Power Supply
• Use an AC 220 – 240 V power supply with a
consumption rating of 850 W. Max. 1300 W.
• The length of the power cord is 1.0 m.
The power cord must be connected to the 3+PE
(Pre-earth) plug and far away from the water area.
• Electrical installation work must only be performed
by a qualified electrician. This work must be carried
out in accordance with the regulations according to
IEC 60364-7-701 (corresponding to VDE 0100 Part
701) as well as all national and local regulations.
• The device must be connected to properly grounded
outlet.
Water Supply
• Only use potable water as the water supply.
Using a different water supply (industrial water, well
water, etc.) may cause the durability of the electrical and
mechanical components to deteriorate, resulting in an
accident or malfunction.
• Please firmly fix the water supply pipe.
• In regions where the carbonate hardness exceeds
14° dH (KH), a water filtration system with water
softener must be used. You can inquire about your
carbonate hardness with your local utilities provider.
• In order to ensure a long service life, a service
technician must perform the first descaling within 3
years. After the first descaling, it is recommended to
descale the product every year. (see technical
product information 99.0758.xxx)(decalcifier No. 46
978 000)
Water Pressure
The minimum water pressure must be 0.05 MPa (0.5
bar) [flow pressure]. The maximum water pressure is
1.0 MPa (10.0 bar) [hydrostatic pressure].
Please observe this pressure range in your installation.
Minimum Installation Clearance
For the required minimum installation clearance, refer
to Figure 1.
A space of 70 mm or more on each side of the product is
recommended.
1050 (min.)
Figure 1
10
GB
70 (min.)
700 (min.)
375
70 (min.)
Unit: mm
Confirmation on Construction
• If a toilet from another manufacturer is already fitted,
concealed water connection fitting may be possible.
However, the connection dimensions need to be
identical. The products are sometimes fitted with an
information sticker with the dimensions on the protective
plate underneath the actuator plate.
• The 46944000 fittings can only be installed for Grohe
flush systems with GD2 cisterns.
Technical Data
Rated voltage
220 - 240 V (AC), 50/60 Hz
Rated power consumption
850 W (environment 20°C, water 15°C)
Maximum power consumption
1300 W
Length of the power cord
1 m
Waterproof grade
IPX4
Standby
0.9 Watt
Protection class 1
EN13077-type AB,
EN997-CL1-5A+CL2
Water pressure range
0.05 MPa (0.5 bar) [flow pressure] - 1.0 MPa (10.0 bar)
[hydrostatic pressure]
Water connection cross section
3/8 in
Operating temperature range
0°C - 40°C
Units
V = volt, Hz = hertz, W = watt, m = metre, MPa =
megapascal, in = inch, °C = degrees Celsius
Flushing water volume
Europe: full 5 L, light 3 L
China: full 4.5 L, light 3 L