Ametek LANDSCAN LSP-HD Installation Overview
Ametek LANDSCAN LSP-HD Installation Overview

Ametek LANDSCAN LSP-HD Installation Overview

Infrared linescanners
Table of Contents

Advertisement

LANDSCAN LSP-HD
SYSTEM INSTALLATION OVERVIEW
PUBLICATION N
811372
O
LANGUAGE: ENGLISH
Landscan LSP-HD Infrared Linescanners
i
Q U A L I T Y C U S T O M E R S O L U T I O N S

Advertisement

Table of Contents
loading

Summary of Contents for Ametek LANDSCAN LSP-HD

  • Page 1 LANDSCAN LSP-HD SYSTEM INSTALLATION OVERVIEW PUBLICATION N 811372 LANGUAGE: ENGLISH Landscan LSP-HD Infrared Linescanners Q U A L I T Y C U S T O M E R S O L U T I O N S...
  • Page 2 IMPORTANT INFORMATION - PLEASE READ Health and Safety Information Read all of the instructions in this booklet - including all the WARNINGS and CAUTIONS - before using this product. If there is any instruction which you do not understand, DO NOT USE THE PRODUCT.
  • Page 3 Web: www.landinst.com For further details on all AMETEK Land offices, distributors and representatives, please visit our websites. Return of Damaged Goods IMPORTANT If any item has been damaged in transit, this should be reported to the carrier and to the supplier immediately.
  • Page 4 Landscan LSP-HD Infrared Linescanning System Blank Installation Overview...
  • Page 5: Table Of Contents

    Infrared Linescanning System Landscan LSP-HD Contents Introduction About this Guide System Installation Sequence Typical System Configurations 2.1 Basic Single Landscan Configuration with Processor Configuration Software for TCP/IP communication 2.2 Basic Single Landscan Configuration with Processor Configuration Software and LSP-HD IO Processor 2.3 Basic Single Landscan Configuration with WCA Software 2.4 Basic Single Landscan Configuration with WCA Software and LSP-HD IO Processor 2.5 Two Scanner Landscan Configuration with WCA Software and one LSP-HD IO Processor 2.6 Two Scanner Landscan Configuration with WCA Software and two LSP-HD IO Processors 2.7 Multiple Scanner Landscan Configuration with WCA Software and one LSP-HD IO Processor 2-10 2.8 Multiple Scanner Landscan Configuration with WCA Server and Client Software and one LSP-HD IO Processor 2-12 2.9 Multiple Scanner Landscan Configuration with WCA Server and...
  • Page 6: Introduction

    INTRODUCTION...
  • Page 7: About This Guide

    Infrared Linescanning System Landscan LSP-HD Introduction 1.1 About this Guide This document provides an overview of the components available in a Landscan LSP-HD Infrared Linescanning System and is intended as a guide to the installation and commissioning procedure. Note that, due to the variety of system configurations available, there is no definitive ‘standard’ installation and commissioning process. However, this document provides an overview of the typical steps required to complete installation and commissioning. A description of the most common configurations available, from basic single scanner systems to multiple Scanner systems with I/O processors, is given in Section 2. Read this document thoroughly prior to installing your system, referring also to the user documentation provided with the components of your LSP-HD system. 1.2 System Installation Sequence A typical installation and commissioning sequence is outlined below: Install the Mounting and verify that the Scanner is aligned correctly on the target i.e. there is nothing in the field of view which obscures the sighting: • Make sure that there is no framework or similar in the field of view; • In order to avoid reflections, install the mounting such that the scanner does not look onto rollers; • If heat shields are installed the cutout must give sufficient space for the scan angle (Maximum scan angle is 80°);...
  • Page 8 Landscan LSP-HD Infrared Linescanning System 10) Setup the communication to the Scanner and Beckhoff IO: All Scanners delivered from AMETEK Land are shipped with the same default • IP Address: 10.1.10.100; • All Beckhoff IO units have a default IP Address: 10.1.10.110; • Therefore, if you are setting up a multiple scanner system, the scanners must be connected to the network in sequence. You will need to change the IP address* of the first scanner connected to avoid any address conflict in the network. It is recommended to change the IP for the first scanner to 10.1.10.101, and the second scanner to 10.1.10.102, and so on. This also avoids any address conflict problems if a spare or repaired scanner with a default IP address has to be integrated into an existing system. • If you have multiple Beckhoff IO units, you will also need to change their IP addresses in a similar manner. i.e. set the first IP address to 10.1.10.111 etc. Instructions on how to set the IP address of each component in your LSP-HD system are given in Section 7.2.4 of this Guide. 1 - 2 Installation Overview...
  • Page 9: Typical System Configurations

    TYPICAL SYSTEM CONFIGURATIONS...
  • Page 10 Landscan LSP-HD Infrared Linescanning System Blank Installation Overview...
  • Page 11: Basic Single Landscan Configuration With Processor Configuration Software For Tcp/Ip Communication

    Infrared Linescanning System Landscan LSP-HD Typical System Configurations This section gives an overview of the components and options available in typical configurations of a Landscan LSP-HD system. Further information on each component is given in subsequent sections of this guide. Identify which configuration matches your system and refer to the relevant sections of this guide for installation and commissioning information. 2.1 Basic Single Landscan Configuration with Processor Configuration Software for TCP/IP communication Customer’s RJ45 Ethernet cable Customer’s PC Processor Configuration Software supplied with LSP-HD Item Component Option (Illustrated options shown in Bold text) Land Part Nº...
  • Page 12: Basic Single Landscan Configuration With Processor Configuration Software And Lsp-Hd Io Processor

    Landscan LSP-HD Infrared Linescanning System 2.2 Basic Single Landscan Configuration with Processor Configuration Software and LSP-HD IO Processor Customer’s RJ45 Ethernet cables Optional PC for Configuration / Data Display Item Component Option (Illustrated options shown in Bold text) Land Part Nº Scanner LSP-HD xx 80xxxx Mounting Basic Mounting Plate 031.520 • Optional Right Angle Bracket 031.438...
  • Page 13: Basic Single Landscan Configuration With Wca Software

    Infrared Linescanning System Landscan LSP-HD 2.3 Basic Single Landscan Configuration with WCA Software Item Component Option (Illustrated options shown in Bold text) Land Part Nº Scanner LSP-HD xx 80xxxx Mounting Basic Mounting Plate 031.520 • Optional Right Angle Bracket (Item 2a) 031.438 Water Cooled, Air Purged Base Plate 031.496 • Optional Right Angle Bracket (Item2a)
  • Page 14: Basic Single Landscan Configuration With Wca Software And Lsp-Hd Io Processor

    Landscan LSP-HD Infrared Linescanning System 2.4 Basic Single Landscan Configuration with WCA Software and LSP-HD IO Processor Customer’s RJ45 Ethernet cables 2 - 4 Installation Overview...
  • Page 15 Infrared Linescanning System Landscan LSP-HD Item Component Option Land Part Nº Scanner LSP-HD xx 80xxxx Mounting Basic Mounting Plate 031.520 • Optional Right Angle Bracket 031.438 Water Cooled, Air Purged Base Plate 031.496 • Optional Right Angle Bracket 031.438 Enhanced Water Cooled Mounting System 800095 Light Industrial Housing (with Air Purging/Water Cooling) 802664 Light Industrial Housing (with non-reflective heat shield) 806578 Heavy Industrial Housing (with Air Purging/Water 802665 Cooling) Water Cooled Plate (Sealed to Process) 805154...
  • Page 16: Two Scanner Landscan Configuration With Wca Software And One Lsp-Hd Io Processor

    Landscan LSP-HD Infrared Linescanning System 2.5 Two Scanner Landscan Configuration with WCA Software and one LSP-HD IO Processor 2 - 6 Installation Overview...
  • Page 17 Infrared Linescanning System Landscan LSP-HD Item Component Option Land Part Nº Scanner LSP-HD xx 80xxxx Basic Mounting Plate 031.520 • Optional Right Angle Bracket 031.438 Water Cooled, Air Purged Base Plate 031.496 • Optional Right Angle Bracket 031.438 Mounting Enhanced Water Cooled Mounting System 800095 Light Industrial Housing (with Air Purging/Water Cooling) 802664 Light Industrial Housing (with non-reflective heat shield) 806578 Mounting Heavy Industrial Housing (with Air Purging/Water...
  • Page 18: Two Scanner Landscan Configuration With Wca Software And Two Lsp-Hd Io Processors

    Landscan LSP-HD Infrared Linescanning System 2.6 Two Scanner Landscan Configuration with WCA Software and two LSP-HD IO Processors 2 - 8 Installation Overview...
  • Page 19 Infrared Linescanning System Landscan LSP-HD Item Component Option Land Part Nº Scanner 80xxxx LSP-HD xx Mounting Basic Mounting Plate 031.520 • Optional Right Angle Bracket 031.438 Mounting Water Cooled, Air Purged Base Plate 031.496 • Optional Right Angle Bracket 031.438 Enhanced Water Cooled Mounting System 800095 Light Industrial Housing (with Air Purging/Water Cooling) 802664 Light Industrial Housing (with non-reflective heat shield) 806578 Heavy Industrial Housing (with Air Purging/Water Cooling) 802665 Water Cooled Plate (Sealed to Process)
  • Page 20: Multiple Scanner Landscan Configuration With Wca Software And One Lsp-Hd Io Processor

    Landscan LSP-HD Infrared Linescanning System 2.7 Multiple Scanner Landscan Configuration with WCA Software and one LSP-HD IO Processor 2 - 10 Installation Overview...
  • Page 21 Infrared Linescanning System Landscan LSP-HD Item Component Option Land Part Nº Scanner LSP-HD xx 80xxxx Mounting Basic Mounting Plate 031.520 • Optional Right Angle Bracket 031.438 Mounting Water Cooled, Air Purged Base Plate 031.496 • Optional Right Angle Bracket 031.438 Mounting Enhanced Water Cooled Mounting System 800095 Light Industrial Housing (with Air Purging/Water Cooling)
  • Page 22: Multiple Scanner Landscan Configuration With Wca Server And Client Software And One Lsp-Hd Io Processor

    Landscan LSP-HD Infrared Linescanning System 2.8 Multiple Scanner Landscan Configuration with WCA Server and Client Software and one LSP-HD IO Processor 2 - 12 Installation Overview...
  • Page 23 Infrared Linescanning System Landscan LSP-HD Item Component Option Land Part Nº Scanner LSP-HD xx 80xxxx Mounting Basic Mounting Plate 031.520 • Optional Right Angle Bracket 031.438 Mounting Water Cooled, Air Purged Base Plate 031.496 • Optional Right Angle Bracket 031.438 Mounting Enhanced Water Cooled Mounting System 800095 Light Industrial Housing (with Air Purging/Water Cooling)
  • Page 24: Multiple Scanner Landscan Configuration With Wca Server And Client Software And Multiple Lsp-Hd Io Processors

    Landscan LSP-HD Infrared Linescanning System 2.9 Multiple Scanner Landscan Configuration with WCA Server and Client Software and multiple LSP-HD IO Processors 2 - 14 Installation Overview...
  • Page 25 Infrared Linescanning System Landscan LSP-HD Item Component Option Land Part Nº Scanner LSP-HD xx 80xxxx Mounting Basic Mounting Plate 031.520 • Optional Right Angle Bracket 031.438 Mounting Water Cooled, Air Purged Base Plate 031.496 • Optional Right Angle Bracket 031.438 Mounting Enhanced Water Cooled Mounting System 800095 Light Industrial Housing (with Air Purging/Water Cooling)
  • Page 26: Mounting Accessories

    MOUNTING ACCESSORIES...
  • Page 27 Infrared Linescanning System Landscan LSP-HD Mounting Accessories This section of the guide contains installation information for the following Mounting Accessories: • Basic Mounting Plate (031.520) • Optional Right Angle Mounting Plate (031.438) • Water Cooled, Air Purged Base Plate (031.496) • Optional Right Angle Mounting Plate (031.438) • E nhanced Water Cooled Mounting System (800095) • L ight Industrial Housing (with Air Purging/Water Cooling) (802664) • H eavy Industrial Housing (with Air Purging/Water Cooling) (802665) Installation Overview 3 - 1...
  • Page 28: Basic Mounting Plate - Part Nº 031.520

    Landscan LSP-HD Infrared Linescanning System 3.1 Basic Mounting Plate - Part Nº 031.520 The Basic Mounting Plate is used in applications where an LSP-HD Linescanner head is to be installed in light industrial environments where the ambient temperatures is within the recommended operating range of the instrument and the atmosphere is relatively free from dust and airborne particles. The basic base plate provides a quick release mounting arrangement for the scanner, making realignment a simple and easy operation. Specifications Maximum Ambient Temperature 60 °C / 140 °F Weight 1.2 kg / 2.6 lb Dimensions (L x W x D) 276 x 176 x 52.5 mm / 10.87 x 6.93 x 2.07 in Mounting Holes Ø 8.5 mm / 0.34 in to accept M8 screws All dimensions in mm/in Dimensions 22.5/0.89 276/10.87 240/9.45 Hole Ø8.5/0.34 to accept M8 screws...
  • Page 29: Water Cooled, Air Purged Base Plate - Part Nº 031.496

    Infrared Linescanning System Landscan LSP-HD 3.2 Water Cooled, Air Purged Base Plate - Part Nº 031.496 The Water Cooled, Air Purged Base Plate is used in applications where an LSP-HD Linescanner is to be installed into environments where the ambient temperatures are in the range of 60 to 100 °C / 140 to 212 °F. It is ideally suited to general industrial applications. The air purge facility should be utilised where the operating environment is dusty and airborne particles could contaminate the scanner viewing window. The plate provides a quick release mounting arrangement for the scanner, making realignment a simple and easy operation. Specifications Maximum Ambient Temperature 100 °C / 212 °F Cooling Water Requirements 1.5 to 2 litre per min / 0.4 to 0.53 US gal per min @ 30 °C / 86 °F Maximum Water Pressure 5.88 Bar / 85 PSI Cooling Water Connection ¼ in BSP for 9.5 mm / 3/8 in bore water hose Air Purge Requirements 300 litre per min / 12.36 cu ft per min...
  • Page 30: Right Angle Mounting Plate - Part Nº 031.438

    Landscan LSP-HD Infrared Linescanning System 3.3 Right Angle Mounting Plate - Part Nº 031.438 The right angle mounting plate is a simple design intended for basic LSP-HD Linescanner Head mounting. It is designed for wall mounting and is pre-drilled to accept either the Basic Mounting Plate (031.520) or the Water Cooled, Air Purged Base Plate (031.496). All fixings are supplied with the plate. All dimensions in mm/in Dimensions 240/9.45 Stainless Steel All dimensions in mm/in Scanner mounting face 222/8.74 Hole Ø8.5/0.34 to accept M8 screws 3 - 4 Installation Overview...
  • Page 31: Enhanced Water Cooled Mounting System - Part Nº 800095

    Infrared Linescanning System Landscan LSP-HD 3.4 Enhanced Water Cooled Mounting System - Part Nº 800095 The Water Cooled, Air Purged Base Plate is used in applications where an LSP-HD Linescanner is to be installed into environments where the ambient temperatures are in the range of 60 to 120 °C / 140 to 248 °F.
  • Page 32: Light Industrial Housing - Part Nº 802664

    Landscan LSP-HD Infrared Linescanning System 3.5 Light Industrial Housing - Part Nº 802664 The Light Industrial Housing is used in applications where an LSP-HD scanner needs to be enclosed for additional protection due to airborne particulates. It can be installed into environments where the ambient temperatures are up to 150°C / 302°F.
  • Page 33: Heavy Industrial Housing - Part Nº 802665

    Infrared Linescanning System Landscan LSP-HD 3.6 Heavy Industrial Housing - Part Nº 802665 The Heavy Industrial Housing is used in applications where an LSP-HD scanner needs to be enclosed for additional protection due to airborne particulates or for outdoor operation. It can be installed into environments where the ambient temperatures are up to 150°C / 302°F. The air purge facility should be utilised where the operating environment is dusty and airborne particles could contaminate the scanner viewing window. A quick release mounting arrangement is included for the scanner, making realignment a simple and easy operation. Specifications Maximum Ambient Temperature 150 °C / 302 °F...
  • Page 34: Blowers

    BLOWERS...
  • Page 35 Infrared Linescanning System Landscan LSP-HD Blowers The Plate Mounted Blower unit provides air to the LSP-HD. Each specific application may require a controlled air supply. Optical air purging may be required in order to maintain a clear sighting window. Each blower can support up to two scanners. Specifications Option 1 Option 2 Option 3 Power Supply 230 V a.c. 110 V a.c. 220 v a.c. Frequency 50 Hz 60 Hz 60 Hz Power Consumption 400 W 500 W 500 W Circuit Breaker 10 A 16 A 10 A (Type C) Operating -20 to 50 °C/-4 to 122 °F (-40 to 50 °C/-40 to 122 °F with optional air Temperature:...
  • Page 36: Power Supplies

    POWER SUPPLIES...
  • Page 37: Lsp-Hd Desktop Power Supply - Part Nº 805024

    Infrared Linescanning System Landscan LSP-HD Power Supplies This section of the guide contains installation information for the following Power Supplies: • LSP-HD Desktop Power Supply (805024) • LSP-HD Industrial Power Supply on a DIN Rail (807105) • L SP-HD Industrial Power Supply in a Terminal Box (805037) 5.1 LSP-HD Desktop Power Supply - Part Nº 805024 The Desktop Power Supply is an unsealed power supply for use in clean environments to provide power for the LSP-HD. Note: To connect the LSP-HD power and signal cable to the Desktop Power Supply (Part Nº 805024) you will need to use the M12 to RJ45 Cable (0.5 m) Part Nº 805023. Specifications Input Power Supply 100 to 240 V a.c. Instrument Connection 1 x RJ45 termination Downstream Connections 1 x RJ45 termination Supplied with:...
  • Page 38: Lsp-Hd Industrial Power Supply On A Din Rail - Part Nº 807105

    Landscan LSP-HD Infrared Linescanning System 5.2 LSP-HD Industrial Power Supply on a DIN Rail - Part Nº 807105 This is a DIN rail mounted power supply unit for fitting inside cabinets. Specifications Input Power Supply 100 to 240 V a.c. LSP-HD Connection 1 x RJ45 termination Downstream Connections 1 x Multi-Mode Fibre Optic SC 4 x RJ45 Terminations Maximum Ambient Temperature 45 °C / 113 °F Dimensions (h x w x d) 170 x 200 x 200 mm / 6.8 x 7.9 x 7.9 in Note: To comply with safety regulations the system must be mounted inside an enclosure 5 - 2...
  • Page 39: Lsp-Hd Industrial Power Supply In A Terminal Box - Part Nº 805037

    Infrared Linescanning System Landscan LSP-HD 5.3 LSP-HD Industrial Power Supply in a Terminal Box - Part Nº 805037 This is a terminal box which allows connection of the incoming LSP-HD connection cable via an M12 industrial Ethernet port, incoming mains power and the downstream data connection via either CAT 5 / 6 cable or multi-mode fibre optic. Note: This unit is for indoor use only. Specifications Input Power Supply 100 to 240 V a.c. Instrument Connection M12 4 pin D-Coded Industrial Ethernet Socket Downstream Connections 1 x Multi-Mode Fibre Optic SC 4 x RJ45 Terminations...
  • Page 40: Cables

    CABLES...
  • Page 41 Infrared Linescanning System Landscan LSP-HD Cables Connection cables between the LSP-HD scanner and the LSP-HD Power Supply unit are pre-terminated with M12 industrial Ethernet connectors. This single cable provides both data and Power-over-Ethernet connections. Specifications LSP-HD 15m LSP-HD 30m LSP-HD 15m Low Temperature Low Temperature High Temperature Part Number 805038 807087 804977 Length 15 m / 49 ft 30 m / 98 ft 15 m / 49 ft Maximum Ambient 80 °C / 176 °F 80 °C / 176 °F 200 °C / 390 °F Temperature Note: To connect any of the above cables to the Desktop Power Supply (Part Nº 805024) you will need the M12 to RJ45 Cable (0.5 m) Part Nº 805023.
  • Page 42: Software Setup

    SOFTWARE SETUP...
  • Page 43: Software Registration

    Infrared Linescanning System Landscan LSP-HD Software Setup The installation of the Data Server requires a licence key. To obtain the key the following information is required: • Copy Control Version • Product Name • Serial Number • Update Number From the Landscan directory run Register.exe to open the Change or Remove Registration dialog. This registration information is usually available to AMETEK Land engineers during the commissioning process. If you need to obtain your license...
  • Page 44: Basic Software Setup

    Landscan LSP-HD Infrared Linescanning System 7.2 Basic Software Setup This section gives an overview about the basic system settings to setup the Landscan software for visualisation, data processing and data storage • Double click on the Start Landscan desktop icon to start the Software: 7.2.1 Start Screen After initial setup, the blank start screen is shown. 7.2.2 Basic Configuration From the Configure menu, select System to enter the Basic Configuration dialog: 7 - 2 Installation Overview...
  • Page 45 Infrared Linescanning System Landscan LSP-HD 7.2.3 Basic Configuration – Process tab Select the Units of Temperature, Units of Distance, Units of Product Width and Units of Longitudunal Measurement for display setup and orientation. Define names for left and right side of the process to be monitored. Define the number of scanners connected to the software. A change here requires a reboot of the software. Installation Overview 7 - 3...
  • Page 46 Landscan LSP-HD Infrared Linescanning System Orientation Naming To interpret the scan profile produced by the Scanner, the scan direction must be known. This is indicated by an embossed arrow cast into the top of the Scanner. The Scanner always scans from the left to the right, where the arrowhead indicates the right side of the scan. The Profile display indicates the Left side with (-) and the Right side with (+). 7 - 4 Installation Overview...
  • Page 47 Infrared Linescanning System Landscan LSP-HD 7.2.4 Basic Configuration – Equipment tab Allocate the Network IP Address of the connected Scanner and IO Processor. Access the IO Configuration of the connected IO processor. Allocate the Network IP Address of the connected Scanner and IO Processor. Access the IO Configuration of the connected IO processor. Installation Overview 7 - 5...
  • Page 48 Landscan LSP-HD Infrared Linescanning System Apply the necessary IP Address change and confirm with OK. Double click on the highlighted line to see the new IP Address in the Network IP Address box. Deactivate Maintenance to activate the Station. The same action can be taken in the IO IP Address box to perform an IP Address change on the Beckhoff IO Processor. 7 - 6 Installation Overview...
  • Page 49 Infrared Linescanning System Landscan LSP-HD To allocate the IOs, select the IO Configuration option. Click the Login button. Double click in the Device Communication Partner IP Address and select the Scanner. 10) Tick the Enable Login checkbox. 11) Enter the required number of IOs in Channels in Use by this partner. 12) Confirm any change with Apply to IO System, then Logout, then OK. The Beckhoff IO Processor is now setup for communication with the Scanner. Installation Overview 7 - 7...
  • Page 50 Landscan LSP-HD Infrared Linescanning System 7.2.5 Basic Configuration - Icons A successfully established communication between WCA Software, Scanner and Beckhoff IO is indicated by the colour of the station icons in the status bar: Connection established No connection between PC and Scanner No connection between Scanner and Beckhoff IO Station in Maintenance (Basic Configuration : Equipment tab) Scanner in Maintenance (Basic Configuration : Line Scanner tab) 7 - 8 Installation Overview...
  • Page 51 Infrared Linescanning System Landscan LSP-HD 7.2.6 Basic Configuration – Product tab Select Date and Time for the Product Name. Select Automatic (Percentage of Peak) and a value of 40% for the Hot Edge Detection. Set the appropriate value for Emissivity. Select Hot Edges for Product Determination to determine a product once the hot edges are detected.
  • Page 52 Landscan LSP-HD Infrared Linescanning System 7.2.7 Basic Configuration – Processor Input tab This tab shows the active Analogue Inputs and Digital Inputs of a connected Beckhoff IO Processor. If an analogue speed signal is used, select the Process Speed Function, the mA Range (either0 or 4 to 20mA) and the relevant Scale. This example shows 4 to 20mA for 0 to 8000 mm/sec. A digital input can be activated to trigger the product determination by selecting the Process Input function. This requires the activation of Digital Input at LPU/LSC and allocation of the input channel on the Product tab. 7 - 10...
  • Page 53 Infrared Linescanning System Landscan LSP-HD 7.2.8 Basic Configuration – Line Scanner tab Select the required Scanner Speed in a range between 10 and 150 Hz. Enter the Distance from product (this is the distance between Scanner Window and product surface). The Scan Angle can be altered between 40 and 80 degrees and will be shown in the relevant displays. Select the Enable Internal Ambient Temperature Sensor option to display the ambient temperature of the Scanner.
  • Page 54: Data Processing

    Landscan LSP-HD Infrared Linescanning System 7.3 Data Processing 7.3.1 Control Zone Processing From the Data Processing menu, select Control Processing to apply Control Zones. Double-click into the line of each Zone to display the dialog, which allows you to set the relevant Zone parameters: Units: either % or mm • • Reference: Start, Centre or End of Scanline • Size: Start and End Position Tracking: within Hot Edges or fixed position • • Processing: e.g. Peak, Min etc. 7 - 12 Installation Overview...
  • Page 55 Infrared Linescanning System Landscan LSP-HD 7.3.2 Data Processing - Zone Alarms Zone Alarms can be applied to each individual Control Zone. Select the required Level. Select the required Type, either High or Low. Installation Overview 7 - 13...
  • Page 56 Landscan LSP-HD Infrared Linescanning System 7.3.3 Data Processing - Analogue Output Processing To allocate the set Control Zones to an analogue Output, the relevant Channels have to be activated: Channel On. Select Zone Value as the Function for the selected Channel. The Function Parameter: 1, 2, 3 etc. indicate the reference to the individual Control Zone. The Range can be selected as either 0 or 4 to 20mA output signal. 7 - 14 Installation Overview...
  • Page 57 Infrared Linescanning System Landscan LSP-HD 7.3.4 Data Processing - Digital Output Processing • Digital Outputs are commonly used for Zone Alarms, either High/Low Alarms or to give a warning signal if the Scanner Ambient temperatures exceed the specified limits. The reference for the Zone Alarm is the Function Parameter which indicates the • allocated Control Zone. • If Ambient Hi Warning is selected, the relay trips at 65 °C: the Ambient Hi Alarm trips at 70 °C. Installation Overview...
  • Page 58: Display

    Landscan LSP-HD Infrared Linescanning System 7.4 Display 7.4.1 Display - New Display From the Display menu, select New Display. From the Select data source, select the Measurement Station and the option Real Time Scanner. This will provide a display which shows continuously the live data generated by the Scanner. Once the data source (Measurement Station) is set, the Display Type can be selected. The most common display types are Profile and Map. 7 - 16...
  • Page 59 Infrared Linescanning System Landscan LSP-HD 7.4.2 Display - Profile The Profile Display is a simple line plot of the scan line of temperature. Profile Display Profile Display showing positions of Control Zones: Right mouse click into the Display and select Show Control Zones. Installation Overview 7 - 17...
  • Page 60 Landscan LSP-HD Infrared Linescanning System 7.4.3 Display - Map The Map displays the temperature samples in a scan as points of colour arranged in a vertical line. A scale on the side of the map defines the temperature range represented by each individual colour. 7 - 18 Installation Overview...
  • Page 61: Storage Management

    Infrared Linescanning System Landscan LSP-HD 7.5 Storage Management 7.5.1 General tab From the Storage menu, select Management to activate data storage and database settings. On the General tab select the required Database size to define the limit of the Database When Delete the oldest products is selected, the oldest product file will be deleted from the Database when the set limit is reached. Select a Storage Location. It is recommended to set the Database on a different drive or a partition. Installation Overview 7 - 19...
  • Page 62 Landscan LSP-HD Infrared Linescanning System 7.5.2 Station tab On the Station tab, select the Storage Mode. If Store Products is selected, products will be stored automatically as soon as detected by the Scanner. In Storage Data Reduction a choice of options is available to reduce the size of product files, e.g. • Product Reduction • Line Reduction • Sample Reduction Activate Storage Enabled for each Station. Storage will start as soon as System Storage is activated on the General tab. 7 - 20 Installation Overview...
  • Page 63 Infrared Linescanning System Landscan LSP-HD 7.5.3 LandscanDatabase On the Station tab, select the Storage Mode. If Store Products is selected, products will be stored automatically as soon as detected by the Scanner. In Storage Data Reduction a choice of options is available to reduce the size of product files, e.g. • Product Reduction • Line Reduction • Sample Reduction Activate Storage Enabled for each Station. Storage will start as soon as System Storage is activated on the General tab. Installation Overview 7 - 21...
  • Page 64: Diagnostics

    Landscan LSP-HD Infrared Linescanning System 7.6 Diagnostics 7.6.1 Scanner From the Diagnostics menu, select Scanner to display the Scanner Status window. The Scanner Status window displays the actual scan speed and the ambient temperature of the Scanner. 7.6.2 LPU/LSC –Internal Event Log The Internal Event Log tab in the LPU/LSC Diagnostics window displays the Version Information of the connected LSP-HD Scanner or LSC Processor. 7 - 22 Installation Overview...
  • Page 65 Infrared Linescanning System Landscan LSP-HD 7.6.3 LPU/LSC – Test Outputs The Test Outputs tab in the LPU/LSC Diagnostics window displays a test mode facility to check analogue and digital outputs of a connected Beckhoff IO Processor. Simply activate the Override the LPU/LSC Outputs option and check the digital and analogue outputs by activating the tick boxes and moving the sliders. Installation Overview 7 - 23...
  • Page 66: Save Configuration

    Landscan LSP-HD Infrared Linescanning System 7.7 Save Configuration From the File menu, select Save Configuration. Once the setup of WCA software (with all necessary settings) has finished, select the Save Configuration option from File menu. The actual system configuration will be stored as MasterConfig.mdb in the ConfigDatabase folder of the Landscan directory. 7.8 Change Configuration From the File menu, select Change Configuration. Confirm the Replace on Restart Message with Yes. The software will reboot then and will ask you to choose the configuration database to be used. Select Use a previously saved database, the Open window will then display the configurations stored in the ConfigDatabase folder. 7 - 24...
  • Page 67: Save Lpu/Lsc Configuration

    Infrared Linescanning System Landscan LSP-HD 7.9 Save LPU/LSC Configuration From the File menu, select Save LPU/LSC Configuration. The actual Scanner Configuration will be stored as LPU2Config_1.mdb in the Workspace folder of the Landscan directory. 7.10 Change LPU/LSC Configuration From the File menu, change Save LPU/LSC Configuration. Confirm the Caution message with Yes and select the Measurement Station. From the Open dialog, select the saved configuration file from the Workspace folder and confirm with Open. Installation Overview 7 - 25...
  • Page 68: Maintenance & Service

    MAINTENANCE & SERVICE...
  • Page 69 Infrared Linescanning System Landscan LSP-HD Maintenance & Service The body of the scanner and the mountings can be cleaned by wiping with a clean cloth moistened with either water or a mild, neutral detergent. The scanner window can be cleaned by using any soft cloth along with a mild kitchen type detergent cleaner. The scanner window is sapphire and so resists scratching, acids or solvents. Hoses and pipes should be checked regularly for leaks and/or cracks. We strongly recommend to use flow meters/indicators to monitor the air and water flow. If the cleanliness of the water supply cannot be guaranteed, the a 100 ~ 150 µm particle filter should be installed in the supply feed. A by-pass should be available for when the filter has to be replaced. The recommended calibration interval for this system is 12 months.
  • Page 71 Land Instruments International Ltd • Dronfield S18 1DJ • England • Tel: +44 (0) 1246 417691 • Fax: +44 (0) 1246 410585 Email: land.enquiry@ametek.com • www.landinst.com AMETEK Land, Inc. • 150 Freeport Rd. • Pittsburgh, PA 15238 • U.S.A. • Tel: +1 (412) 826 4444 Email: irsales@ametek.com • www.ametek-land.com MARCOM0411 For a complete list of our international offices, please visit www.landinst.com...
  • Page 72 LANDSCAN LSP-HD INFRARED LINESCANNERS AMETEK Land China Service AMETEK Land India Service Land Instruments International AMETEK Land - Americas Dronfield, S18 1DJ, 150 Freeport Road, Pittsburgh, Part A, 1st Floor No. 460 Divyasree N R Enclave,Block A, North Fute Road,...

Table of Contents