Annex
Problem
Possible causes
No picture transmis-
Defective camera.
sion to remote station.
Faulty cable connection.
No audio transmission
Defective hardware.
to outstation.
Faulty cable connection.
Faulty configuration.
Audio voice connection is
occupied by another receiver.
VideoJet
does not
Alarm input not selected.
report an alarm.
No alarm action selected.
Not possible control
Cable connection between the
PTZ cameras or other
RS232 interfaces and the con-
devices.
nected device is incorrect.
The interface parameters con-
flict with the other devices con-
nected.
VideoJet
is not
Voltage failure while the
ready for operation
update file is being pro-
after firmware upload.
grammed.
72
Suggested remedy
Connect local monitor and check
camera function.
Check all leads, plugs, contacts and
connections.
Check perfect functioning of all audio
devices connected.
Check all leads, plugs, contacts and
connections.
Check configuration of audio settings
(interface, audio level and coding
mode).
Wait until the connection is free and
dial again.
Select alarm input on configuration
page alarm settings.
Select alarm action on configuration
page alarm settings. If necessary
change IP address and e-mail address.
Check all cable connections and
ensure all plugs are properly plugged
in.
Make sure the settings of the devices
involved agree with each other.
Replace the device and have it
checked by VCS.