Zennio KLIC-MITTE User Manual

Knx - it terminal gateway for mitsubishi electric ecodan units

Advertisement

KLIC-MITTE
KNX - IT Terminal Gateway for
Mitsubishi Electric Ecodan Units
ZCLMITTE
Application program version: [1.0]
User manual edition: [1.0]_a
www.zennio.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KLIC-MITTE and is the answer not in the manual?

Questions and answers

Summary of Contents for Zennio KLIC-MITTE

  • Page 1  KLIC-MITTE KNX - IT Terminal Gateway for Mitsubishi Electric Ecodan Units ZCLMITTE Application program version: [1.0] User manual edition: [1.0]_a www.zennio.com...
  • Page 2: Table Of Contents

    KLIC-MITTE CONTENTS Contents ........................... 2 Introduction ........................3 KLIC-MITTE ........................3 Installation ........................4 Start-Up and Power Loss ....................5 Configuration ........................6 General ........................6 ECODAN Gateway......................8 2.2.1 Configuration ....................... 8 2.2.2 Initial Configuration .................... 12 2.2.3 Error Handling ....................15 Inputs .........................
  • Page 3: Introduction

    KLIC-MITTE 1 INTRODUCTION KLIC-MITTE KLIC-MITTE from Zennio is a new gateway that provides full-duplex communication between the KNX home automation system and Mitsubishi Electric Ecodan air- conditioning and hot water management systems through the IT Terminal interface. Because of this bidirectional communication, the air conditioning system can be controlled from the home automation system in the same manner as it is through its own controls.
  • Page 4: Installation

    5. KNX connector Figure 1. Element scheme KLIC-MITTE connects to the KNX bus via the corresponding built-in terminal (5). Once the device is provided with power from the KNX bus, both the physical address and the KLIC-MITTE application program can be downloaded.
  • Page 5: Start-Up And Power Loss

    In addition, certain parameterisations made in the device can be ignored. For detailed information about the technical features of KLIC-MITTE, as well as on security and installation procedures, please refer to the device Datasheet, bundled in the device packaging and also available at http://www.zennio.com.
  • Page 6: Configuration

    The “General” screen is shown in the first place, containing the following parameters: Figure 3. General Ecodan Gateway [enabled] : entails all functions specific to KLIC-MITTE, relating to communication with the Ecodan unit and management of the climate and hot water control system. For more information, see section 2.2.
  • Page 7 KLIC-MITTE Figure 4. Heartbeat Note: the first sending after download or bus failure takes place with a delay of up to 255 seconds, to prevent bus overload. The following sendings match the period set. Regardless of the above parameters, the following objects are available by default: “[General] On/Off”...
  • Page 8: Ecodan Gateway

    KLIC-MITTE ECODAN GATEWAY 2.2.1 CONFIGURATION KLIC-MITTE allows controlling and monitoring an Ecodan unit. Through the KNX bus, commands to control the following basic functions can be sent to KLIC-MITTE: On/Off switch of the Ecodan unit. Climate control and supervision:  Climate operation and permission status: allows to know if the unit is working and if it is authorised.
  • Page 9  DHW operating and permission status: allows to discern when the unit is heating water and when it is not and if it is authorised. On the other hand, KLIC-MITTE allows the configuration of the following advanced functions: Advanced Modes: allows to enable objects to activate the general Holiday Mode, and the Economy and Forced Modes in the DHW system.
  • Page 10 KLIC-MITTE In addition, KLIC-MITTE provides an error management function (see section 2.2.33), which allows sending messages to the KNX bus in case the A/C unit reports any errors. ETS PARAMETRIZATION The “Configuration” tab under Ecodan Gateway provides the following parameters: Figure 5.
  • Page 11 KLIC-MITTE  “[Climate] [Zone X] Temperature Setpoint (Status)”: allows to know the setpoint temperature at which the machine is working.  “[Climate] [Zone X] Temperature Control Mode (Status)”: 1-Byte object that allows to know the temperature control mode status. The...
  • Page 12: Initial Configuration

    Configuration” in the left menu. For more information, see section 2.2.2. 2.2.2 INITIAL CONFIGURATION The custom initial configuration allows setting the desired status that KLIC-MITTE will send the unit after downloading or restarting the device. This status is defined in terms of On/Off, domestic home water and climate.
  • Page 13 KLIC-MITTE ETS PARAMETRISATION After selecting “Custom” for the Initial Configuration option under the “Configuration” tab (see section 2.2.1), a new tab named Initial Configuration is displayed with the following parameters: Figure 6. Ecodan Gateway. Initial configuration. GENERAL On/Off [Last / On / Off].
  • Page 14 KLIC-MITTE Note: Initial configuration of the ACS modes will only available if advanced modes are enabled in “Configuration” tab (see section 2.2.1). Setpoint [disabled/enabled]:  Value:  Last: only available if Setpoint parameter remains disabled.  40…60 ºC: concrete value of the set temperature.
  • Page 15: Error Handling

    KLIC-MITTE 2.2.3 ERROR HANDLING KLIC-MITTE is capable of managing two error types that do not entail any previous parameter configuration: Communication o internal error: error in the communication process between KLIC-MITTE and the Ecodan unit. In case KLIC-MITTE is unable to connect to the machine, it stops responding or returns wrong traces, the device will send the 1-Bit object “[General] Internal...
  • Page 16: Inputs

    Zennio website (www.zennio.com). 2.3.3 MOTION DETECTOR It is possible to connect motion detectors from Zennio to the input ports of KLIC-MITTE. Please refer to the “Motion Detector” user manual, available in the KLIC-MITTE product section, at the Zennio website (www.zennio.com) for detailed information about the functionality and the configuration of the related parameters.
  • Page 17: Logic Functions

    KNX bus, and to send the results through other communication objects specifically enabled for this purpose. KLIC-MITTE can implement up to 10 different and independent functions, each of them entirely customisable and consisting in up to 4 consecutive operations each.
  • Page 18: Annex I. Communication Objects

    KLIC-MITTE ANNEX I. COMMUNICATION OBJECTS “Functional range” shows the values that, with independence of any other values permitted by the bus according to the object size, may be of any use or have a particular meaning because of the specifications or restrictions from both the KNX standard or the application program itself.
  • Page 19 KLIC-MITTE 34, 40 1 Bit C - - W - DPT_Enable [Ix] Input Lock 0 = Unlock; 1 = Lock 1 Bit C T - - - DPT_Switch [Ix] [Short Press] 0 Sending of 0 1 Bit C T - - -...
  • Page 20 KLIC-MITTE (Integer) [Ix] [Short Press] Constant Value 1 Byte C T - - - DPT_Scaling 0% - 100% 0% - 100% (Percentage) [Ix] [Short Press] Constant Value 2 Bytes C T - - - DPT_Value_2_Ucount 0 - 65535 0 - 65535...
  • Page 21 KLIC-MITTE 1 Bit C T - - - DPT_Switch [Ix] [Long Press] Light Off Sending of 0 (Off) 1 Bit C T - W - DPT_Switch [Ix] [Long Press] Light On/Off Switching 0/1 1 Byte C T - - - DPT_SceneControl 0-63;...
  • Page 22 KLIC-MITTE 96, 101 1=Comfort 63, 68, 73, 92, 2=Standby Auto, Comfort, Standby, Economy, 1 Byte C T R - - DPT_HVACMode [Ix] [Cx] Detection State (HVAC) 97, 102 3=Economy Building Protection 4=Building Protection 64, 69, 74, 93, 1 Bit C T R - -...