Operation; General; Filling The Water Heater; Initial Start Up - State Water Heaters SSED 5 Instruction Manual

Commercial electric water heaters
Table of Contents

Advertisement

General

Refer to the Features and Components section of this manual for the
location of components mentioned in the instructions that follow.
neVer operate the heating elements without being certain the water
heater is filled with water, and a temperature and pressure relief valve
is installed in the relief valve opening on top of the heater.
The pilot switch (power on/off toggle switch) on the cabinet front
permits the heater to be turned on and off without having to operate
the electrical disconnect switch.
Optional manual override switches on the cabinet front allow elements
to be manually de-energized if full capacity is not needed.

fIllInG the Water heater

To fill the water heater with water:
1.
Turn off the electrical disconnect switch.
2.
Turn off pilot toggle switch.
3.
Close the heater drain valve.
4.
Open a nearby hot water faucet to allow the air in the system to escape.
5.
Fully open the cold water inlet valve, filling the heater and piping.
6.
Close the hot water faucet when water starts to flow from the
faucet. Leave the cold water inlet valve fully open. The heater is
now ready for start up and temperature regulation.
7.
Close the cabinet door and perform start up checks listed below
before turning on the electricity.

operatIon

InItIal start up

The following checks should be made by the installer when the water
heater is placed into operation for the first time:
1.
Check all factory and field made water and electrical
connections for tightness. Also check connections on top of the
heater. Repair water leaks and tighten electrical connections
as necessary.
2.
Turn on the electrical disconnect switch and pilot toggle switch.
The pilot toggle switch is located on cabinet.
3.
Observe the operation of the electrical components during the
first heating cycle. use care as the electrical circuits are
energized.
Temperature control and contactor operation should be checked
by allowing heater to come up to temperature and shut off
automatically. use care as the electrIcal cIrcuIts are
enerGIZed.

draInInG the Water heater

To drain the water heater storage tank:
1. Turn off the electrical supply to the water heater at the circuit
breaker or disconnect switch.
2. Turn off the pilot toggle switch on the water heater.
3. Ensure the cold water inlet valve is open.
4. Open a nearby hot water faucet and let the water run until the
water is no longer hot.
5. Close the cold water inlet valve to the water heater.
6. Connect a hose to the water heater drain valve and terminate it
to an adequate drain.
7. Open the water heater drain valve and allow all the water to drain
from the storage tank.
8. Close the water heater drain valve when all water in the storage
tank has drained.
9. Close the hot water faucet opened in Step 4.
10. If the water heater is going to be shut down for an extended
period, the drain valve should be left open.
15