Transition Membrane Installation
31
Spread excess GoBoard Sealant around perimeter of membrane
as shown in illustration.
Drain Cover Installation
33
34
Make all necessary preparations for installing tile. Mix thin set
mortar per manufacturers instructions. Using a putty knife, pack
thin set mortar underneath drain cover as shown.
©2019 Johns Manville. All Rights Reserved
(continued)
32
Apply a 1/8" bead of GoBoard Sealant around perimeter of PVC
drain flange and spread with a putty knife. Once sealant skins
over, begin installing tile.
Install the drain cover assembly into the center of the drain.
The radial fins are designed to accommodate most 2" drain
cover assemblies while allowing for easy removal and
repositioning during tiling. The final height of the drain cover
needs to match the height of the installed tile.
35
Begin installing tile around drain. Using a rubber mallet, gently
level drain cover with surrounding tile if needed.