Page 1
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment SERVICE CENTER REPAIRS WE BUY USED EQUIPMENT • FAST SHIPPING AND DELIVERY Experienced engineers and technicians on staff Sell your excess, underutilized, and idle used equipment at our full-service, in-house repair center We also offer credit for buy-backs and trade-ins •...
Page 2
User Guide IQS-3150 Variable Attenuator for IQS Platforms Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 3
EXFO Inc. (EXFO). Information provided by EXFO is believed to be accurate and reliable. However, no responsibility is assumed by EXFO for its use nor for any infringements of patents or other rights of third parties that may result from its use.
Contents Contents Certification Information ......................v 1 Introducing the IQS-3150 Variable Attenuator ........... 1 Models and Options .......................1 Typical Applications ........................3 Main Software Features ......................4 Conventions ..........................8 Safety Information ........................9 2 Getting Started with Your Variable Attenuator ........11 Inserting and Removing Test Modules ..................11 Starting the Variable Attenuator Application ................16...
Page 5
10 Warranty ......................85 General Information ......................85 Liability ..........................85 Exclusions ..........................86 Certification ..........................86 Service and Repairs .......................87 EXFO Service Centers Worldwide ..................88 A Technical Specifications ................89 B SCPI Command Reference ................91 Quick Reference Command Tree ...................92 Product-Specific Commands—Description ................94 Index .......................155 IQS-3150 Artisan Technology Group - Quality Instrumentation ...
Electronic test and measurement equipment is exempt from FCC part 15, subpart B compliance in the United States of America and from ICES-003 compliance in Canada. However, EXFO Inc. makes reasonable efforts to ensure compliance to the applicable standards. The limits set by these standards are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Introducing the IQS-3150 Variable Attenuator The IQS-3150 is a versatile variable attenuator. It can be used as a regular attenuator or it can be equipped with an integrated power meter, which allows you to work not only in attenuation but also in power level requirements.
Page 9
Introducing the IQS-3150 Variable Attenuator Models and Options The IQS-3150 Variable Attenuator is available in four models: Standard singlemode Standard multimode Self-adjusting singlemode (added Output Power control mode) Self-adjusting multimode (added Output Power control mode) The self-adjusting modules offer two operation modes: Attenuation and Power Output.
Introducing the IQS-3150 Variable Attenuator Typical Applications Typical Applications The IQS-3150 Variable Attenuator can be used in a number of test situations. It is ideal for manufacturing and laboratory applications: Erbium-doped-fiber amplifier (EDFA) and system characterization Component and system loss simulation ...
Introducing the IQS-3150 Variable Attenuator Main Software Features Main Software Features The dedicated software functions are very similar whether you are using a self-adjusting or standard module. The following is an overview of the main features. Control Center For the standard module, the output power value does not appear on the data display and there is no Output Power tab in the Control Center.
Page 12
Introducing the IQS-3150 Variable Attenuator Main Software Features Control Modes (Self-Adjusting Modules) With the self-adjusting modules, you can select between two control modes: Attenuation and Output Power. Control Mode Description Attenuation The instrument applies the attenuation values you have selected.
Page 13
Introducing the IQS-3150 Variable Attenuator Main Software Features Display Modes Both standard and self-adjusting modules give you a choice of three display modes: Absolute, Reference, and X+B. Attenuation Display Mode Description Absolute The displayed attenuation takes into account both the absolute value (default mode) and the offset value.
Page 14
The correction factor value is specific to the wavelength. Multiple Module Control The multimodule application is used to control and monitor several IQS-3150 variable attenuators at the same time. Variable Attenuator Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Introducing the IQS-3150 Variable Attenuator Conventions Conventions Before using the product described in this guide, you should understand the following conventions: ARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Do not proceed unless you understand and meet the required conditions.
Introducing the IQS-3150 Variable Attenuator Safety Information Safety Information Your IQS-3150 Variable Attenuator does not include laser components in itself. However, other modules or units you will use may do so. Please, make sure to follow all laser safety rules.
This will result in immediate and irreparable damage to both the module and unit. AUTION To avoid damaging your unit, use it only with modules approved by EXFO. Variable Attenuator Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 19
Retaining screw knob 3. Position the module so that its front panel is facing you and the top and bottom protruding edges are to your right. IQS-3150 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 20
Getting Started with Your Variable Attenuator Inserting and Removing Test Modules 4. Insert the protruding edges of the module into the grooves of the unit’s module slot. Protruding edges (right side of module) Retaining screw knob Retaining screw 5. Push the module all the way to the back of the slot, until the retaining screw makes contact with the unit casing.
Page 21
Retaining screw knob 2. Place your fingers underneath the module or hold it by the retaining screw knob (NOT by the connector) and pull it out. IQS-3150 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 22
Getting Started with Your Variable Attenuator Inserting and Removing Test Modules Connector Retaining screw knob AUTION Pulling out a module by a connector could seriously damage both the module and connector. Always pull out a module by the retaining screw knob. 3.
Getting Started with Your Variable Attenuator Starting the Variable Attenuator Application Starting the Variable Attenuator Application Your IQS-3150 Variable Attenuator module can be configured and controlled from its dedicated IQS Manager application. Note: For details about IQS Manager, refer to the IQS platform user guide.
Page 24
Getting Started with Your Variable Attenuator Starting the Variable Attenuator Application Press the green LED push button on the front of the corresponding module. You can also double-click its row. Note: Pressing the LED push button will only enable you to switch to the module application.
Page 25
Self-adjusting module Current attenuation (Attenuation control mode) or selected output power (Output Power control mode) Output power Standard module Current attenuation Shutter status and message area IQS-3150 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 26
Lockout: Module controlled remotely only. Module/unit status Current date and time For more information about automating or remotely controlling the IQS-3150 Variable Attenuator, refer to your platform user guide. Variable Attenuator Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Getting Started with Your Variable Attenuator Exiting the Application Exiting the Application Closing any application that is not currently being used helps freeing system memory. To close the application from the main window: Click in the top right corner of the main window. Click the Exit button located at the bottom of the function bar.
Setting Up Your Variable Attenuator The IQS-3150 comes with factory default settings; however, you can create custom settings and save them in configuration files. Basic Settings When you start the Variable Attenuator dedicated application, it opens the Instrument function tab. To start building your own test settings, click the Settings function tab.
Page 31
1. On the Settings function tab, click the Presets tab and, under Wavelength or Fine-Tuning Step, click a value in the list to select it. 2. Click the button to delete the value. IQS-3150 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 32
Setting Up Your Variable Attenuator Basic Settings Setting the B Value The B value settings are necessary for the X+B display mode. These settings apply to one or many wavelengths defined in the Wavelength list and are only enabled when using this display mode. The B value settings are available for both standard and self adjusting modules.
Page 33
1. On the Settings function tab, click the Presets tab. 2. Under B Value, in the Wavelength list, use the up/down arrows to select the wavelength for which you want to add a correction factor. IQS-3150 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 34
Setting Up Your Variable Attenuator Basic Settings 3. According to the control mode used, select the correction factor as follows: For the Attenuation mode, under Attenuation Mode, click the Correction Factor button, and enter the correction value in the box next to it.
Page 35
2. Under B Value, under Attenuation Mode, click the Input Power button. 3. In the box next to Input Power, enter the source power in dBm. 4. Click Apply. IQS-3150 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 36
Setting Up Your Variable Attenuator Basic Settings Setting the Drift Tolerance The drift tolerance setting is only available for the self-adjusting modules and is only applicable for the Power Tracking function (see Using the Power Tracking Function (Self-Adjusting Modules) on page 56). When you use the power tracking function, the internal power meter monitors the output power level and constantly adjust the attenuation to ensure that the output power does not exceed the limits set (drift...
Page 37
1. On the Settings function tab, click the Presets tab. 2. Under Output Power Mode, in the Value box, enter the tolerance value. 3. Click the button to accept the value. IQS-3150 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Setting Up Your Variable Attenuator Control Center Settings and Controls Control Center Settings and Controls Once the basic settings are entered, you can set parameters in the Control Center to create your test configuration. Start creating your configuration by selecting a control mode (self-adjusting modules only).
Page 39
For a description of each display mode, refer to Display Modes on page 6. MPORTANT For the IQS-3150 Variable Attenuator, the absolute (or total) attenuation is the actual optical insertion loss between the input and output ports, including connector losses.
Page 40
Setting Up Your Variable Attenuator Control Center Settings and Controls To select a display mode: 1. Click the Instrument function tab. The selected display mode 2. Under Control Center, enter the appropriate settings. 3. Under Mode click the appropriate button. The selected display mode appears next to Mode on the data display.
Page 41
Selecting a Wavelength and a Fine-Tuning Step The attenuator wavelength must be set as closely as possible to the wavelength of the optical source. The IQS-3150 Variable Attenuator module provides a wide range of wavelengths: 1250 nm to 1650 nm for singlemode modules and 700 nm to 1350 nm for multimode modules.
Page 42
Although EXFO guarantees that the minimum insertion loss is below a specified value (refer to specification sheet), it may vary slightly from one wavelength to another and from one IQS-3150 Variable Attenuator to another. To change the attenuation or output-power level: 1.
Page 43
Note: The offset values must be between -99.999 dB and 99.999 dB. The attenuation value is positive; therefore, when the offset value is positive, the displayed attenuation increases. IQS-3150 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Creating a Test Sequence Creating a Test Sequence The IQS-3150 allows you to create test sequences so that the attenuation or output power steps are performed automatically without your intervention. The sequences can be saved and retrieved to be used as is or to be used as a template in which you can insert or remove steps.
Page 45
To add, insert, and remove steps: 1. On the Settings function tab, click the Sequencer tab. 2. Under Sequence Steps, select the control mode. IQS-3150 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 46
Setting Up Your Variable Attenuator Creating a Test Sequence 3. In the Attenuation or the Output Power box (depending on the selected control mode) enter the attenuation or the output power level you need. In Attenuation mode In Output Power mode 4.
Page 47
1. On the Settings function tab, click the Sequencer tab. 2. Under Sequence File, open a test sequence or create one (refer to Adding, Inserting, and Removing Steps on page 38). IQS-3150 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 48
MPORTANT When using the Absolute start time mode, make sure that the clock of your IQS Platforms is correctly set. The IQS-3150 dedicated hardware uses that clock setting as time reference. 5. Under Sequence File, click Save As if you want to save that sequence.
Page 49
1. On the Settings function tab, click the Sequencer tab. 2. Under Sequence File, open a test sequence. Create a sequence (refer to Adding, Inserting, and Removing Steps on page 38). IQS-3150 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 50
Setting Up Your Variable Attenuator Creating a Test Sequence 3. Under Sequence Loop, click Loop Count and, in the text box, enter the number of times the sequence must be repeated. Click the Continuous Loop button. 4. Under Sequence File, click Save As if you want to save that sequence. Variable Attenuator Artisan Technology Group - Quality Instrumentation ...
Sequencer tab of the Settings function tab. Clicking the New button clears all previous settings allowing you to build a completely new sequence. IQS-3150 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 52
from which you can select a directory to save your sequence file. Note: To facilitate the search of sequence files, EXFO recommends that you use the following elements in the file name: step attenuation or output power level, step duration, and sequence repetition scheme.
Setting Up Your Variable Attenuator Saving and Recalling Configurations Saving and Recalling Configurations Once you have set the IQS-3150 Variable Attenuator parameters, you can save your custom configuration and recall it at any time. You can also recall the factory-defined settings.
Page 54
Setting Up Your Variable Attenuator Saving and Recalling Configurations To recall a configuration: 1. Select the Configuration function tab. 2. Click Open. 3. Select the configuration file you wish to recall and confirm your action. You are returned to the application and the new parameters are set. To revert to factory settings: 1.
To ensure maximum power and to avoid erroneous readings: Always inspect fiber ends and make sure that they are clean as explained below before inserting them into the port. EXFO is not responsible for damage or errors caused by bad fiber cleaning or handling.
Page 57
EXFO uses good quality connectors in compliance with EIA-455-21A standards. To keep connectors clean and in good condition, EXFO strongly recommends inspecting them with a fiber inspection probe before connecting them. Failure to do so will result in permanent damage to the connectors and degradation in measurements.
Operating the IQS-3150 Installing the EXFO Universal Interface (EUI) Installing the EXFO Universal Interface (EUI) The EUI fixed baseplate is available for connectors with angled (APC) or non-angled (UPC) polishing. A green border around the baseplate indicates that it is for APC-type connectors.
Temperature and humidity variations affect the performance of electronic circuits and optical detectors, which can offset measurement results. To compensate for this offset, the IQS-3150 is equipped with an offset nulling function. EXFO recommends performing a nulling of the electrical offsets whenever environmental conditions change.
Page 60
Operating the IQS-3150 Nulling Electrical Offsets To perform the power meter nulling: 1. Click the Instrument function tab. 2. Click the Nulling button. Variable Attenuator Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Operating the IQS-3150 Running an Attenuation Sequence Running an Attenuation Sequence Attenuation sequences allow you to automate and ease your testing process. Prepare the test sequence as described in Creating a Test Sequence on page 37. To start an attenuation sequence: 1.
Page 62
Operating the IQS-3150 Running an Attenuation Sequence You can interrupt a sequence at any time by clicking Pause; click Resume when you are ready to continue. Note: When you click the Pause button, the sequence will not be restarted at the point you paused it.
Operating the IQS-3150 Using the Power Tracking Function (Self-Adjusting Modules) Using the Power Tracking Function (Self-Adjusting Modules) The power tracking function is used to monitor, when in the Output Power control mode, the output power level and automatically adjust the attenuation to keep the output power to the requested level.
Operating the IQS-3150 Using the Shutter Using the Shutter The shutter is used to let light through the input or block it. AUTION Using the shutter continuously, at a rate of one cycle per three seconds, may damage the instrument permanently or seriously reduce its life cycle.
Page 65
Operating the IQS-3150 Using the Shutter Shutter Status The status of the shutter is shown on the left of the data display. Open Closed It is also shown on the Shutter (red) LED push button on the front panel of the module;...
Controlling Multiple Variable Attenuators With your platform, you can set common parameters and simultaneously operate several modules of the same kind in a single interface, which is particularly useful in larger systems. Note: You should be familiar with the configuration and operation of a single module before controlling multiple modules simultaneously.
1. On the Modules/Config function tab, select the boxes corresponding to the modules you want to control. Click Select All if you want to work with all IQS-3150 Variable Attenuator modules. 2. Click Apply Selections and click the Instruments function tab.
Controls on page 31.) Controlling a Single IQS-3150 Variable Attenuator You may want to control a specific module among all the IQS-3150 Variable Attenuator modules that you have in the system. To control a specific IQS-3150 Variable Attenuator: 1. Make sure that the row corresponding to the module you want to control appears in bold or that it is highlighted.
Monitoring Variable Attenuator Modules When using your IQS-3150 Variable Attenuator module, either alone or with other modules in a test setup, you can view module data and status using its monitor window in IQS Manager. Using Monitor Windows Monitor windows display basic data about modules. A combination of resizable windows allows you to create an integrated data display (refer to the platform user guide).
Page 71
If you want to monitor all the modules in the current unit, click Select All Monitors. If you want to clear your choices, click Deselect All Monitors. IQS-3150 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 72
Monitoring Variable Attenuator Modules Using Monitor Windows 3. Click Start Monitor to apply your selection. IQS Manager will display the selected monitor windows on the Monitors function tab. Note: To start the highlighted module’s corresponding application at the same time, click Start App. & Monitor. The application will appear in a different window.
QuickTools, click Show Controller. Output Power Attenuation control mode control mode For more information on settings and controls, refer to Control Center Settings and Controls on page 31. IQS-3150 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 74
Monitoring Variable Attenuator Modules Using QuickTools To close QuickTools: Click the Close button located at the top of the window. Click outside the QuickTools window. To close a monitor window: Click the button on the upper left of the monitor window and select Remove Monitor.
Measuring Multimode Insertion Loss Often, when using a multimode source (mostly LED sources), part of the optical energy is transmitted into the fiber cladding. These cladding modes attenuate rapidly, but will affect power meter readings if the source is connected using only a short jumper, as would be the case when taking a reference before measuring insertion loss.
Page 77
A mandrel wrap is not the preferred method of controlling cladding modes in multimode fibers. IQS-3150 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Maintenance To help ensure long, trouble-free operation: Always inspect fiber-optic connectors before using them and clean them if necessary. Keep the unit free of dust. Clean the unit casing and front panel with a cloth slightly dampened with water.
Do not try to disassemble the unit. Doing so would break the connector. ARNING Looking into the optical connector while the light source is active WILL result in permanent eye damage. EXFO strongly recommends to TURN OFF the unit before proceeding with the cleaning procedure.
Page 80
9. Continue to turn as you withdraw the cleaning tip. 10. Repeat steps 7 to 9, but this time with a dry cleaning tip (2.5 mm tip provided by EXFO). Note: Make sure you don’t touch the soft end of the cleaning tip and verify the cleanliness of the cotton tip.
ARNING Looking into the optical connector while the light source is active WILL result in permanent eye damage. EXFO strongly recommends to TURN OFF the unit before proceeding with the cleaning procedure.
Page 82
6d. Verify connector surface with a portable fiber-optic microscope (for example, EXFO’s FOMS) or fiber inspection probe (for example, EXFO’s FIP). 7. Put the EUI back onto the instrument (push and turn clockwise).
5. Repeat step 4 with a dry cleaning tip or blow dry with compressed air. 6. Discard the cleaning tips after one use. IQS-3150 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
(home) position to reestablish its relative position on the range of attenuation or output power levels. EXFO recommends that you perform the homing procedure when the homing icon appears on the data display. To home the attenuator: 1.
Under normal use, the recommended interval for your IQS-3150 Variable Attenuator is: one year. For newly delivered units, EXFO has determined that the storage of this product for up to six months between calibration and shipment does not affect its performance (EXFO Policy PL-03).
To ensure that your unit conforms to the published specifications, calibration may be carried out at an EXFO service center or, depending on the product, at one of EXFO’s certified service centers. Calibrations at EXFO are performed using standards traceable to national metrology institutes.
Troubleshooting Viewing Online Documentation An online version of the IQS-3150 Variable Attenuator user guide is available at all times from the application. To access the online user guide: Click Help in the function bar. Variable Attenuator Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Contacting the Technical Support Group To obtain after-sales service or technical support for this product, contact EXFO at one of the following numbers. The Technical Support Group is available to take your calls from Monday to Friday, 8:00 a.m. to 7:00 p.m.
Page 90
Select the Technical Support tab to view phone numbers and active Internet links to EXFO’s Technical Support Group. Use these links to send an information request by e-mail or to access EXFO’s web site. Select the Module Information tab to view the module identification, ...
Pack the unit in its original packing material when shipping. Avoid high humidity or large temperature fluctuations. Keep the unit out of direct sunlight. Avoid unnecessary shocks and vibrations. IQS-3150 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES. Liability EXFO shall not be liable for damages resulting from the use of the product, nor shall be responsible for any failure in the performance of other items to which the product is connected or the operation of any system of which the product may be a part.
Warranty Exclusions Exclusions EXFO reserves the right to make changes in the design or construction of any of its products at any time without incurring obligation to make any changes whatsoever on units purchased. Accessories, including but not limited to fuses, pilot lamps, batteries and universal interfaces (EUI) used with EXFO products are not covered by this warranty.
5. Return the equipment, prepaid, to the address given to you by support personnel. Be sure to write the RMA number on the shipping slip. EXFO will refuse and return any package that does not bear an RMA number.
National Highway 107, Xixiang, Bao An District, Shenzhen, China, 518126 To view EXFO's network of partner-operated Certified Service Centers nearest you, please consult EXFO's corporate website for the complete list of service partners: http://www.exfo.com/support/services/instrument-services/ exfo-service-centers. IQS-3150 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
MPORTANT The following technical specifications can change without notice. The information presented in this section is provided as a reference only. To obtain this product’s most recent technical specifications, visit the EXFO Web site at www.exfo.com. SPECIFICATIONS Singlemode configurations Description...
Page 97
Technical Specifications Multimode configurations Description Without power monitoring With power monitoring Models IQS-3150-C; D IQS-3150-CI; DI Fiber type (μm) 50/125, 62.5/125 50/125, 62.5/125 Wavelength range (nm) 700 to 1350 700 to 1350 Max. attenuation (dB) Insertion loss (dB) Typical Max.
SCPI Command Reference This appendix presents detailed information on the commands and queries supplied with your IQS-3150 Variable Attenuator. MPORTANT Since the IQS controllers and expansion units can house many instruments, you must explicitly specify which instrument you want to remotely control.
(returned value is not 0). Notes This command will take at least 15 seconds to complete. See Also :SENSe[1..n]:CORRection:COLLect:ZERO :STATus:OPERation:BIT<n>:CONDition? :STATus:QUEStionable:BIT<n>:CONDition? IQS-3150 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 102
SCPI Command Reference Product-Specific Commands—Description :CONTrol[1..n]:MODE Description This command selects the attenuator's control mode. At *RST, the control mode is ATTenuation. Syntax :CONTrol[1..n]:MODE<wsp>ATTenuation| POWer Parameter(s) Parameter 1: The program data syntax for the first parameter is defined as a <CHARACTER PROGRAM DATA> element.
Page 103
ATTENUATION: the attenuation control mode is selected. POWER: the power control mode is selected. Example(s) CONT:MODE POW CONT:MODE? Returns POWER See Also :CONTrol[1..n]:MODE :INPut[1..n]:ATTenuation :INPut[1..n]:RATTenuation :OUTPut[1..n]:POWer :OUTPut[1..n]:RPOWer IQS-3150 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 104
SCPI Command Reference Product-Specific Commands—Description :INPut[1..n]:ARESolution? Description This query returns the smallest attenuation step available. Use this command to determine the maximum resolution of the attenuation. *RST has no effect on this command. Syntax :INPut[1..n]:ARESolution? Parameter(s) None Response Syntax <Resolution> Response(s) Resolution: The response data syntax for <Resolution>...
Page 105
MAXimum and DEFault are accepted on input. MINimum allows to set the instrument to the smallest supported value. MAXimum allows to set the instrument to the highest supported value. IQS-3150 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 106
SCPI Command Reference Product-Specific Commands—Description :INPut[1..n]:ATTenuation DEFault allows the instrument to select a value for the <Attenuation> parameter. The <Attenuation> parameter corresponds to a valid attenuation value. You can use the INPut[1..n]:ATTenuation? MAX and INPut[1..n]:ATTenuation? MIN queries to determine a valid attenuation range for the current wavelength.
Page 107
MINimum is used to retrieve the instrument's smallest supported value. MAXimum is used to retrieve the instrument's highest supported value. DEFault is used to retrieve the instrument's default value. Response Syntax <Attenuation> IQS-3150 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 108
SCPI Command Reference Product-Specific Commands—Description :INPut[1..n]:ATTenuation? Response(s) Attenuation: The response data syntax for <Attenuation> is defined as a <NR3 NUMERIC RESPONSE DATA> element. The <Attenuation> response represents either the current or the MINimum/MAXimum absolute attenuation, in dB. Example(s) INP:WAV 1310 NM CONT:MODE ATT INP:ATT 25.30 INP:ATT? Returns: 2.530000E+001...
Page 109
The <Offset> parameter corresponds to a valid offset value. You can use the INPut[1..n]:OFFSet? MAX and INPut[1..n]:OFFSet? MIN queries to determine a valid range for the attenuation offset. IQS-3150 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 110
SCPI Command Reference Product-Specific Commands—Description :INPut[1..n]:OFFSet Example(s) INP:WAV 1310 NM CONT:MODE ATT OUTP:APM ABS INP:OFFS DEF INP:ATT 20.50 DB INP:ATT? Returns: 2.050000E+001 INP:RATT? Returns: 2.050000E+001 INP:OFFS –5.000 DB INP:ATT? Returns: 2.050000E+001 INP:RATT? Returns: 1.550000E+001 INP:OFFS 4.000 DB INP:ATT? Returns: 2.050000E+001 INP:RATT? Returns: 2.450000E+001 See Also :INPut[1..n]:OFFSet?
Page 111
MINimum is used to retrieve the instrument's lowest supported value. MAXimum is used to retrieve the instrument's highest supported value. DEFault is used to retrieve the instrument's default value. Response Syntax <Offset> IQS-3150 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 112
SCPI Command Reference Product-Specific Commands—Description :INPut[1..n]:OFFSet? Response(s) Offset: The response data syntax for <Offset> is defined as a <NR3 NUMERIC RESPONSE DATA> element. The <Offset> response represents either the current or the MINimum/MAXimum offset setting in dB. Example(s) CONT:MODE ATT INP:OFFS 12.482 INP:OFFS? Returns: 1.248200E+001 See Also...
Page 113
MINimum allows to set the instrument to the lowest supported value. MAXimum allows to set the instrument to the highest supported value. IQS-3150 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 114
SCPI Command Reference Product-Specific Commands—Description :INPut[1..n]:RATTenuation DEFault allows the instrument to select a value for the <RelativeAttenuation> parameter. The <RelativeAttenuation> parameter is a valid relative attenuation value. You can use the INPut[1..n]:RATTenuation? MAX and INPut[1..n]:RATTenuation? MIN queries to determine a valid range for the attenuation. a) In ABSolute mode, <RelativeAttenuation>...
Page 115
0. INP:ATT? Returns: 1.135500E+001 INP:RATT? Returns: -2.000000E+000 INP:RATT MIN See Also :CONTrol[1..n]:MODE :OUTPut[1..n]:APMode :INPut[1..n]:ATTenuation :INPut[1..n]:OFFSet :INPut[1..n]:RATTenuation? :INPut[1..n]:REFerence :STATus:OPERation:BIT<n>:CONDition? :OUTPut[1..n]:RPOWer IQS-3150 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 116
SCPI Command Reference Product-Specific Commands—Description :INPut[1..n]:RATTenuation? Description This query returns either the current or the minimum/maximum relative attenuation. At *RST, the relative attenuation value that will be set depends on the instrument you have. Syntax :INPut[1..n]:RATTenuation?[<wsp>MAXimum| MINimum|DEFault] Parameter(s) Parameter 1: The program data syntax for the first parameter is defined as a <CHARACTER PROGRAM DATA>...
Page 117
(absolute attenuation * –1) + input power (wavelength-specific) + offset value. Example(s) INP:RATT 15.355 DB INP:RATT? Returns: 1.535500E+001 See Also :CONTrol[1..n]:MODE :OUTPut[1..n]:APMode :INPut[1..n]:ATTenuation? :INPut[1..n]:OFFSet :INPut[1..n]:RATTenuation :INPut[1..n]:REFerence IQS-3150 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 118
SCPI Command Reference Product-Specific Commands—Description :INPut[1..n]:REFerence Description This command sets, for the current wavelength, a reference value for the attenuation. When the instrument is used in Reference mode, the attenuation configured with the INPut[1..n]:RATTenuation command is relative to this reference value. This command will have no effect when the instrument is used in Absolute or X + B mode.
Page 119
INP:RATT 33.865 DB OUTP:APM REF INP:RATT? Returns: 0.000000E+001 INP:REF? Returns: 3.386500E+001 INP:REF 12.345 DB INP:RATT? Returns: 2.152000E+001 INP:REF MIN See Also :INPut[1..n]:RATTenuation :INPut[1..n]:REFerence? :OUTPut[1..n]:APMode :OUTPut[1..n]:APMode? :OUTPut[1..n]:REFerence IQS-3150 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 120
SCPI Command Reference Product-Specific Commands—Description :INPut[1..n]:REFerence? Description This query returns either the current or the minimum/maximum reference value for the attenuation. At *RST, the reference value that will be set depends on the instrument you have. Syntax :INPut[1..n]:REFerence?[<wsp>MAXimum|MINi mum|DEFault] Parameter(s) Parameter 1: The program data syntax for the first parameter is defined as a <CHARACTER PROGRAM DATA>...
Page 121
The <Reference> response represents either the current or the MINimum/MAXimum reference value in dB. Example(s) INP:WAV 1310 NM CONT:MODE ATT OUTP:APM REF INP:REF? See Also :INPut[1..n]:RATTenuation? :INPut[1..n]:REFerence :OUTPut[1..n]:APMode :OUTPut[1..n]:APMode? :OUTPut[1..n]:REFerence IQS-3150 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 122
SCPI Command Reference Product-Specific Commands—Description :INPut[1..n]:WAVelength Description This command selects a specific wavelength. At *RST, the wavelength that will be selected depends on the instrument you have. Syntax :INPut[1..n]:WAVelength<wsp><Wavelength[< wsp>M]>|MAXimum|MINimum|DEFault Parameter(s) Wavelength: The program data syntax for <Wavelength> is defined as a <numeric_value> element followed by an optional <SUFFIX PROGRAM DATA>...
Page 123
INP:WAV 0.000001550 M STAT:OPER:BIT8:COND? Keep sending the query as long as attenuation is not reached. When attenuation is reached, the returned value is 0. See Also :INPut[1..n]:WAVelength? :STAT:OPER:BIT:COND? IQS-3150 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 124
SCPI Command Reference Product-Specific Commands—Description :INPut[1..n]:WAVelength? Description This query returns a value indicating either the current or the minimum/maximum wavelength. At *RST, the wavelength that will be selected depends on the instrument you have. Syntax :INPut[1..n]:WAVelength?[<wsp>MAXimum|MI Nimum|DEFault] Parameter(s) Parameter 1: The program data syntax for the first parameter is defined as a <CHARACTER PROGRAM DATA>...
Page 125
MINimum/MAXimum wavelength setting, in meters. Example(s) INP:WAV? MAX Returns: the maximum valid wavelength. INP:WAV 1310 NM INP:WAV? Returns: 1.310000E–006. See Also :INPut[1..n]:WAVelength IQS-3150 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 126
SCPI Command Reference Product-Specific Commands—Description :OUTPut[1..n]:ALC[:STATe] Description This command activates or deactivates the power tracking that controls the output power level. The power tracking is done via the ALC (Automatic Leveling Control) loop. The state of the ALC loop (on or off) is used only when the POWer control mode is active.
Page 127
ALC (Automatic Leveling Control) loop. 0: No power tracking will be performed. 1: Power tracking is activated. See Also :OUTPut[1..n]:ALC[:STATe] :CONTrol[1..n]:MODE :OUTPut[1..n]:DTOlerance :OUTPut[1..n]:POWer :OUTPut[1..n]:RPOWer IQS-3150 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 128
SCPI Command Reference Product-Specific Commands—Description :OUTPut[1..n]:APMode Description This command selects, for the active control mode (ATTenuation or POWer), the operation mode (ABSolute, REFerence or X+B ). At *RST, the operation mode is ABSolute for both control modes (ATTenuation and POWer). Syntax :OUTPut[1..n]:APMode<wsp>ABSolute|XB|REF erence...
Page 129
Since the operation mode applies to the active control mode, you must first define the control mode with the :CONTrol[1..n]:MODE command. See Also :CONTrol[1..n]:MODE :INPut[1..n]:RATTenuation :OUTPut[1..n]:APMode? :OUTPut[1..n]:RPOWer IQS-3150 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 130
SCPI Command Reference Product-Specific Commands—Description :OUTPut[1..n]:APMode? Description This query returns, for active control mode (ATTenuation or POWer), the current operation mode (ABSolute|XB|REFerence). At *RST, the operation mode is ABSolute for both control modes (ATTenuation and POWer). Syntax :OUTPut[1..n]:APMode? Parameter(s) None Response Syntax <Mode>...
Page 131
MINimum, MAXimum and DEFault are accepted on input. MINimum allows to set the instrument to the lowest supported value. MAXimum allows to set the instrument to the highest supported value. IQS-3150 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 132
SCPI Command Reference Product-Specific Commands—Description :OUTPut[1..n]:DTOlerance DEFault allows the instrument to select a value for the <Drift> parameter. The <Drift> parameter corresponds to a valid drift tolerance for the power tracking via the ALC loop, in dB. You can use the OUTPut[1..n]:DTOlerance? MAX and OUTPut[1..n]:DTOlerance? MIN queries to determine a valid range for the drift tolerance.
Page 133
MINimum is used to retrieve the instrument's lowest supported value. MAXimum is used to retrieve the instrument's highest supported value. DEFault is used to retrieve the instrument's default value. Response Syntax <Drift> IQS-3150 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 134
SCPI Command Reference Product-Specific Commands—Description :OUTPut[1..n]:DTOlerance? Response(s) Drift: The response data syntax for <Drift> is defined as a <NR3 NUMERIC RESPONSE DATA> element. The <Drift> response corresponds to either the current or the MINimum/MAXimum drift tolerance that is used for power tracking via the ALC (Automatic Leveling Control) loop.
Page 135
(located on the instrument’s front panel). Example(s) OUTP:LOCK:STAT? Returns: 0 (The shutter is unlocked and can be controlled using the OUTup[1..n][:STATe] command.) See Also :OUTPut[1..n][:STATe] IQS-3150 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 136
SCPI Command Reference Product-Specific Commands—Description :OUTPut[1..n]:OFFSet Description This command sets a power offset value. The power offset value will be added to the absolute output power.The same power offset value will be used for all wavelengths. The offset is only taken into account when the OUTut[1..n]:RPOWer command is used.
Page 137
OUTP:OFFS 0.000 DB OUTP:POW -5.500 DBM OUTP:POW? Returns: -5.500000E+000 OUTP:RPOW? Returns: -5.500000E+000 OUTP:OFFS -1.500 DB OUTP:POW? Returns: -5.500000E+000 OUTP:RPOW? Returns: -7.000000E+000 OUTP:OFFS MAX See Also :INPut[1..n]:OFFSet :OUTPut[1..n]:OFFSet? :OUTPut[1..n]:RPOWer IQS-3150 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 138
SCPI Command Reference Product-Specific Commands—Description :OUTPut[1..n]:OFFSet? Description This query returns a value indicating either the current or the minimum/maximum power offset setting. At *RST, this value is set to 0 dB. Syntax :OUTPut[1..n]:OFFSet?[<wsp>MAXimum|MINi mum|DEFault] Parameter(s) Parameter 1: The program data syntax for the first parameter is defined as a <CHARACTER PROGRAM DATA>...
Page 139
The <Offset> response corresponds to either the current or the MINimum/MAXimum power offset value in dB. Example(s) CONT:MODE POW OUTP:OFFS -5.000 DB OUTP:OFFS? Returns: -5.000000E+000 See Also :INPut[1..n]:OFFSet? :OUTPut[1..n]:OFFSet :OUTPut[1..n]:RPOWer IQS-3150 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 140
SCPI Command Reference Product-Specific Commands—Description :OUTPut[1..n]:POWer Description This command sets the absolute output power to a specific value. The valid range of values depends on the type of instrument, the configuration, the current wavelength, and the input power. This value is used only when the POWer control mode is active.
Page 141
When output power is reached, the returned value is 0. See Also INPut[1..n]:ATTenuation OUTPut[1..n]:ALC[:STATe] OUTPut[1..n]:DTOlerance OUTPut[1..n]:POWer? OUTPut[1..n]:RPOWer? :STATus:OPERation:BIT<n>:CONDition? IQS-3150 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 142
SCPI Command Reference Product-Specific Commands—Description :OUTPut[1..n]:POWer? Description This query returns a value indicating either the current or the minimum/maximum absolute power value. At *RST, the value that will be set is device-dependent. Syntax :OUTPut[1..n]:POWer?[<wsp>MAXimum| MINimum|DEFault] Parameter(s) Parameter 1: The program data syntax for the first parameter is defined as a <CHARACTER PROGRAM DATA>...
Page 143
MINimum/MAXimum absolute power value, in dBm. Example(s) INP:WAV 1310 NM CONT:MODE POW OUTP:POW -15.000 DBM OUTP:POW? Returns -1.500000E+001 See Also :OUTPut[1..n]:ALC[:STATe]? :OUTPut[1..n]:DTOlerance? :OUTPut[1..n]:POWer :OUTPut[1..n]:RPOWer? IQS-3150 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 144
SCPI Command Reference Product-Specific Commands—Description :OUTPut[1..n]:REFerence Description This command sets a power reference value for the current wavelength. When the instrument is used in REFerence mode, the power is relative to this reference value. This command will have no effect when the instrument is used in Absolute or X + B mode.
Page 146
SCPI Command Reference Product-Specific Commands—Description :OUTPut[1..n]:REFerence? Description This query returns either the current or the minimum/maximum output power reference value. At *RST, the value that will be set depends on the instrument you have. Syntax :OUTPut[1..n]:REFerence?[<wsp>MAXimum| MINimum|DEFault] Parameter(s) Parameter 1: The program data syntax for the first parameter is defined as a <CHARACTER PROGRAM DATA>...
Page 147
MINimum/MAXimum power reference value in dBm. Example(s) INP:WAV 1310 NM CONT:MODE POW OUTP:APM REF OUTP:REF 12.345 DBM OUTP:REF? Returns: 1.234500E+001 See Also :INPut[1..n]:REFerence :OUTPut[1..n]:APMode :OUTPut[1..n]:OFFSet :OUTPut[1..n]:REFerence :OUTPut[1..n]:RPOWer IQS-3150 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 148
SCPI Command Reference Product-Specific Commands—Description :OUTPut[1..n]:RPOWer Description This command sets the relative power to a specific value. The valid range of values depends on the type of instrument, the configuration, and the input power. This value is used only when the POWer control mode is active.
Page 150
SCPI Command Reference Product-Specific Commands—Description :OUTPut[1..n]:RPOWer? Description This query returns a value indicating either the current or the minimum/maximum relative power value. At *RST, the value that will be set depends on the instrument you have. Syntax :OUTPut[1..n]:RPOWer?[<wsp>MAXimum|MINi mum|DEFault] Parameter(s) Parameter 1: The program data syntax for the first parameter is defined as a <CHARACTER PROGRAM DATA>...
Page 152
SCPI Command Reference Product-Specific Commands—Description :OUTPut[1..n][:STATe] Description This command controls the state of the instrument's shutter (open or closed). At *RST, the state of the shutter is set to off (closed). Syntax :OUTPut[1..n][:STATe]<wsp><ShutterState> Parameter(s) ShutterState: The program data syntax for <ShutterState> is defined as a <Boolean Program Data>...
Page 153
0: the shutter is closed (no light is transmitted). 1: the shutter is open (allows light transmission). Example(s) OUTP:STAT ON OUTP:STAT? Returns: 1 (the shutter is open) See Also :OUTPut[1..n][:STATe] :OUTPut[1..n]:LOCK[:STATe]? IQS-3150 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 154
SCPI Command Reference Product-Specific Commands—Description :READ[1..n][:SCALar]:POWer:DC? Description This query returns the power measured at the instrument's input port. This command is an event and has no associated *RST condition or query form. Syntax :READ[1..n][:SCALar]:POWer:DC? Parameter(s) None Response Syntax <PowerMeasurement> Response(s) PowerMeasurement: The response data syntax for <PowerMeasurement>...
Page 155
(returned value is not 0). Notes This command will take at least 3 seconds to complete. See Also :CALibration[1..n]:ZERO :STATus:OPERation:BIT<n>:CONDition? IQS-3150 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 156
SCPI Command Reference Product-Specific Commands—Description :SNUMber? Description This query returns a value indicating the instrument's serial number This command is an event and has no associated *RST condition or query form. Syntax :SNUMber? Parameter(s) None Response Syntax <SerialNumber> Response(s) SerialNumber: The response data syntax for <SerialNumber>...
Page 157
STAT? Keep sending the query as long as the returned value is "BUSY". When the operation is complete, the returned value sould be "READY". See Also :STATus:OPERation:BIT<n>:CONDition? IQS-3150 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 158
SCPI Command Reference Product-Specific Commands—Description :STATus:OPERation:BIT<n>:CONDition? Description This query returns the state of a specific bit in the OPERation register set. The <n>, ("bit <n>") indicates for which bit the information must be retrieved in the :STATus:OPERation status register. The <n> value must be a number from 8 to 12.
Page 159
Bit <10>: When the returned value is 1, the nulling of the offsets on the internal power meter is in progress. Example(s) STAT:OPER:BIT8:COND? See Also CALibration[1..n]:ZERO SENSe[1..n]:CORRection:COLLect:ZERO STATus? STATus:QUEStionable:BIT<n>:CONDition? IQS-3150 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 160
The meaning of the response depends on the value returned for bit <n>. Bit <9>: When the value is 1, EXFO recommends that the instrument’s mechanism be returned to its home position (CALibration[1..n]:ZERO). This operation must be performed after many moves of the instrument’s mechanism or when variations in...
Page 161
Bit <10>: When the returned value is 1, the operation temperature is outside the recommended operation temperature range as indicated in the instrument’s specifications. Example(s) STAT:QUES:BIT9:COND? See Also :CALibration[1..n]:ZERO :STATus:OPERation:BIT<n>:CONDition? IQS-3150 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
........37 front panel..........71 after-sales service ........82 closing monitor window......67 application configuration..........23 contacting EXFO support from ....83 recall ............46 exiting ........... 21 save............46 multimodule ..........7 connectors, cleaning......72, 74 starting, single-module......
Page 163
......... 51 input port, module ........1 EUI connectors, cleaning ......74 inserting a module ........11 EXFO support e-mail ........83 insertion loss. see IL EXFO universal interface. see EUI EXFO Web site..........83 exiting application........21 label, identification........
Page 164
Index monitoring ..........63 removal ..........11 padlock icon ..........57 status............. 19 PDF. see online user guide module information performing null measurement ..... 52 firmware version number ...... 83 ports, module front panel ......1 module identification number ....83 position, module .........
Page 165
87 service centers ..........88 setting up the variable attenuator....23 settings variation, of IL value ........35 Control Center ........31 shipping to EXFO ........87 shutter warranty caution ..........57 certification..........86 locked............ 57 exclusions ..........86 opening/closing ........
Page 166
CHINESE REGULATION ON RESTRICTION OF HAZARDOUS SUBSTANCES NAMES AND CONTENTS OF THE TOXIC OR HAZARDOUS SUBSTANCES OR ELEMENTS CONTAINED IN THIS EXFO PRODUCT EXFO Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement in SJ/T11363-2006...
Page 167
MARKING REQUIREMENTS Product Environmental protection use period (years) Logo This E product EXFO Battery If applicable. Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 169
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment SERVICE CENTER REPAIRS WE BUY USED EQUIPMENT • FAST SHIPPING AND DELIVERY Experienced engineers and technicians on staff Sell your excess, underutilized, and idle used equipment at our full-service, in-house repair center We also offer credit for buy-backs and trade-ins •...
Need help?
Do you have a question about the IQS-3150 and is the answer not in the manual?
Questions and answers