm that the tGW-700 modules are functioning correctly.
  • Page 47: Step 2 : Con Fi Guri N G Eth Ern Et Setti N Gs

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru St e p 2 : Con figu r in g Et h e r n e t Se t t in gs Contact your Network Administrator to obtain a correct and functioning network configuration (such as IP/Mask/Gateway details) for tGW-700 modules.
  • Page 48 ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 3. Click the “Port1” link to enter the settings page. Figur e 5 - 2 4. Select the appropriate Baud Rate, Data Format and Modbus Protocol settings from the relevant drop down options, for example “115200”...
  • Page 49: Step 4 : Con Fi Guri N G Pai R - Con N Ecti On On Tgw - 7 0 0 # 2 Web Server

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru St e p 4 : Con figu r in g Pa ir - Con n e ct ion on t GW - 7 0 0 # 2 W e b se r ve r 1.
  • Page 50 ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 3. Click on the “Client tools” >> “Modbus/RTU Client”. 3. Select the COM port number and settings and then click “Open” button. t GW - 7 0 0 Se r ie s Use r M a n ua l, Ve r sion 1 .6 , Ju l. 2 0 1 1...
  • Page 51 ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 4. Refer to the field "Protocol Description" at the top right of the program. You can send a request command and confirm the response is correct. (Ex: If the remote Modbus device ID = 1, you send “1 2 0 0 0 4” for reading D/I value, you may receive response “1 2 1 0 A1 88”) (“A1 88”...
  • Page 52: Appen D I X: Glossary

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru Appe n dix : Glossa r y 1 . ARP ( Addr e ss Re solu t ion Pr ot ocol) Consider two machines A and B that share a physical network. Each has an assigned IP address IP and IP , and a MAC address, MAC...
  • Page 53: Eth Ern Et

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 3 . Et h e r n e t The term Ethernet generally refers to a standard published in 1982 by Digital Equipment Corp., Intel Corp. and Xerox Corp. Ethernet is the most popular physical layer local area network (LAN) technology today.
  • Page 54: M Ac ( Med I A Access Con Trol ) Ad D Ress

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 9 . M AC ( M e dia Acce ss Con t r ol) a ddr e ss To allow a computer to determine which packets are meant for it, each computer attached to an Ethernet network is assigned a 48-bit integer known as its MAC address (also called an Ethernet address, hardware address or physical address).
  • Page 55: 4 . Subn Et Mask

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 1 4 . Su bn e t M a sk The Subnet mask is often simply called the mask. Given its own IP address and its subnet mask, a host can determine if a TCP/IP packet is destined for a host that is (1) on its own subnet, or (2) on a different network.
  • Page 56: I E

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru Appe n dix : FAQ Appe n dix : FAQ 1. How t o avoid a browser access error t hat causes a blank page t o be 1.
  • Page 57 ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru St e p 3 : Select the “Every visit to the page” option and then click the “OK” button in both the Settings dialog and the Internet Options dialog. St e p 4 : Click the “Refresh”...
  • Page 58: Or A Fi Rew All

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 2. How t o access a rem ot e t GW- 700 t hat is locat ed placed behind an NAT or a firewall. remote site must have an NAT server (or a router supports NAT).
  • Page 59: Publi C ) I N Tern Et Con N Ecti On

    3. Why does t he t GW- 700 series m odule fail on a ( public) I nt ernet connect ion? The default IP address of the tGW-700 series module is 192.168.255.1, which can be only used on a private Internet connection. A private network packet will not be routed via a (public) Internet connection, which is the reason why the tGW-700 series module fails on the Internet.
  • Page 60 ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru However, tGW-700 series modules are to be operated on the Internet using a legal public IP address. This address can be obtained from your ISP or network administrator.
  • Page 61: Seri Es M Od Ule

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 4. Why cannot com put er ping or search t he t GW- 700 series m odule? The computer can make a communication with the module through some specific ports. Please confirm with your network administrator that UDP Port 7, Port 57188 and Port 54321 can’t be denying by network device.

Table of Contents