Advertisement

Quick Links

I.B. CBE-IQ01
Instruction Leaflet for
Cutler-Hammer Enclosed IQ

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Cutler-Hammer Enclosed IQ and is the answer not in the manual?

Questions and answers

Summary of Contents for Eaton Cutler-Hammer Enclosed IQ

  • Page 1 I.B. CBE-IQ01 Instruction Leaflet for Cutler-Hammer Enclosed IQ...
  • Page 2 I.B. CBE-IQ01 Page 2 WARNING READ AND UNDERSTAND THE INSTRUCTIONS CONTAINED HEREINAFTER BEFORE ATTEMPTING TO UNPACK, ASSEMBLE, OPERATE, OR MAINTAIN THIS EQUIPMENT. HAZARDOUS VOLTAGES ARE PRESENT INSIDE ENCLOSURES THAT CAN CAUSE DEATH OR SEVERE PERSONAL INJURY. FOLLOW PROPER INSTALLATION, OPERATION, AND MAINTENANCE PROCEDURES TO AVOID THESE VOLTAGES.
  • Page 3: Table Of Contents

    I.B. CBE-IQ01 Page 3 SECTION 1: INTRODUCTION PRELIMINARY COMMENTS AND SAFETY PRECAUTIONS ..............Page 4 WARRANTY AND LIABILITY INFORMATION ................... Page 4 SAFETY PRECAUTIONS .......................... Page 4 SECTION 2: DESCRIPTION CATALOG NUMBER IDENTIFICATION ....................Page 5 CATALOG NUMBER EXAMPLE ........................ Page 5 SECTION 3: RECEIVING, HANDLING, AND STORAGE RECEIVING AND HANDLING ........................
  • Page 4: Section 1: Introduction

    I.B. CBE-IQ01 Page 4 1.3 SAFETY PRECAUTIONS SECTION 1: INTRODUCTION All safety codes, safety standards and/or regulations must be strictly observed in the installation, operation, and maintenance of this device. 1.1 PRELIMINARY COMMENTS AND SAFETY PRECAUTIONS CAUTION This technical document is intended to cover most aspects associated with the installation, application, operation, and maintenance of Enclosed IQ equipment.
  • Page 5: Section 2: Description

    I.B. CBE-IQ01 Page 5 The second set of characters denotes the SECTION 2: type of enclosure. DESCRIPTION ENC12 = NEMA 12 TYPE ENCLOSURE. 2.1 CATALOG NUMBER IDENTIFICATION ENC3R = NEMA 3R TYPE ENCLOSURE The Enclosed IQ catalog number provides a description The third set of characters denotes additional of the features provided with your device.
  • Page 6: Section 3: Receiving, Handling, And Storage

    I.B. CBE-IQ01 Page 6 and internal damage for reporting to the transportation SECTION 3: carrier and Cutler-Hammer, once a thorough inspection RECEIVING, HANDLING, AND STORAGE is complete. All claims should be specific as possible and include general order numbers. 3.1 RECEIVING AND HANDLING A plastic bag of instruction booklets will be found in the shipping container.
  • Page 7: Section 4: Installation And Wiring

    I.B. CBE-IQ01 Page 7 IF YOUR EQUIPMENT WAS ORDERED WITH THE SECTION 4: UNINTERRUPTABLE POWER SUPPLY OPTION, IT INSTALLATION AND WIRING WAS SHIPPED SEPARATELY. IT MUST REMAIN IN AN UPRIGHT ORIENTATION. PLACE THE UPS ON ITS MOUNTING BRACKET AFTER THE ENCLOSURE 4.1 GENERAL HAS BEEN INSTALLED.
  • Page 8: Field Wiring

    I.B. CBE-IQ01 Page 8 264 VAC OR 100-350 VDC. THE ADDITION OF AN FIG 11 - DIRECT VOLTAGE CONNECTION, ARII RELAY LIMITS CONTROL POWER TO A RANGE 4-WIRE – UP TO 600 VOLTS ONLY OF 96-144VAC OR 100-125VDC. AN ENCLOSURE FIG 12 - EXTERNAL VOLTAGE CONNECTION, OPEN EQUIPPED WITH THE UNINTERRUPTABLE POWER DELTA...
  • Page 9 I.B. CBE-IQ01 Page 9 Figure 1 Catalog Numbers: IQA6010ENC3R, IQA6010ENC12, IQA6210ENC3R, IQA6210ENC12 With seperate source. With or without graphics Effective 1/98...
  • Page 10 I.B. CBE-IQ01 Page 10 Figure 2 Catalog Numbers: IQA6030ENC3R, IQA6030ENC12, IQA6230ENC3R, IQA6230ENC12 With line power. With or without graphics Effective 1/98...
  • Page 11 I.B. CBE-IQ01 Page 11 Figure 3 Catalog Numbers: IQDP4010ENC3R, IQDP4010ENC12 With seperate source. Without I/O Effective 1/98...
  • Page 12 I.B. CBE-IQ01 Page 12 Figure 4 Catalog Numbers: IQDP4010ENC3R, IQDP4010ENC12 With line power. Without I/O Effective 1/98...
  • Page 13 I.B. CBE-IQ01 Page 13 Figure 5 Catalog Numbers: IQDP4010ENC3R, IQDP4010ENC12 With seperate source. With I/O Effective 1/98...
  • Page 14 I.B. CBE-IQ01 Page 14 Figure 6 Catalog Numbers: IQDP4010ENC3R, IQDP4010ENC12 With line power. With I/O Effective 1/98...
  • Page 15 I.B. CBE-IQ01 Page 15 Figure 7 Catalog Numbers: -P PONI option Effective 1/98...
  • Page 16 I.B. CBE-IQ01 Page 16 Figure 8 Catalog Numbers: -U UPS option Effective 1/98...
  • Page 17 I.B. CBE-IQ01 Page 17 Figure 9 Catalog Numbers: -A ARII option Effective 1/98...
  • Page 18 I.B. CBE-IQ01 Page 18 Figure 10 Direct Voltage Connection 3-wire (up to 600 volts only) Figure 11 Direct Voltage Connection 4-wire (up to 600 volts only) Effective 1/98...
  • Page 19 I.B. CBE-IQ01 Page 19 Figure 12 External voltage connection, open delta Figure 13 External voltage connection, WYE Effective 1/98...
  • Page 20 I.B. CBE-IQ01 Page 20 LINE Figure 14 Analyzer current circuit (2-CTs) Figure 15 Analyzer current circuit (3-CTs) Effective 1/98...
  • Page 21 I.B. CBE-IQ01 Page 21 LINE Figure 16 Analyzer current circuit (3-CTs, residual ground monitoring) Figure 17 Analyzer current circuit (4-CTs, residual ground monitoring) Effective 1/98...
  • Page 22 I.B. CBE-IQ01 Page 22 Figure 18 Analyzer current circuit (5-CTs) Figure 19 DP-4000 current circuit (2-CTs) Effective 1/98...
  • Page 23 I.B. CBE-IQ01 Page 23 LINE Figure 20 DP-4000 current circuit (3-CTs) Figure 21 Control power connections (note voltage on diagrams) Effective 1/98...
  • Page 24 I.B. CBE-IQ01 Page 24 Figure 22 Analyzer I/O Figure 23 DP-4000 I/O Effective 1/98...
  • Page 25 I.B. CBE-IQ01 Page 25 Figure 24 IPONI module option Figure 25 ARII Relay Option Effective 1/98...
  • Page 26: Section 5: Operation

    I.B. CBE-IQ01 Page 26 Enclosed IQ units supplied with Separate Power Source SECTION 5: Modules on the IQ devices are also equipped with a two- OPERATION position ON/OFF switch to enable switching control power on and off to the IQ device. This switch is marked CONTROL POWER DISCONNECT.
  • Page 27: Section 6: Maintenance

    I.B. CBE-IQ01 Page 27 REFER TO INSTRUCTION BOOK TD17548 IF YOUR SECTION 6: ENCLOSURE IS EQUIPPED WITH AN IQ DP-4000. MAINTENANCE REFER TO INSTRUCTION BOOKS FOR THE UNINTERRUPTABLE POWER SUPPLY AND THE ARII 6.1 MAINTENANCE ADDRESSABLE RELAY WHEN YOUR UNIT IS EQUIPPED WITH THESE DEVICES.
  • Page 28 This instruction leaflet is published solely for information purposes and should not be considered all inclusive. If further information is required, you should consult Cutler-Hammer. Sale of product shown in this literature is subject to terms and conditions outlined in appropriate Cutler-Hammer selling policies or other contractual agreement between the parties.

Table of Contents