Page 1
OWNERS MANUAL SP12VSWP / SP24VSWP Submersible Well Bore Pump WARNING DO NOT use any Submflsile pump for petrol/gasoline, petroleum products.solve nts, thinners or ANY other flammable liquid with flash point below 82 °(180 °F). NOT FOR USE where flammable vapors are present.
Page 2
TABLE OF CONTENTS PAGE(S) INTRODUCTION COMPONENTS NEEDED FOR INSTALLATION PUMP CONNECTIONS & INSTALLATION INSTRUCTIONS PARTS LIST and REPLACEMENT PART KITS SUBMERSIBLE PUMP ASSEMBLY DRAWING BEFORE REQUESTING SERVICE "Helpful Hints" PUMP REMOVAL and DISASSEMBLY 9-10 PUMP RE-ASSEMBLY 11-13 APPLICATION WORKSHEET TECHNICAL SPECIFICATIONS 15-17 TOOLS REQUIRED FOR INSTALLATION &...
Page 5
4) Hook-up Safety Line (Sling) (Fig. 7). ;; ; Safety line (Sling) should be CAUTION: M . . . � . . Corrosion resistant. a) Insert safety line (Part not included) through lift plate holes. b) Fasten line with appropriate connection approximately 1-2 ft (30 - 60 cm) above the pump.
Page 8
BEFORE REQUESTING SERVICE "Helpful Hints" SYMPTOM PROBABLE CAUSE CORRECTION PUMP OPERAIBS but: 1) LOW VOLTAGE 1) CHECK POWER SUPPLY FOR PROPER VOLTAGE. NO FLOW REFER TO TECHNICAL SPECIFICATIONS (Pg. 16). FLOW REDUCED 2) NO WATER AT PUMP 2) MAKE SURE THE PUMP IS INSTALLED BELOW THE LOWEST ANTICIPATED WATER LEVEL.
Page 9
II. PUMP REMOVAL AND DISASSEMBLY For servicing using Replacement Part Kits. Warnin g : Make sure all electrical p ower is off and the Hose ( Pi p e ) is not under p ressure. Warnin g : Canister ma y be p ressurised , disassemble the p um p in p ro p er order. Follow the manual directions carefull y .
Page 10
7) Slide off the Filter Screen (Part M) (Fig. 10). 8) Remove the Canister (Part U) (Fig. 10). a) Using a 3/16" Allen Wrench remove the screws (Part V) from 3 places. b) Place one hand on the Upper Housing and the other on the Canister. Twist and pull the Assembly apart. 9) Remove Upper Housing (Part N) and Motor (Part T) (Fig.
Need help?
Do you have a question about the SP12VSWP and is the answer not in the manual?
Questions and answers