Siemens RUGGEDCOM RS950G Installation Manual page 41

Hide thumbs Also See for RUGGEDCOM RS950G:
Table of Contents

Advertisement

RUGGEDCOM RS950G
Installation Guide
Test
IEC 61000-4-11
IEC 61000-4-12
IEC 61000-4-16
IEC 61000-4-17
IEC 60255-27
a
Siemens-specified severity levels
IEEE 1613 EMC Immunity Type Tests
NOTE
The RUGGEDCOM RS950G meets Class 2 requirements for an all-fiber configuration and Class 1
requirements for copper ports.
ESD
Radiated RFI
Fast Transient
Oscillatory
HV Impulse
EMC and Environmental Type Tests
Description
Damped Oscillatory
Signal Ports
DC Line-to-Line
AC Line-to-Line
Mains Frequency
Signal Ports
Voltage
DC Line-to-Line
Ripple on DC
DC Line-to-Line
Power Supply
Dielectric Strength
Signal Ports
DC Line-to-Line
AC Line-to-Line
HV Impulse
Signal Ports
DC Line-to-Line
AC Line-to-Line
Description
Enclosure Contact
Enclosure Air
Enclosure Ports
Signal Ports
DC Line-to-Line
AC Line-to-Line
Earth Ground Ports
Signal Ports
DC Line-to-Line
AC Line-to-Line
Signal Ports
DC Line-to-Line
Test Levels
100% for 5 periods, 100% for 50 periods
2.5 kV common, 1 kV
differential mode @ 1 MHz
2.5 kV common, 1 kV
differential mode @ 1 MHz
2.5 kV common, 1 kV
differential mode @ 1 MHz
30 V Continuous, 300 V for 1 s
30 V Continuous, 300 V for 1 s
15%
2 kV (Fail-Safe Relay output)
1.5 kV
2 kV
5 kV (Fail-Safe Relay output)
5 kV
5 kV
Test Levels
± 2 kV, ± 4 kV, ± 8 kV
± 4 kV, ± 8 kV, ± 15 kV
35 V/m
± 4 kV @ 2.5 kHz
± 4 kV
± 4 kV
± 4 kV
2.5 kV common mode @ 1 MHz
2.5kV common, 1 kV differential mode @ 1 MHz
2.5 kV common, 1 kV differential mode @ 1 MHz
5 kV (Failsafe Relay)
Certification
Severity Levels
3
3
3
4
4
3
5 kV
Chapter 6
31

Hide quick links:

Advertisement

Table of Contents
loading