Optional Equipment; Contamination Canister - IHC Hytech CO2 User Manual

Table of Contents

Advertisement

1.3

OPTIONAL EQUIPMENT

1.3.1 CONTAMINATION CANISTER

The scrubber fan unit can be installed with a contamination canister (2.80.3963). The IHC Hytech
contamination canister removes contamination from breathing gas in enclosed environments. The
special fill of the canister removes all kind of contamination in enclosed environments such as
vomit, urine, feces and sweat.
The following chemical components are eliminated:
Urea (NH
Carbon monoxide (CO) from endogenous production
Acetone (GH
Hydrogen chloride (HCL) from vomit
Hydrogen sulphite (H
Carbonyl sulphite (OCS) from intestinal gas
Hydrogen (H) from intestinal gas
Methane (CH
Carbondisulphite (CS
Butyric acid (C
The contamination scrubber canister contains a special blend of carbon molecular sieves and a
catalyst and is stored in an air tight container. Once the container is opened and the canister is
exposed to the environment it starts to work. The canister lasts for at least 450 hours/person.
Figure 1.2
NOTE
The duration of a canister is calculated as follows:
450 divided by the number of occupants = hours of duration.
Example: A hyperbaric life boat is occupied by 18 persons. The duration of one canister is 450
divided by 18 occupants = 25 hours.
USER MANUAL CO2 SCRUBBER VERSION CS-2019-09
)
CO from urine
2
2
COCH
) metabolic and from organic waste
3
3
S) from feces/intestinal gas
2
) from intestinal gas
4
) from intestinal gas
2
H
COOH) from intestinal gas
3
1
Canister refill