Configuration with web browser
Set the sensitivity by moving to the slide controller with the mouse
key depressed to the desired position.
Click on OK to terminate the settings and to close the window.
Alarm input 1 ... 4:
The external sensors connected to the alarm inputs are monitored.
If a sensor is tripped, an alarm is triggered.
Select On to activate the alarm triggering via external sensors.
Otherwise select Off. You can specify for the alarm input whether
the alarm is triggered by the voltage level active high or active
low.
Name:
You can type a text in the text box, which is displayed on the screen
in case of an alarm.
Alarm input 5 (Master):
It is possible to use the alarm input 5 as master alarm, for example
if a key switch is used for making the system alert. If this option is
activated, the alarm input 5 must be active in order to enable all
other alarms.
Camera follows alarm input:
When an alarm is triggered, the
automatically to the input of the corresponding camera. Select On
if the image of the corresponding camera is to be displayed in the
event of an alarm, or Off if the current camera selection is to be
retained.
46
VideoJet 400 can switch over
VideoJet 400