  • Page 2 SKIN Energy Energy Energy Energy Energy Energy Energy Energy...
  • Page 3 No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without the express written permission of Spectrum Brands. Data is subject to change without notification. ™ ™ REMINGTON and iLIGHT are trademarks of Spectrum Brands, Inc.
  • Page 4: Table Of Contents

    Table of contents Get to know your device ............5 Safety with your device ............6 Contraindications & warnings ..........7 Do not use your device if: .............9 Precautions................9 Safety tips ................10 Possible side effects ............11 Long-term hair removal .............13 Get started ................17 10.
  • Page 5: Get To Know Your Device

    1. GET TO KNOW YOUR DEVICE The Remington iLIGHT Essential is a light-based device for permanent hair reduction designed for home use. It is a powerful electrical device and should be used with special attention to safety. Be sure to read all warnings, contraindications and safety precautions before use, and follow them strictly.
  • Page 6: Safety With Your Device

    1.3 Indications for use This device is an over-the-counter device intended to remove unwanted hair and effect long-term, or permanent hair reduction. Permanent hair reduction is defined as a long-term, stable reduction in the number of hairs regrowing when measured at 6, 9 and 12 months after the completion of a treatment regimen.
  • Page 7: Contraindications & Warnings

    3. CONTRAINDICATIONS & WARNINGS This device is not designed for everyone. Refer to section "1.3 Indications for use". Hair removal by lasers or intense pulsed light sources can cause increased hair growth in some individuals. The highest risk groups for this response are females of Mediterranean, Middle Eastern and South Asian heritage when used on the face and neck.
  • Page 8 Do not use if you are pregnant or nursing. Do not treat on areas where you may want hair to grow. The results are permanent. Do not treat the same area of skin more than once per hair removal session. Stop use immediately if your skin is very red, or if your skin blisters or burns.
  • Page 9: Do Not Use Your Device If

    4. DO NOT USE YOUR DEVICE IF: The adapter, attachments or accessories for this device are not recommended by Spectrum Brands. The device has a damaged cord or adapter. Keep the power cord away from heated surfaces. You see or smell smoke when it is in use. The skin tone tester, treatment window, or device casing is cracked or coming apart.
  • Page 10: Safety Tips

    Do not use if you have a disease related to photosensitivity, such as porphyria, polymorphic light eruption, solar urticaria, lupus, etc. Do not use if you have a history of skin cancer or areas of potential skin malignancies. Do not use if you have received radiation therapy or chemotherapy treatments within the past 3 months, or have areas of potential skin malignancies.
  • Page 11: Possible Side Effects

    7. POSSIBLE SIDE EFFECTS If you follow the instructions fully and pay attention to all warnings and contraindications, complications and side effects are uncommon. However every cosmetic procedure, including those designed for home use, involves some degree of risk. Therefore, it is important that you understand and accept the risks and complications that may occur with pulsed light hair removal systems designed for home use.
  • Page 12 Blisters or burns Cool the affected area and apply anti-burn cream. Wait until the area has healed completely before another treatment, and use a lower energy level. If the skin does not return to normal within 3 days, contact Customer Service. Pigment changes The device targets the hair shaft, in particular the pigmented cells in the hair follicle and the hair follicle itself.
  • Page 13: Long-Term Hair Removal

    8. LONG-TERM HAIR REMOVAL The efficiency of hair removal varies from person to person according to body area, hair color, and how the device is used. A typical full hair growth cycle may take 18-24 months. During this time, multiple treatment sessions are required to achieve permanent hair removal.
  • Page 14 8.2 Energy levels The energy level determines the intensity of the light pulse delivered to your skin. As the energy level increases, so do hair removal results, as well as the risk of possible side effects and complications. The device has 5 levels of energy from 1 (the lowest) to 5 (the highest), represented by 5 energy level indicator lights.
  • Page 15 Gliding is the best technique for working at lower energy levels. Press the treatment window firmly against your skin and slowly glide over your skin (either across or down as shown in the image). Make sure that the treatment window is always touching your skin. At lower energy levels, the device takes only 1-1.5 seconds to recharge between pulses.
  • Page 16 8.5 What to expect when treating with your device For many people, using the device may be their first experience with a light-based device. During a treatment session it is normal to experience or feel: Noise: The cooling fan makes noise similar to a hair dryer. This is normal.
  • Page 17: Get Started

    9. GET STARTED To use your device follow these steps: Remove the device and other components from box. Plug the adapter cord into the device socket and plug the adapter into an electrical outlet. All energy level indicator lights will turn on, and then go off.
  • Page 18 NOTES: The device will only emit repeated pulses when it is in firm contact with your skin, and you keep moving it across your skin. Use a lower energy level if you experience any discomfort. Be sure to do a spot test for each part of the body you wish to treat. 9.2 Treatments with your device Follow these steps each time you treat an area: Before treating an area, the skin should be shaved, clean, dry and...
  • Page 19 The device will not operate if your skin tone is too dark for safe use. If you are pulsing, remove the device from your skin. The device will immediately recharge for the next pulse. After a few seconds (depending on the energy level) the ready light will turn on again, and will pulse when pressed against the skin.
  • Page 20: After Treatment

    10. AFTER TREATMENT When you have finished your treatment session: Press and hold the control button to turn the device off. Remember the last energy level setting you used, because it will not be restored when you turn the device on again. Remove the adapter from the electrical outlet.
  • Page 21: Troubleshooting

    12. TROUBLESHOOTING Do not attempt to open or repair your device. You may expose yourself to dangerous electrical components or pulsed light energy and cause serious harm to yourself. It will also void your warranty. Problem Checks Make sure the adapter is properly connected to the My device does not start.
  • Page 22: Customer Service

    13. CUSTOMER SERVICE For more information about this or other Remington products or to download a PDF of this manual, visit our website at Remingtonproducts.com. Report unexpected operations or events, or any other problem with your device to Customer Service.
  • Page 23: Warranty

    What Does This Warranty Cover? Remington or the authorized dealer from whom you purchased your iLIGHT Essential device shall repair or replace the device, if any material defects caused by Remington are discovered in the device during the warranty period, whether in the body of the device or its operation.
  • Page 24 Remington can charge you for the shipping and repair costs if you agreed to repair the device at your expense. What is not covered by this certificate of warranty? This warranty does not cover any damage resulting from an accident,...
  • Page 25: Disposal

    DISCLAIMERS AND LIMITATIONS MAY NOT APPLY TO YOU. Questions or comments: For more information please visit www.remingtonproducts.com. If your iLIGHT Essential device is broken, damaged, in need of repair, or for any other user assistance, please contact Customer Service: 800-736-4648 or visit www.remingtonproducts.com.
  • Page 26: Specifications

    16. SPECIFICATIONS Model no. IPL3500 Spot size 0.9cm x 3cm [2.7cm²] Technology Home Pulsed Light Maximum energy level Max 4J/cm² Wavelength 475-1200nm Skin tone tester ensures use on Operation & safety appropriate skin types. Package size 180 x 180 x 100 mm System weight 200 gm Transport &...
  • Page 27: Signs And Symbols

    Class II Medical equipment type BF Protection against electrical shock applied part. EC 60601-1 (Safety) This device was tested and IEC 60601-1-2 (EMC) complies with: IEC 60601-1-11 (Environment) IEC60601-2-57 (Safety of non-laser source) Expected service life of the equipment 5 years 17.
  • Page 28: Labeling

    18. LABELING...
  • Page 29: Declarations

    19. DECLARATIONS The use of accessories other than those specified or sold by Spectrum Brands Inc. as replacement parts may have the consequence of increasing the emissions or decreasing the immunity of the device. The device is intended for use in the electromagnetic environment specified in tables 1, 2, 3 and 4.
  • Page 30 Table 2: Guidance and Manufacturer’s Declaration: Electromagnetic Immunity The device is intended for use in the electromagnetic environment specified below. The customer or the user of the devices should assure that it is used in such an environment. IEC 60601 Compliance Electromagnetic Immunity Test...
  • Page 31 Power Power frequency frequency magnetic fields should (50/60 Hz) be at levels characteristic 3 A/m 3 A/m magnetic field of a typical location in a typical commercial 61000-4-8 or hospital environment. Note: UT is the a.c. mains voltage prior to application of the test level.
  • Page 32 Table 3: Guidance and Manufacturer’s Declaration: Electromagnetic Immunity The device is intended for use in the electromagnetic environment specified below. The customer or the user of the device should assure that it is used in such an environment. Immunity Compliance Electromagnetic Environment 60601-1-2 Test...
  • Page 33 Note 1: At 80 MHz and 800 MHz, the higher frequency range applies. Note 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. A. Field strengths from fixed transmitters, such as base stations for radio (cellular/ cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy.
  • Page 34 Table 4: Recommended Separation Distances between Portable and Mobile RF Communications Equipment and the device The device is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the device can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the device as recommended below, according to the maximum output power of...